FUJI错误代码查询.pdf - 第2135页
Code: 2300E57C Display: When using Vision Type 20, the first and second Element side settings must be specified as either 0 and 2, or, 1 and 3. Used by: Cause: Vision Type 20 cannot be used for parts where the "Elem…
Used by:
Cause: Vision Type 20 does not allow a "Lead Quantity" setting value of 6 or higher.
Remedy: Either change the Vision Type, or change the "Lead Quantity" setting to a value of 5 or less.
------------------------------
Code: 2300E576
Display: Lead Width is not defined.
Used by:
Cause: A "Lead Width" setting of "0" existed where the Result was other than 128 for the "Element" item
of a Vision Type 230 or 231 part.
Remedy: Specify "Lead Width" settings at lines where the Result is other than 128 for the "Element" item
of a Vision Type 230 or 231 part.
------------------------------
Code: 2300E577
Display: Lead Quantity is not defined.
Used by:
Cause: A "Lead Quantity" setting of "0" existed where the Result was other than 128 for the "Element"
item of a Vision Type 230 or 231 part.
Remedy: Specify "Lead Quantity" settings at lines where the Result is other than 128 for the "Element"
item of a Vision Type 230 or 231 part.
------------------------------
Code: 2300E578
Display: 128 cannot be set at the first line of Result.
Used by:
Cause: A setting of "128" exists at the first Result line for the Element item of a Vision Type 230 or 231
part.
Remedy: Specify a setting other "128" at the first Result line for the Element item of a Vision Type 230 or
231 part.
------------------------------
Code: 2300E579
Display: Result is set to 128 for 2 consecutive element lines.
Used by:
Cause: A setting of "128" exists at two consecutive Result lines for the Element item of a Vision Type 230
or 231 part.
Remedy: Do not specify a "128" setting at two consecutive Result lines for the Element item of a Vision
Type 230 or 231 part.
------------------------------
Code: 2300E57A
Display: When using Vision Type 230 or 231, set the P Pattern to 1 or 2.
Used by:
Cause: For Vision Types 230 and 231, vision processing is only possible when the "P Pattern" is set to 1
or 2.
Remedy: For Vision Types 230 and 231, set the "P Pattern" to 1 or 2.
------------------------------
Code: 2300E57B
Display: 2 Element lines are required for Vision Type 20.
Used by:
Cause: For Vision Type 20, vision processing is only possible when the "Element" setting occupies 2 or
more lines.
Remedy: Specify 2 lines for the "Element" setting. If the Element sides are not facing each other, change
the Vision Type.
------------------------------
第 2134 页
Code: 2300E57C
Display: When using Vision Type 20, the first and second Element side settings must be specified as either
0 and 2, or, 1 and 3.
Used by:
Cause: Vision Type 20 cannot be used for parts where the "Element" first and second line sides are not
facing each other (not [0-2] or [1-3]).
Remedy: For Vision Type 20, set so that the "Element" first and second line sides are facing each other
([0-2] or [1-3]).
------------------------------
Code: 2300E57D
Display: Vision Type 230, 231 cannot be used to process BGAs with less than 12 balls.
Used by:
Cause: Vision Type 230 and 231 vision processing is not possible for BGA parts with fewer than 12 balls.
Remedy: Set the Element's "Lead Quantity" so that the total number of balls is 12 or more. If the total
number of balls is fewer than 12, use Vision Type 18.
------------------------------
Code: 2300E57E
Display: Specify Lead Pitch if the Lead Quantity is 2 or greater.
Used by:
Cause: A "Lead Pitch" setting of "0" existed when the "Lead Quantity" setting was 2 or more.
Remedy: When the "Lead Quantity" setting is 2 or more, specify a "Lead Pitch" setting.
------------------------------
Code: 2300E57F
Display: When using Vision Type 10, the Body Length (X) should be the same size or larger than the Body
Width (Y).
Used by:
Cause: When using Vision Type 10, the "Body Length (Y) dimension exceeded the "Body Length (X)"
dimension.
Remedy: When using Vision Type 10, specify a "Body Length (X) dimension which is larger than the "Body
Length (Y)" dimension.
------------------------------
Code: 2300E580
Display: When using Vision Type 100 or 130, the Lead Quantity must be 5 or greater for the first element.
Used by:
Cause: When using Vision Type 100 or 130, the "Element's" first line "Lead Quantity" was less than 5.
Remedy: When using Vision Types 100 and 130, specify the "Element's" first line "Lead Quantity" as 5 or
more.
------------------------------
Code: 2300E581
Display: The value set for Stand Off height is higher than or equal to the Part Height.
Used by:
Cause: The value set for Stand Off height is higher than or equal to the Part Height.
Remedy: Enter a value lower than the Part Height.
------------------------------
Code: 2300E582
Display: Parts using vision type 230 or 231 require at least one element with lead quantity of two or more.
(Excluding the second row of data in the matrix display.)
Used by:
Cause: The element data for parts using vision type 230 or 231 does not have an element with two or
more leads.
Remedy: When using vision type 230 or 231, create at least one element with lead quantity of two or
第 2135 页
more.
------------------------------
Code: 2300E583
Display: The specified part size exceeds the scanning range (Body Length (X):5 mm or less, Body Width
(Y):4 mm or less) that can be handled by the camera for Vision Type 10.
Used by:
Cause: The maximum part dimensions that may be specified when using vision type 10 are 5 mm for the
body length (X) and 4 mm for the body width (Y). If the specified part size exceeds these dimenhe part
may not be found or accuracy may be negatively affected.
Remedy: When using vision type 10, only use parts with maximum dimensions of 5 mm for the body
length (X), and 4 mm for the body width (Y). For larger parts, create the part data using vision type 18.
------------------------------
Code: 2300E584
Display: For Vision Type 124, the [Element] setting must occupy either 2 or 4 lines.
Used by:
Cause: For Vision Type 124, vision processing is only possible when the "Element" setting occupies either
2 or 4 lines.
Remedy: Specify either 2 or 4 lines for the "Element" setting.
------------------------------
Code: 2300E585
Display: For Vision Type 180, the total number of leads in [Lead Quantity] for the entire element must be
2, 3, or 4
Used by:
Cause: For Vision Type 180, the total number of leads in "Lead Quantity" for the entire element must be
2, 3, or 4.
Remedy: When using Vision Type 180, set the values for "Lead Quantity" so that the sum of all leads for
the element equals 2, 3, or 4.
------------------------------
Code: 2300E586
Display: 5 or more leads do not exist, or the part exceeds the scan range that can be handled by the
camera.
Used by:
Cause: 5 or more leads are required. Where 5 or more leads exist, and the part is picked up at the
revolver center, the part exceeds the scan range that can be handled by the camera.
Remedy: Create the part data using vision type 18 or 20.
------------------------------
Code: 2300E587
Display: The settings at Scan Area X and Scan Area Y are outside the range that can be handled by the
Front(Rear) camera (short side: **.***; long side: **.***).
Used by:
Cause: The settings at "Scan Area X" and "Scan Area Y" are outside the range that can be handled by the
Front(Rear) camera (short side: %.3f; long side: %.3f).
Remedy: Compare "Scan Area X" with "Scan Area Y." The one with the lower value should be set to be
shorter than the short side of the field of view, and the one with the higher value should be set to be
shorter than the long side.
------------------------------
Code: 2300E588
Display: 2 or more Element lines are required for Vision Type 20.
Used by:
Cause: For Vision Type 20,vision processing is only possible when the "Element"setting occupies 2 or
more lines.