Code: 1D114041
Display:
Used by:
Cause: The image is not set (the nozzle is dirty or there is foreign matter on the parts), the part is mis-
shaped (the edges are uneven), and there is a large discrepancy between the part and the values set in
Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D114042
Display:
Used by:
Cause: The Part data body size is too large compared to the part.
Remedy: Check Part data. Alternately, check whether the nozzle is dirty, there is foreign matter on the
parts, or the wrong parts are being used.
------------------------------
Code: 1D114043
Display:
Used by:
Cause: The Part data body size is too small compared to the part.
Remedy: Check Part data. Alternately, check whether the nozzle is dirty, there is foreign matter on the
parts, or the wrong parts are being used.
------------------------------
Code: 1D114044
Display:
Used by:
Cause: The size of the part differs from the value in Part data by more than +-10%.
Remedy: Check Part data. Alternately, check whether the nozzle is dirty, there is foreign matter on the
parts, or the wrong parts are being used.
------------------------------
Code: 1D114045
Display:
Used by:
Cause: The part is tilted more than +-15 deg. or the part length is wrong.
Remedy: Check Part data. Alternately, check whether the nozzle is dirty, there is foreign matter on the
parts, or the wrong parts are being used.
------------------------------
Code: 1D114046
Display:
Used by:
Cause: The image is not set (the nozzle is dirty or there is foreign matter on the parts), the part is mis-
shaped (the edges are uneven), and there is a large discrepancy between the part and the values set in
Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D114047
Display:
Used by:
Cause: The image is not set (the nozzle is dirty or there is foreign matter on the parts), the part is mis-
第 1415 页
shaped (the edges are uneven), and there is a large discrepancy between the part and the values set in
Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D114048
Display:
Used by:
Cause: The lead could not be found.
Remedy: Check the part shape and Part data.
------------------------------
Code: 1D114049
Display:
Used by:
Cause: The lead pitch is outside the accepted range.
Remedy: Check the shape of the part.
------------------------------
Code: 1D11404A
Display:
Used by:
Cause: The part could not be found. The part shape could not be detected.
Remedy: Check Part data and check that the part is being picked correctly. Check that vision processing
is taking the image correctly.
------------------------------
Code: 1D11404B
Display:
Used by:
Cause: The lead could not be found.
Remedy: Check that the image produces the correct lead length and width.
------------------------------
Code: 1D11404C
Display:
Used by:
Cause: The tilt of the part exceeds 15 deg.. The four areas are not uniform in tilt.
Remedy: Check that the part is being picked correctly, and check the part shape.
------------------------------
Code: 1D118002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D118100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D118110
Display:
第 1416 页
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D118111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D118112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D118113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D118114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D118115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D118120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D118121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D118122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.