FUJI错误代码查询.pdf - 第1599页

------------------------------ Code: 1D2BD080 Display: Same as code. Used by: Cause: The pickup position error (in the Y direction) is excessive. Remedy: Check the manner in which parts are supplied. --------------------…

100%1 / 5282
Code: 1D2BC1??
Display: Same as code.
Used by:
Cause: No leads could be found on the lower side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2BC2??
Display: Same as code.
Used by:
Cause: No leads could be found on the right side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2BC3??
Display: Same as code.
Used by:
Cause: No leads could be found on the upper side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2BC4??
Display: Same as code.
Used by:
Cause: The left edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D2BC5??
Display: Same as code.
Used by:
Cause: The lower edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D2BC6??
Display: Same as code.
Used by:
Cause: The right edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D2BC7??
Display: Same as code.
Used by:
Cause: The upper edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D2BD000
Display: Same as code.
Used by:
Cause: The pickup position error (in the X direction) is excessive.
Remedy: Check the manner in which parts are supplied.
第 1598 页
------------------------------
Code: 1D2BD080
Display: Same as code.
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D2BD100
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D2BE???
Display: Same as code.
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions. In particular, check for soiling of the nozzle, and make sure that the
CCD level is correct.
------------------------------
Code: 1D2BF???
Display: Same as code.
Used by:
Cause: There is a logical error in the processing program. The part cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the part.
Remedy: Check the Part data.
------------------------------
Code: 1D2C0002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is too large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D2C8002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D2C8100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D2C8110
第 1599 页
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D2C8111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D2C8112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D2C8113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D2C8114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D2C8115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D2C8120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D2C8121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
第 1600 页