FUJI错误代码查询.pdf - 第45页
Cause: The device number and holder number contradict each other (sequences 1751~1875). Remedy: Check sequences 1751~1875. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3) each have device numbers from wh…
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 11011639
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 1126~1250).
Remedy: Check sequences 1126~1250. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 1101163A
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 1251~1375).
Remedy: Check sequences 1251~1375. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 1101163B
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 1376~1500).
Remedy: Check sequences 1376~1500. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 1101163C
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 1501~1625).
Remedy: Check sequences 1501~1625. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 1101163D
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 1626~1750).
Remedy: Check sequences 1626~1750. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 1101163E
Display:
Used by: IP2
第 44 页
Cause: The device number and holder number contradict each other
(sequences 1751~1875).
Remedy: Check sequences 1751~1875. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 1101163F
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 1876~2000).
Remedy: Check sequences 1876~2000. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 11011640
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0001~0125).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0001~0125.
Input the object device numbers for those sequences.
------------------------------
Code: 11011641
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0126~0250).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0126~0250.
Input the object device numbers for those sequences.
------------------------------
Code: 11011642
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0251~0375).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0251~0375.
Input the object device numbers for those sequences.
------------------------------
Code: 11011643
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0376~0500).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0376~0500.
Input the object device numbers for those sequences.
------------------------------
Code: 11011644
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0501~0625).
第 45 页
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0501~0625.
Input the object device numbers for those sequences.
------------------------------
Code: 11011645
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0626~0750).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0626~0750.
Input the object device numbers for those sequences.
------------------------------
Code: 11011646
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0751~0875).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0751~0875.
Input the object device numbers for those sequences.
------------------------------
Code: 11011647
Display:
Used by: IP2
Cause: Feeder type check error (sequences 0876~1000).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0876~1000.
Input the object device numbers for those sequences.
------------------------------
Code: 11011648
Display:
Used by: IP2
Cause: Feeder type check eeror (sequences 1001~1125).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
1001~1125.
Input the object device numbers for those sequences.
------------------------------
Code: 11011649
Display:
Used by: IP2
Cause: Feeder type check error (sequences 1126~1250).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
1126~1250.
Input the object device numbers for those sequences.
------------------------------
Code: 1101164A
Display:
Used by: IP2
Cause: Feeder type check error (sequences 1251~1375).
Remedy: 0 is input in package_type (MCS/2) or device_type (MCS/1) in the devices in use at sequences
0001~0125.
Input the object device numbers for those sequences.
第 46 页