------------------------------ Code: 1D0F8002 Display: Used by: Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not detect any part. Remedy: Re-supply parts. If parts …
Used by:
Cause: The part boundary could not be found.
Remedy: Check the part shape and check that the vision processing system is taking the image correctly.
------------------------------
Code: 1D0F4016
Display:
Used by:
Cause: The lead could not be found.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D0F4019
Display:
Used by:
Cause: The lead could not be found.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D0F401B
Display:
Used by:
Cause: The lead could not be found.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D0F401C
Display:
Used by:
Cause: The lead could not be found.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D0F401D
Display:
Used by:
Cause: The part boundary could not be found.
Remedy: Check the part shape and check that the vision processing system is taking the image correctly.
------------------------------
Code: 1D0F401F
Display:
Used by:
Cause: There are too many leads.
Remedy: Check the part shape, and check that the vision processing system is taking the image correctly.
------------------------------
Code: 1D0F4020
Display:
Used by:
Cause: The part boundary could not be found.
Remedy: Check the part shape and check that the vision processing system is taking the image correctly.
------------------------------
Code: 1D0F4021
Display:
Used by:
Cause: The part boundary could not be found.
Remedy: Check the part shape and check that the vision processing system is taking the image correctly.
第 1396 页
------------------------------
Code: 1D0F8002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D0F8100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D0F8110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D0F8111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D0F8112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D0F8113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D0F8114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D0F8115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
第 1397 页
Code: 1D0F8120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D0F8121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D0F8122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D0F8123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D0F82??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0F83??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0F84??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0F85??
Display:
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.