------------------------------ Code: 21007647 Display: Cam_table file seek error Used by: Cause: The seek function did not work on the system file. Remedy: Re-install the Automatic Programming software. -----------------…

100%1 / 5282
Cause: The input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 2100763F
Display: Output program file name is too long
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007640
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 21007641
Display: Base program file name is too long
Used by:
Cause: The base program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007642
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 21007643
Display: Make not mount sequence
Used by:
Cause: The Queue data (used in the strategy section of the system file) could not be created.
Remedy: Reboot MCS. If the error recurs, replace the MPU (memory) board.
------------------------------
Code: 21007644
Display: No entry Machine name
Used by:
Cause: The machine entered in the "Type" heading in "Sep_data" could not be found.
Remedy: Input the correct machine name under the "Type" (do not forget to also input "Time" and
"Device_Name") heading.
------------------------------
Code: 21007645
Display: Cam_table file open error
Used by:
Cause: The system file could not be opened.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007646
Display: Cam_table file read error
Used by:
Cause: The system file could not be read.
Remedy: Re-install the Automatic Programming software.
第 1953 页
------------------------------
Code: 21007647
Display: Cam_table file seek error
Used by:
Cause: The seek function did not work on the system file.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007648
Display: Cam_table file path read error
Used by:
Cause: The input path could not be specified.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 21007649
Display: Not get cycle time
Used by:
Cause: Management time could not be calculated.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100764A
Display: Illegal format at Cam_table
Used by:
Cause: The cam table is not formatted correctly.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100764B
Display: Pairing pattern file open error
Used by:
Cause: The system file could not be opened.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100764C
Display: Pairing pattern file read error
Used by:
Cause: The system file could not be read.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100764D
Display: Pairing pattern file file value different
Used by:
Cause: The contents of the system file are not normal.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100764E
Display: Not get queue position
Used by:
Cause: Memory could not be processed.
Remedy: Re-boot MCS.
------------------------------
Code: 2100764F
Display: Sequence data co-ordinates over range
第 1954 页
Used by:
Cause: The coordinates in the sequence data are outside the board range.
Remedy: Check that the correct values are input in XA, YA, Pcb_x and Pcb_y in the production program.
Check that the correct values are input in Pcb_org in the environment file. Pcb_org=x,y, board orientation
and change flag should be checked. The check flag could be either 0 or 1.
------------------------------
Code: 21007650
Display:
Used by:
Cause: The environment file could not be opened.
Remedy: Re-install the software.
------------------------------
Code: 21007651
Display:
Used by:
Cause: The environment file could not be read.
Remedy: Re-install the software.
------------------------------
Code: 21007652
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 21007653
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007654
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007700
Display: Illegal parameter option
Used by:
Cause: The start-up parameter is illegal.
Remedy: When doing direct start up, check and correct the input options.
------------------------------
Code: 21007701
Display: Message file read error
Used by:
Cause: Unable to read the message file.
Remedy: Re-install the software.
------------------------------
Code: 21007702