Display: "Sensor logical alarm: cleaner shift" (GP6) Used by: GP6 Cause: The cleaner shift forward end (X07C) and retract end (X07D) sensors have either both turned on or both turned off at the same time. Remed…

100%1 / 5282
making contact with the board or the PPC.
------------------------------
Code: 12056008
Display: Certify to B_mark
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The B-marks that the machine read are all considered as "skip".
Remedy: Ensure that the B-marks are in the specified position of the program. After restarting the
machine, the B-marks arereread. Press the unload button to unload the board.
------------------------------
Code: 12056009
Display: "Pal Transport Err On R.Conv"
Used by: CP652C
Cause: The rear conveyor pallet arrival sensor has failed to indicate the arrival of a pallet within the
specified time.
Remedy: Make sure that the pallet is not stuck on the rear conveyor, and that nothing is obstructing
pallet movement.If there is no obstruction, perform an I/O check on the pallet arrival check sensor
(X09E), and adjust the sensor as necessary.
------------------------------
Code: 1205600A
Display: "Cleaner sensor logical alarm"
Used by: GP6
Cause: There is a logic error in input from the cleaner position check sensors.
Remedy: The logic error is in the following sensors: X05C:CLNR ZERO POS, X03E:CLNR NEAR CHK, and
X07C:CLNR SHIFT RET.In the case of a double-side cleaner, these three sensors should never all turn on
at once. The error may be caused by a wiring error or a sensor malfunction. Check the sensors and adjust
as necessary.
------------------------------
Code: 1205600B
Display: "Sensor logical alarm: upper cleaner head" (GP6)
Used by: GP6
Cause: The upper cleaner head open limit (X07C) and close limit (X07D) sensors have either both turned
on or both turned off at the same time.
Remedy: Check the upper cleaner head open limit and close limit sensors, and adjust them as necessary.
------------------------------
Code: 1205600C
Display: "Sensor logical alarm: lower cleaner head" (GP6)
Used by: GP6
Cause: The lower cleaner head open limit (X05A) and close limit (X05B) sensors have either both turned
on or both turned off at the same time.
Remedy: Check the lower cleaner head open limit and close limit sensors, and adjust them as necessary.
------------------------------
Code: 1205600D
Display: "Sensor logical alarm: cleaner notch" (GP6)
Used by: GP6
Cause: The cleaner notch sensors (X05D and X05E) sensors have either both turned on or both turned
off at the same time.
Remedy: If the machine supports a double-side cleaner, check and adjust the sensors for the notch that
connects the cleaner to the S-axis. If the machine uses a single-side cleaner, check and adjustthe sensors
for the notch that connects the cleaner to the cleaner shift.
------------------------------
Code: 1205600E
第 575 页
Display: "Sensor logical alarm: cleaner shift" (GP6)
Used by: GP6
Cause: The cleaner shift forward end (X07C) and retract end (X07D) sensors have either both turned on
or both turned off at the same time.
Remedy: Check the cleaner shift forward end and retract end sensors, and adjust them as necessary.
------------------------------
Code: 1205600F
Display: "M/C err Sensor SQG Holder" (GP6 w/single squeegee), "M/C err Sensor
SQG F" (front squeegee on double-squeegee GP6), "M/C err Sensor SQG R"
(rear squeegee on double-squeegee GP6)
Used by: GP6
Cause: The squeegee holder upper limit and lower limit check sensors (X070 and X071 for either a single
squeegee or squeegee F, and X078 and X079 for squeegee R) have either both turned on or both turned off
at the same time.
Remedy: Check the squeegee holder upper limit and lower limit check sensors, and adjust them as
necessary.
------------------------------
Code: 12056010
Display: "M/C err Sensor Top Cleaner Connected"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056011
Display: "Sensor Logic Error Conveyor Width Clutch"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056012
Display: "Sensor Logic Error Push Plate"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056013
Display: "M/C err Sensor Holder **(UPorDOWN)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056014
Display: "Sensor Logic Error SQG Open/Close"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
第 576 页
------------------------------
Code: 12056015
Display: "Sensor Logic Error Solder Pusher"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056016
Display: "M/C err Sensor Cleaner Released"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056017
Display: "M/C err Sensor Clnr Head **** (Open or Close)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056018
Display: "Sensor Logic Error Replenish *** Wrn (BTM or TOP)"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056019
Display: "Sensor Logic Error Screen Clamp Top"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601A
Display: "Sensor Logic Error Solder Supply UP/DN"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601B
Display: "Sensor Logic Error Mask Supprt"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601C