FUJI错误代码查询.pdf - 第833页
"?" indicates the module number (QP2). "****" indicates the error code. Remedy: Check connection between the LLL board and the sensor. Check the cables.(encoder cable etc.) ---------------------------…
Used by: QP242,NP2,QP3
Cause: Failed to pick-up an empty tray during its removal.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the remover has sufficient vacuum pressure. Also, ensure an error has not occurred
at the empty tray pick-up confirmation sensor (TRAY PICKUP CHK).
------------------------------
Code: 1207E?63
Display: "ICM(PMC?,SCU?) Error Code:********"
"No clip tray"
Used by: QP203
Cause: The machine has run out of spring clip trays.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Supply spring clip trays.
------------------------------
Code: 1207E?64
Display: "ICM(PMC?,SCU?) Error Code:********"
"No spreader/clip tray"
Used by: QP203
Cause: The machine has run out of heat spreader and spring clip trays.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Supply heat spreader and spring clip trays.
------------------------------
Code: 1207E?66
Display: "ICM(PMC?,SCU?) Error Code:********"
"Heat spreader parts out"
Used by: QP203
Cause: Heat spreader parts have run out.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Re-supply spreader parts.
------------------------------
Code: 1207E?67
Display: "SCU? (PMC?, ICM) Error Code:********"
"Dip flux unit alarm"
Used by: QP242
Cause: An alarm occurred during the operation of the dip flux unit.
Remedy: Check that the air supply is connected properly, or that the sequencer is operating correctly.
------------------------------
Code: 1207E?68
Display: "SCU? (PMC?, ICM) Error Code:********"
"Dip flux unit time out"
Used by: QP242
Cause: The dip flux unit did not complete its operation within the specified time limit."
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check that the power supply is connected properly.
------------------------------
Code: 1207E?69
Display: "SCU? (PMC?, ICM) Error Code:********"
"Failed to rec X calib data"
Used by: QP242
Cause: Failed to receive X-axis calibration data from the LLL.
第 832 页
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check connection between the LLL board and the sensor.
Check the cables.(encoder cable etc.)
------------------------------
Code: 1207E?6A
Display: "SCU? (PMC?, ICM) Error Code:********"
"Failed to rec Y calib data"
Used by: QP242
Cause: Failed to receive Y-axis calibration data from the LLL.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check connection between the LLL board and the sensor.
Check the cables.(encoder cable etc.)
------------------------------
Code: 1207E?6B
Display: "SCU? (PMC?, ICM) Error Code:********"
"Spring clip dislodged"
Used by: QP203
Cause: The clip was partially or completely dislodged from the FOL carrier. The question marks (?)
represent the module number. The asterisks (***) represent the error code.
Remedy: Check that the clips are being correctly placed, and that they are securely in position on the
carrier. Care should be taken as the clips may become dislodged.
------------------------------
Code: 1207E?6C
Display: "SCU? (PMC?, ICM) Error Code:********"
"Nozzle station not lowered"
Used by: QP242
Cause: The nozzle station is not at its lowered position.
Remedy: Use commands at the machine to lower the nozzle station and restart operation. If the nozzle
station is at its lowered position when this message appears, check the lower limit sensor.
------------------------------
Code: 1207E?6D
Display: "SCU? (PMC?, ICM) Error Code:********"
"Remover-lifter not lowered"(QP2)
Remover origin position error.(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The remover-lifter is not at its lowered position.(QP2)
The tray remover is not attached to the lifter.(NP2,QP3)
Remedy: Use commands at the machine to lower the remover-lifter and restart operation. If the remover-
lifter is at its lowered position when this message appears, check the lower limit sensor.(QP2)
Return tray remover to the lifter (auto recovery failed).If the remover is correctly attached to the
lifter, check the action of the tray remover detection sensor.(NP2,QP3)
------------------------------
Code: 1207E?6E
Display: "SCU? (PMC?, ICM) Error Code:********"
"Placed parts dislodged"
Used by: QP201
Cause: The parts was partially or completely dislodged from the FOL carrier. The question marks (?)
represent the module number. The asterisks (***) represent the error code.
Remedy: Check that the parts are being correctly placed, and that they are securely in position on the
第 833 页
carrier. Care should be taken as the parts may become dislodged.
------------------------------
Code: 1207E?6F
Display: "SCU? (PMC?, ICM) Error Code:********"
"Pocket unclamping error"
Used by: QP201
Cause: The FOL carrier pocket clamps were not released within the required time.(The question marks
represent the module number, and the asterisks represent the error code.)
Remedy: Check the action of the pocket clamps.
------------------------------
Code: 1207E?70
Display: "SCU? (PMC?, ICM) Error Code:********"
"Packages on carrier"
Used by: QP201
Cause: Packages ware detected on the carrier during conveyance.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Check whether there are packages on the carrier.
------------------------------
Code: 1207E?71
Display: "SCU? (PMC?, ICM) Error Code:********"
"Part supply direction error"
Used by: QP203
Cause: The supply direction of the heat spreader parts on the coin stack feeder may be incorrect.(The
question marks represent the module number, and the asterisks represent the error code.)
Remedy: Check the direction of the spreader parts on the coin stack feeder.
------------------------------
Code: 1207E?72
Display: "SCU? (PMC?, ICM) Error Code:********"
"Feeder interference area"
Used by: QP203
Cause: The head is inside the coin stack feeder interference area.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Move the head outside the coin stack feeder interference area.
------------------------------
Code: 1207F?00
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Controller Error"
Used by: QP242
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
Code: 1207F?01
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. This error may also be caused by breaks in cables, or by
第 834 页