Used by: Cause: Either no data was entered into the paste buffer or the paste command tried put the data into a different field. Remedy: Data can only be pasted into the same field. ------------------------------ Code: 2…

100%1 / 5282
Used by:
Cause: The device size of the Device data is too small or too large for the field.
Remedy: The data field cannot be edited at this point, so make sure it is correct beforehand.
------------------------------
Code: 21005604
Display: Data type cannot accept characters.
Used by:
Cause: This data type only accepts numerical input.
Remedy: Input numerical data.
------------------------------
Code: 21005605
Display: can't execute Srch/rpl command
Used by:
Cause: This is a multiple-heading field. A batch input was attempted for a single data field.
Remedy: Select more than one data field with the cursor. Batch input can only be performed in multiple-
heading fields.
------------------------------
Code: 21005606
Display: Search data or replace data not specified.
Used by:
Cause: The address of the data has not been set.
Remedy: Specify the address of the data and re-execute.
------------------------------
Code: 21005700
Display: Copy line overflow
Used by:
Cause: In the editor there is a buffer, allowing the maximum number of lines to double. This buffer has
overflowed.
Remedy: Eliminate all unnecessary data.
------------------------------
Code: 21005701
Display: Paste buffer overflow - clear buffer? [y/n]
Used by:
Cause: Copy command overflow mode was executed over 100 times.
Remedy: Clear either the paste buffer or clear buffer or both.
------------------------------
Code: 21005702
Display: Single entry data. Function key not valid
Used by:
Cause: The function key used cannot handle multiple-entry data. The copy, delete and other such keys
can only handle single entry data.
Remedy: Input single entry data.
------------------------------
Code: 21005703
Display: Data field over
Used by:
Cause: The specified address is out of the data field.
Remedy: Check the input data.
------------------------------
Code: 21005704
Display: Data field no match
第 1885 页
Used by:
Cause: Either no data was entered into the paste buffer or the paste command tried put the data into a
different field.
Remedy: Data can only be pasted into the same field.
------------------------------
Code: 21005705
Display: Copy line is record field over
Used by:
Cause: The data exceeded the range of the field during copying. (Data is recorded up to the range of the
field.)
Remedy: Sufficient space is allowed for data so this problem should seldom occur. Field size cannot be
changed at this point, so make sure it is correct beforehand.
------------------------------
Code: 21005706
Display: Data entry error
Used by:
Cause: The data entry was out of range.
Remedy: Check the input data.
------------------------------
Code: 21005801
Display: Digitizer not found
Used by:
Cause: The digitizer is not registered in the line descriptor.
Remedy: Register the digitizer (Mc_type=18) in the editor (line descriptor) and re-boot the system. Refer to
the operation manual, Part 2, Sections 1,2 and 3 for details.
------------------------------
Code: 21005802
Display: Digitizer time out error
Used by:
Cause: Nothing was received from the digitizer within the specified time limit.
Remedy: Check that the cable and connector is properly connected. Perform the self-test on port RS
232C.
------------------------------
Code: 21005803
Display: Digitizer data error
Used by:
Cause: The data from the digitizer is out of range.
Remedy: Check the range of entry.
------------------------------
Code: 21005811
Display: file name error
Used by:
Cause: The filename is longer than 19 characters. This number includes appendages such as ".exp."
Remedy: Shorten it.
------------------------------
Code: 21005900
Display: Now editting data is not Programe data
Used by:
Cause: The cut command was used on data which was not in the production program or the source
program.
Remedy: Do not use the cut command on data which is not in the production program or source program.
第 1886 页
------------------------------
Code: 21005901
Display: Now edttting data is not Squence data
Used by:
Cause: The cut command was used on data which was not sequence data.
Remedy: Only use the cut command on sequence data.
------------------------------
Code: 21005902
Display: Cut number syntax error
Used by:
Cause: In the cut command "0" or "1" was used. The cut command must use the number "2" or greater.
Remedy: The cut command erases all the sequence data lines greater than the number input. Input "2"
or greater. In sequence data, at least one line is necessary.
------------------------------
Code: 21005903
Display: Input sequence NO. not found.
Used by:
Cause: The sequence number does not exist.
Remedy: Check the sequence data and re-execute the sequence.
------------------------------
Code: 21005950
Display: Edit command not execute
Used by:
Cause: The sub-editor could not handle the overflow.
Remedy: At a terminal there can be up to 2 editors. If a new editor has been opened, try again after
closing the sub-editor.
------------------------------
Code: 21006000
Display: Illegal parameter
Used by:
Cause: The parameter is illegal.
Remedy: Check the parameter.
------------------------------
Code: 21006001
Display: message file read error
Used by:
Cause: The message file could not be read.
Remedy: Re-install the separator software.
------------------------------
Code: 21006002
Display: console pipe open error
Used by:
Cause: Unable to open the console pipe.
Remedy: Re-boot MCS.
------------------------------
Code: 21006003
Display: CRT semaphore link error
Used by:
Cause: The CRT semaphore ID could not be obtained.
Remedy: Re-boot MCS.
------------------------------