FUJI错误代码查询.pdf - 第727页
"VP Camera Type Mismatch" (QP2) Used by: QP242,QP201,QP202,QP203 Cause: An incorrect camera type has been specified by a vision processing request. (value replacing "?" is module number; error code ap…
Cause: Vision processing system error. (This is an internal processing code.)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy:
------------------------------
Code: 12070?43
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts Supply NG" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has run out components, or there is a problem affecting the supply of components.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?44
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Specified Axis Exists" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Software internal processing has determined that the specified axis does not exist.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?45
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Can't Move To Nozzle Sta" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The head can't move directly to the nozzle change station.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?46
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Program Size Changed" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The program size has been changed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Production cannot be continued if the current production program is changed to a program with
more/less sequences, or device changes. Return to the original program, or clear the current production
program memory by selecting [PM]-[Program]-[Delete]. In this case, modules where the program memory
has been cleared start production from the beginning.
------------------------------
Code: 12070?47
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 726 页
"VP Camera Type Mismatch" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: An incorrect camera type has been specified by a vision processing request.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the "Camera Type" parameter in the Proper data for the module that caused the error.
------------------------------
Code: 12070?48
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mark Seq Request LS Camera" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine has received a vision processing request that requires a light sensor camera to
process a mark sequence.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?4A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Executing Prog Delete Req" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A deletion request has been issued for the program being executed.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?4B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Data Rcvd Prior DC Data Req" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Data was transmitted before a device check data request command was received.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?4C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Connect Request Not Permit" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An attempt has been made to connect a sub-terminal when sub-terminal connection is not
permitted, as is the case during automatic operation.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Return the operation screen to original command status, then connect the sub-terminal.
------------------------------
第 727 页
Code: 12070?4D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Parameter" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Valid parameters have not been transmitted to the module that caused the error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Retransmit the Proper data from the host computer.
------------------------------
Code: 12070?4E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(Parameter Trans)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received during parameter transmission.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?4F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unexecutable(prog Trans'g)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received during program transmission.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?51
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command Unaccepted(VPing)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received during vision processing.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?52
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 728 页