Display: "Sensor logical alarm: cleaner shift" (GP6) Used by: GP6 Cause: The cleaner shift forward end (X07C) and retract end (X07D) sensors have either both turned on or both turned off at the same time. Remed…
making contact with the board or the PPC.
------------------------------
Code: 12056008
Display: Certify to B_mark
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The B-marks that the machine read are all considered as "skip".
Remedy: Ensure that the B-marks are in the specified position of the program. After restarting the
machine, the B-marks arereread. Press the unload button to unload the board.
------------------------------
Code: 12056009
Display: "Pal Transport Err On R.Conv"
Used by: CP652C
Cause: The rear conveyor pallet arrival sensor has failed to indicate the arrival of a pallet within the
specified time.
Remedy: Make sure that the pallet is not stuck on the rear conveyor, and that nothing is obstructing
pallet movement.If there is no obstruction, perform an I/O check on the pallet arrival check sensor
(X09E), and adjust the sensor as necessary.
------------------------------
Code: 1205600A
Display: "Cleaner sensor logical alarm"
Used by: GP6
Cause: There is a logic error in input from the cleaner position check sensors.
Remedy: The logic error is in the following sensors: X05C:CLNR ZERO POS, X03E:CLNR NEAR CHK, and
X07C:CLNR SHIFT RET.In the case of a double-side cleaner, these three sensors should never all turn on
at once. The error may be caused by a wiring error or a sensor malfunction. Check the sensors and adjust
as necessary.
------------------------------
Code: 1205600B
Display: "Sensor logical alarm: upper cleaner head" (GP6)
Used by: GP6
Cause: The upper cleaner head open limit (X07C) and close limit (X07D) sensors have either both turned
on or both turned off at the same time.
Remedy: Check the upper cleaner head open limit and close limit sensors, and adjust them as necessary.
------------------------------
Code: 1205600C
Display: "Sensor logical alarm: lower cleaner head" (GP6)
Used by: GP6
Cause: The lower cleaner head open limit (X05A) and close limit (X05B) sensors have either both turned
on or both turned off at the same time.
Remedy: Check the lower cleaner head open limit and close limit sensors, and adjust them as necessary.
------------------------------
Code: 1205600D
Display: "Sensor logical alarm: cleaner notch" (GP6)
Used by: GP6
Cause: The cleaner notch sensors (X05D and X05E) sensors have either both turned on or both turned
off at the same time.
Remedy: If the machine supports a double-side cleaner, check and adjust the sensors for the notch that
connects the cleaner to the S-axis. If the machine uses a single-side cleaner, check and adjustthe sensors
for the notch that connects the cleaner to the cleaner shift.
------------------------------
Code: 1205600E
第 575 页
Display: "Sensor logical alarm: cleaner shift" (GP6)
Used by: GP6
Cause: The cleaner shift forward end (X07C) and retract end (X07D) sensors have either both turned on
or both turned off at the same time.
Remedy: Check the cleaner shift forward end and retract end sensors, and adjust them as necessary.
------------------------------
Code: 1205600F
Display: "M/C err Sensor SQG Holder" (GP6 w/single squeegee), "M/C err Sensor
SQG F" (front squeegee on double-squeegee GP6), "M/C err Sensor SQG R"
(rear squeegee on double-squeegee GP6)
Used by: GP6
Cause: The squeegee holder upper limit and lower limit check sensors (X070 and X071 for either a single
squeegee or squeegee F, and X078 and X079 for squeegee R) have either both turned on or both turned off
at the same time.
Remedy: Check the squeegee holder upper limit and lower limit check sensors, and adjust them as
necessary.
------------------------------
Code: 12056010
Display: "M/C err Sensor Top Cleaner Connected"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056011
Display: "Sensor Logic Error Conveyor Width Clutch"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056012
Display: "Sensor Logic Error Push Plate"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056013
Display: "M/C err Sensor Holder **(UPorDOWN)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056014
Display: "Sensor Logic Error SQG Open/Close"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
第 576 页
------------------------------
Code: 12056015
Display: "Sensor Logic Error Solder Pusher"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056016
Display: "M/C err Sensor Cleaner Released"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056017
Display: "M/C err Sensor Clnr Head **** (Open or Close)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056018
Display: "Sensor Logic Error Replenish *** Wrn (BTM or TOP)"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056019
Display: "Sensor Logic Error Screen Clamp Top"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601A
Display: "Sensor Logic Error Solder Supply UP/DN"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601B
Display: "Sensor Logic Error Mask Supprt"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601C