FUJI错误代码查询.pdf - 第2180页

Remedy: Input an element with 5 or more leads. ------------------------------ Code: 230A3206 Display: No leads were found. Used by: PDW Cause: Lead pins could not be recognized in semi-automatic input. Remedy: Specify th…

100%1 / 5282
Display: There is Position seek line whose edge position compensation is incomplete.
Used by: PDW
Cause: The edge positions have not been compensated after setting the Position seek lines.
Remedy: Compensate the position of the edges.
------------------------------
Code: 230A3108
Display: There is an Inspection seek line whose edge position compensation is incomplete.
Used by: PDW
Cause: The edge positions have not been compensated after setting the Inspection seek lines.
Remedy: Compensate the position of the edges.
------------------------------
Code: 230A3109
Display: Recognition error.
Used by: PDW
Cause: Inspection failed.
Remedy: Carry out the seek line settings again.
------------------------------
Code: 230A310A
Display: Edge position compensation was not successful for some seek lines.
Used by: PDW
Cause: No edges were found above the seek lines for finding edges.
Remedy: Move the edge finding seek lines to positions where they cross over edges.
------------------------------
Code: 230A3201
Display: Recognition error.
Used by: PDW
Cause: An error occurred during image recognition.
Remedy: Input element data that can be recognized.
------------------------------
Code: 230A3202
Display: Maximum input level reached.
Used by: PDW
Cause: More than 128 lead elements have been input.
Remedy: Delete the current element data and specify new element data.
------------------------------
Code: 230A3203
Display: Size could not be determined.
Used by: PDW
Cause: The average width of the leads being edited is 0.
Remedy: Input element data that can be recognized.
------------------------------
Code: 230A3204
Display: No element data.
Used by: PDW
Cause: No elements have been input.
Remedy: Input element data.
------------------------------
Code: 230A3205
Display: Requires 1 or more elements with 5 or more leads.
Used by: PDW
Cause: There are no elements with 5 or more leads.
第 2179 页
Remedy: Input an element with 5 or more leads.
------------------------------
Code: 230A3206
Display: No leads were found.
Used by: PDW
Cause: Lead pins could not be recognized in semi-automatic input.
Remedy: Specify the correct recognition range.
------------------------------
Code: 230A3207
Display: Unexpected error
Used by: PDW
Cause: An unidentified error occurred before recognition.
Remedy: Check that the element data and template are correct.
------------------------------
Code: 230A3301
Display: Recognition error.
Used by: PDW
Cause: An error occurred during image recognition.
Remedy: Input element data that can be recognized.
------------------------------
Code: 230A3302
Display: Maximum input level reached.
Used by: PDW
Cause: More than 128 ball elements have been input.
Remedy: Delete the current element data and specify new element data.
------------------------------
Code: 230A3303
Display: Unable to adjust pitch.
Used by: PDW
Cause: The average pitch X/Y of the values being edited is 0.
Remedy: Input element data that can be recognized.
------------------------------
Code: 230A3304
Display: No element data.
Used by: PDW
Cause: No elements have been input.
Remedy: Input element data.
------------------------------
Code: 230A3305
Display: Requires an element with 2 or more adjacent balls.
Used by: PDW
Cause: Recognition/compensation cannot be completed because there are no recognizable adjacent balls
in the element data.
Remedy: Check that the element data is correct.
------------------------------
Code: 230A3306
Display: Unexpected error
Used by: PDW
Cause: An unidentified error occurred before recognition.
Remedy: Check that the element data and template are correct.
------------------------------
第 2180 页
Code: 230A3307
Display: Total number of balls must be at least 12.
Used by: PDW
Cause: The number of balls specified in element data is less than 12.
Remedy: Input element data to increase the number of balls to 12 or more.
------------------------------
Code: 230A3308
Display: Requires an element with 2 or more balls.
Used by: PDW
Cause: None of the input elements have 2 or more balls.
Remedy: Input an element with 2 or more balls.
------------------------------
Code: 230A4000
Display: Cannot perform vision test.
Used by: PDW
Cause: Failed to compile the edited template.
Remedy: Carry out the template editing again.
------------------------------
Code: 230A4001
Display: Cannot read Debug Information.
Used by: PDW
Cause: Could not read one of either the PDS, image, template or debug data files.
Remedy: Check that you have all the files and they are all in working order.
------------------------------
Code: 230A4002
Display: Filename has invalid characters.
Used by: PDW
Cause: The conditions file name has invalid characters.
Remedy: Change the file name, removing invalid characters.
------------------------------
Code: 31003110
Display: Command_line transmission error
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
Cause: Command line transmission error.
Remedy: Press the [Reset] button. Send the board type information from the machine to the LMS again.
------------------------------
Code: 31003111
Display: SCH. Check DATA TABLE on LMS
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
Cause: There is no data in the production schedule table.
Remedy: Check the LMS production schedule table.
------------------------------
Code: 31003112
Display: DATA Check DATA TABLE on LMS
Used by: CP3,CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP6,IP1,IP3,Q
P242,QP201
第 2181 页