FUJI错误代码查询.pdf - 第156页
Remedy: Enter the correct Proper value and re-transmit the Proper data. ------------------------------ Code: 11022619 Display: Used by: IP2 Cause: Error conveyor is set at 0 (IP2). Remedy: Enter the correct Proper value …
Display:
Used by: IP2
Cause: XC 4, YC 4 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022611
Display:
Used by: IP2
Cause: Camera X1, Y1 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022612
Display:
Used by: IP2
Cause: Camera X2, Y2 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022613
Display:
Used by: IP2
Cause: Camera X3, Y3 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022614
Display:
Used by: IP2
Cause: Camera X4, Y4 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022615
Display:
Used by: IP2
Cause: X dot 1, Y dot 1 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022616
Display:
Used by: IP2
Cause: X dot 2, Y dot 2 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022617
Display:
Used by: IP2
Cause: X dot H, Y dot H is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022618
Display:
Used by: IP2
Cause: X act origin is set at 0 (IP2).
第 155 页
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022619
Display:
Used by: IP2
Cause: Error conveyor is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261A
Display:
Used by: IP2
Cause: Error Box X, Y is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261B
Display:
Used by: IP2
Cause: Y loading pos. is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261C
Display:
Used by: IP2
Cause: The Proper data item Acceleration time X is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261D
Display:
Used by: IP2
Cause: The Proper data item Acceleration time Y is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261E
Display:
Used by: IP2
Cause: The Proper data item Acceleration time Z is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261F
Display:
Used by: IP2
Cause: The Proper data item Acceleration time Q is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022620
Display:
Used by: IP2
Cause: The Proper data item Reducing time X is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022621
第 156 页
Display:
Used by: IP2
Cause: The Proper data item Reducing time Y is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022622
Display:
Used by: IP2
Cause: The Proper data item Reducing time Z is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022623
Display:
Used by: IP2
Cause: The Proper data item Reducing time Q is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022624
Display: ATC POSITION ERROR
Used by: IP2
Cause: The Proper value 64.X_atc_origin_2 is smaller than 35.X_atc_origin (setting was not made).
Remedy: Make the Proper measurement and enter it. This displays only on the IP1 with shift type
nozzles.
------------------------------
Code: 11022630
Display:
Used by: IP2
Cause: Proper data's X_max is smaller than the values X1_ESC and X2_ESC.
Remedy: Input the correct Proper values.
------------------------------
Code: 11022631
Display:
Used by: IP2
Cause: Proper data's X_max is smaller than the values X1_wait and X2_wait.
Remedy: Input the correct Proper values.
------------------------------
Code: 11022632
Display:
Used by: IP2
Cause: Proper data's X_max is smaller than the values Nozzle_check_pos.1 and Nozzle_check_pos.2.
Remedy: Input the correct Proper values.
------------------------------
Code: 11022633
Display: None
Used by: IP2,IP3
Cause: When using the placing pressure control function, the 6 channel communication board port
number is the same as another port number. Alternatively, the port number (from 11 to 30) is out of
range (FIP3).
Remedy: Change the communication port number (Pressure control port no.) in Proper data (FIP3).
------------------------------
Code: 11022634
第 157 页