Remedy: Check the sensor cable continuity, and replace the cable if necessary. ------------------------------ Code: 121???42 Display: Coplanarity error(NP2,QP3) Used by: QP242,NP2,QP3 Cause: Communication with "Sens…
------------------------------
Code: 121???21
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: A command sequence error occurred. The command could not be executed at the LLL board.
Remedy: Restart the system, and repeat the operation from the beginning.
------------------------------
Code: 121???22
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Insufficient data error. LLL board calculation ended in failure due to insufficient data. Lead
measurement was not performed, and no pulse was received from the encoder. A coplanarity calculation
was attempted after scanning 1 side.
Remedy: Set the Lead-Length (in part data) as accurately as possible. Increase the Scan Offset to permit
measurement of the full length of the lead. Lead coplanarity checks are possible for SOIC or QFP parts.
------------------------------
Code: 121???23
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Parameter error. The received data is invalid for the LLL..
Remedy: Check the Coplanarity item in part data.
------------------------------
Code: 121???24
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Invalid command. The attempted command is invalid for the LLL..
Remedy: Execute a reset start.
------------------------------
Code: 121???30
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Serial communication "receive overrun" error.
Remedy: Restart the system and repeat the operation from the beginning.
------------------------------
Code: 121???31
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Serial communication "parity" error.
Remedy: Restart the system and repeat the operation from the beginning.
------------------------------
Code: 121???32
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Serial communication "framing" error.
Remedy: Restart the system and repeat the operation from the beginning.
------------------------------
Code: 121???40
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Communication with "Sensor 0 EEPROM Readback Error sensor 0" is not occurring. Sensor
cable is severed or disconnected.
第 861 页
Remedy: Check the sensor cable continuity, and replace the cable if necessary.
------------------------------
Code: 121???42
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Communication with "Sensor Synchronization Error sensor 0" is not occurring. Sensor cable is
severed or disconnected.
Remedy: Check the sensor cable continuity, and replace the cable if necessary.
------------------------------
Code: 121???50
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: "Expecting FIFO Empty VME" board failure.
Remedy: Turn the power off and execute a reset start.
------------------------------
Code: 121???60
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Laser beam was uninterrupted at the wrong point, or was never interrupted.
Remedy: Check the sensor mount position and the lead measurement position. If this occurs during lead
measurement, verify that the part data "Lead Length" is set as accurately as possible. Increase the
"lead_offset" for the "Coplanarity" item in part data to ensure that the full length of the lead is measured.
------------------------------
Code: 121???61
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Laser beam was interrupted at the wrong point, or is still interrupted.
Remedy: Verify that no foreign matter or parts are adhering to the sensor. Verify that the body is not
being measured instead of the lead during lead measurements.
------------------------------
Code: 121???70
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Coplanarity calculation results indicate a lead height above the "Coplanarity Tolerance" height
(part data).
Remedy: Check for raised part leads. Verify that the "Coplanarity Tolerance" value (part data) is not too
small.
The coplanarity check result can be viewed at the [Coplanarity] screen. (QP3)
However, only the most recently performed check for each holder can be viewed. (QP3)
The [Coplanarity] screen can be reached through the following path: [Main] -[Maintenance] -
[Coplanarity]. (QP3)
------------------------------
Code: 121???71
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Linearity calculation results indicate a lead which is outside the "Linear Tolerance" plane (part
data).
Remedy: Check for bent part leads. Verify that the "Linear Tolerance" value (part data) is not too small.
The coplanarity check result can be viewed at the [Coplanarity] screen. (QP3)
However, only the most recently performed check for each holder can be viewed. (QP3)
The [Coplanarity] screen can be reached through the following path: [Main] -[Maintenance] -
第 862 页
[Coplanarity]. (QP3)
------------------------------
Code: 121???72
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The lead coplanarity check indicates that the number of measured leads does not match the
number of leads specified in part data.
Remedy: Check for bend leads. Verify that the measurement is not occurring too close to the lead ends.
Verify that the following part data settings are correct: Lead-Length, Lead-Width, Body-Length, Body-
Width.
The coplanarity check result can be viewed at the [Coplanarity] screen. (QP3)
However, only the most recently performed check for each holder can be viewed. (QP3)
The [Coplanarity] screen can be reached through the following path: [Main] -[Maintenance] -
[Coplanarity]. (QP3)
------------------------------
Code: 121???73
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The lead coplanarity check cannot occur because the part pickup position is too close to the
leads. (Nozzle / sensor interference could occur if performed.)
Remedy: Verify that the part size and lead length are suitable for a lead coplanarity check. Verify that the
pickup position is not too close to the part corner.
------------------------------
Code: 12100081
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错。
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据,并将它送至弊社。
------------------------------
Code: 12100082
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错。
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据,并将它送至弊社。
------------------------------
Code: 12100083
Display: 不能识别引脚
Used by: XP241,XP341,XP242
Cause: 由于某种原因,不能进行粗定位。
Remedy: 请更换发生错误的元件或确认元件与元件数据是否吻合。
特别要确认要素数据和Stand Off 是否正确。
如元件数据正确时,请调查吸取状态是否良好、影像的明亮度是否有问题、焦距是否对准、以及是否摄有污垢。
------------------------------
Code: 12100084
Display: Element的引脚数比设定值要多
Used by: XP241,XP341,XP242
Cause: 引脚根数检查出错。
Remedy: 请更换发生错误的元件或确认元件数据是否正确。特别要确认元件数据的引脚数是否正确。如元件数据正确
时,请调查吸取状态是否良好、影像的明亮度是否有问题、焦距是否对准、以及是否摄有污垢。
------------------------------
Code: 12100085