FUJI错误代码查询.pdf - 第2248页
Display: Presently not used. Used by: Cause: Remedy: ------------------------------ Code: 51??4002 Display: Presently not used. Used by: Cause: Remedy: ------------------------------ Code: 51??4003 Display: The cell stat…
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data.
------------------------------
Code: 51??2100
Display: No "UNIT", "STATUS" or "UNIT", "STATUS" is not at the correct position.
Used by:
Cause: "UNIT", "STATUS" was not found in the specified status data or "UNIT", "STATUS" does not follow
the correct unit.
Remedy: Check the "UNIT", "STATUS" setting in status data. Alternatively, check the setting of the "UNIT"
line prior to "UNIT", "STATUS".
------------------------------
Code: 51??2101
Display: No "UNIT", "STATUS" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS" - "BLOCK", "HEADER-".
------------------------------
Code: 51??2102
Display: No "UNIT", "STATUS" - "BLOCK", "STATDT-".
Used by:
Cause: "BLOCK", "STATDT-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS" - "BLOCK", "STATDT-".
------------------------------
Code: 51??2105
Display: No "UNIT", "STATUS" - "BLOCK", "IMAGE-".
Used by:
Cause: "BLOCK", "IMAGE-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS"-"BLOCK", "IMAGE-". Furthermore, check
"FILESTRUCT" in "UNIT", "STRUCT".
------------------------------
Code: 51??2106
Display: No vQN line in "UNIT", "STATUS" - "BLOCK", "IMAGE-".
Used by:
Cause: The vQN line in "UNIT", "STATUS" - "BLOCK", "IMAGE-" in the specified transmission image type
status data was not found.
Remedy: Check the content of "UNIT", "STATUS" - "BLOCK", "IMAGE-" in the production program.
------------------------------
Code: 51??2111
Display: "UNIT", "STATUS" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "STATUS" in the specified status data was read and a format error was detected in
"BLOCK", "HEADER-".
Remedy: Check the setting for "UNIT", "STATUS" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 51??2112
Display: "UNIT", "STATUS" - "BLOCK", "STATDT-" format error.
Used by:
Cause: "UNIT", "STATUS" in the specified status data was read and a format error was detected in
"BLOCK", "STATDT-".
Remedy: Check the setting for "UNIT", "STATUS" - "BLOCK", "STATDT-" in status data.
------------------------------
Code: 51??4001
第 2247 页
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------
Code: 51??4002
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------
Code: 51??4003
Display: The cell status is underfined.
Used by:
Cause: A board type report was confirmed for a machine with an underfined cell status.
Remedy: Request the cell status.
------------------------------
Code: 51??4004
Display: Named pipe could not be created.
Used by:
Cause: The named pipe used to read the CCPSS process could not be created or opened.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4005
Display: Remote command named pipe could not be opened.
Used by:
Cause: The named pipe used to read the remote command could not be opened.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4006
Display: No reply from command server to the transmit OK request.
Used by:
Cause: An attempt was made to receive a reply from the command server to the transmit OK request but
a read error occurred in the named pipe. This error occurs if there is a named pipe read error or an
incorrect format for the transmit OK request, and may be caused by the C/C not operating properly.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4007
Display: Remote command did not start.
Used by:
Cause: An attempt was made to receive a startup report from the remote command but a read error
occurred in the named pipe. This error occurs if there is a named pipe read error and may be caused by
the C/C not operating properly.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4008
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------
第 2248 页
Code: 51??4009
Display: Command execution status could not be registered.
Used by:
Cause: The command execution status for the client process could not be registered. This error occurs if
either the named pipe for the client process cannot be opened or an error occurs when writing to the
named pipe, and may be caused by the C/C not operating properly.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4010
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------
Code: 51??4011
Display: Named pipe could not be read.
Used by:
Cause: For some reason the named pipe could not be read.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4012
Display: SECS/GEM could not be initialized.
Used by:
Cause: For some reason SECS/GEM could not be initialized.
Remedy: Check that SECS/GEM is operating properly. Otherwise cease using SECS/GEM.
------------------------------
Code: 51??4013
Display: Command could not be started.
Used by:
Cause: The slave process could not be started. The cause may be one of the following: There is no
command file, the command file is damaged, the directory storing the command has no path setting.
Remedy: Check the path setting or reinstall ProduSS.
------------------------------
Code: 51??4014
Display: Line descriptor data cannot be acquired.
Used by:
Cause: The line descriptor information created in the memory cannot be acquired. This error may be
caused by the C/C not operating properly.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4015
Display: Insufficient memory.
Used by:
Cause: The required memory space cannot be secured due to insufficient memory.
Remedy: Install more memory or halt the execution of processes which consume a lot of memory or
remove unnecessary modules from the memory.
------------------------------
Code: 51??4016
Display: Cannot connect.
Used by:
Cause: For some reason a connection cannot be made with ProduSS.
第 2249 页