FUJI错误代码查询.pdf - 第662页

------------------------------ Code: 12066B00 Display: Precise pressure control error Used by: NP-2, QP-3 Cause: Measurement error. The acquired deviation is outside the acceptable range. Remedy: Check for damage to the …

100%1 / 5282
LD_ERR 12066A05
Used by: QP132
Cause: There was a failure with the data carrier page toggle write function.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A06
Display: ID_NEXT_PAGE_ERR
LD_ERR 12066A06
Used by: QP132
Cause: There was a failure with the page data write function.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A07
Display: CARRIER DATA ERROR
ID Reader Error: 12066A07
Used by: QP132
Cause: The pallet's carrier data at the landing station is corrupt.
Remedy: The pallet's data carrier at the landing station has corrupted information. Remove all pallets
and reload them.
------------------------------
Code: 12066A08
Display: No carrier at landing station.
ID Reader Error: 12066A08
Used by: QP132
Cause: A carrier is at the landing station when it should not be there or, when a carrier is expected for
the loading of a pallet, there is no carrier present.
Remedy: Check that the connection between the landing station head and ID controller, as well as the
connection between the ID controller and the machine data port, is good. When a pallet is present when
none should be, remove and reload all pallets.
------------------------------
Code: 12066A09
Display: JEDEC tray type error!
Used by: QP301
Cause: A JEDEC tray feeder of the wrong type has been attached.
Remedy: Attach a JEDEC tray feeder of the correct type.
------------------------------
Code: 12066A0A
Display: Lifter plate error!
Used by: QP301
Cause: An atempt was made to unclamp the package with the lifter plate in place.
Remedy: Remove the lifter plate.
------------------------------
Code: 12066A0B
Display: Nozzle Position Error
Used by: QP301
Cause: Nozzle is not set to the right holder.
Remedy: Check the nozzle positions and make changes as required.
第 661 页
------------------------------
Code: 12066B00
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Measurement error. The acquired deviation is outside the acceptable range.
Remedy: Check for damage to the cylinder head, wiring errors, electro-pneumatic regulator errors, and
pressure measurement unit errors.
------------------------------
Code: 12066B01
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Compensation cannot be calculated due to a precise pressure Proper data error. Precise pressure
calibration may not have been performed.
Remedy: Perform precise pressure calibration for the target holder(s).
------------------------------
Code: 12066B02
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Precise pressure controller load range error. Load instruction cannot be issued.
Remedy: Correct the maximum and minimum load range values in the machine configuration file, and
then calibrate the pressure.
------------------------------
Code: 12066B03
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Incorrect value issued to the pressure controller.
Remedy: Perform precise pressure calibration for the target holder(s).
------------------------------
Code: 12066B04
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: An error occurred at the precise pressure controller.
Remedy: Reboot the machine, and inspect the pressure controller if the problem persists.
------------------------------
Code: 12066B05
Display: Pressure measurement unit error.
Used by: NP-2, QP-3
Cause: An error occurred at the pressure measurement unit.
Remedy: Reboot the machine, and inspect the pressure measurement unit if the problem persists.
------------------------------
Code: 12066B06
Display: RADDS error
Machine type: QP3
Used by:
Cause: The Machine memory condition differs to that of RADDS.
Remedy: Remove the die using the die removal command.
------------------------------
Code: 12066B07
Display: RADDS error
Machine type: QP3
Used by:
第 662 页
Cause: The die cannot be picked becasue there is no die pick information.
Remedy: Remove the die using the die removal command.
------------------------------
Code: 12066B08
Display: RADDS error
Machine type: QP3
Used by:
Cause: Some die may still remain on RADDS.
If production is continued any remaining die will fall from the shuttle or inverter.
Remedy: Remove any remaining die from the shuttle and inverter.
Execute the following commands to delete any die references from the RADDS memory.
[RADDS Commands]
1. Close the COMMAND READY window and select "JobInfo" from the main window.
2. Select "Die in Proc" from the ID_DLG_JOB_INFO dialog box.
3. Select "Flush" from the Die in process dialog box.
------------------------------
Code: 12066B09
Display: Serial communication error
Used by: NP2,QP3
Cause: Serial communication error.
Remedy: Reset the part power supply.
------------------------------
Code: 12066C00
Display: RADDS error
Used by: NP2,QP3
Cause: Communication problem with RADDS.
Remedy: Check the RADDS connection.If the connection is OK, reset the RADDS power supply.
------------------------------
Code: 12066C01
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS error stop.
Remedy: Clear the error status as instructed on the RADDS screen.
------------------------------
Code: 12066C02
Display: RADDS error
Used by: NP2,QP3
Cause: Parts out condition at RADDS.
Remedy: Supply RADDS with the required wafer.
------------------------------
Code: 12066C03
Display: RADDS error
Used by: NP2,QP3
Cause: Wafers are being supplied to RADDS.
Remedy: Supply RADDS with wafers, then close the wafer door.
------------------------------
Code: 12066C04
Display: RADDS error
Used by: NP2,QP3
Cause: Temporary stop status at RADDS.
Remedy: Clear the temporary stop status as instructed on the RADDS screen.