FUJI错误代码查询.pdf - 第281页

Used by: QP242,QP201,QP202,QP203 Cause: The y direction pitch data for the parts arranged in the tray is not specified. Remedy: Specify correct data for 15. (Tray:) Component_pitch_y in Part data's Package_and_appea…

100%1 / 5282
Used by: QP242
The first "?" is the station number. The last two "??" are the device number in hexadecimal code. For
inputs of 256 and above, 256 is subtracted.
Cause: Although the continuous pass flux (or stroke flux) method is set in the device data, the
application head speed has not been set.
The item "Apply Head Speed" in part data has not been set.
Remedy: Specify an appropriate value and retransmit the production program.
------------------------------
Code: 11D30???
Display: 11D30???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by:
Cause: The number of feeding times (Feeding_tim_CP4,5) specified in part data is inappropriate.
Remedy: Change the number of feeding times for the relevant feeder (device) and then re-transmit the
program.
------------------------------
Code: 11D31???
Display: 11D31???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by:
Cause: The package type which is specified in part data is incorrect.
Remedy: Specify correct data for 4. Package_type in Part data's Package_and_appearance data.
------------------------------
Code: 11D40???
Display: 11D40???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by:
Cause: The tray type setting is incorrect.
Remedy: Specify correct data for 11. (Tray:) Tray_type in Part data's Package_and_appearance_data.
------------------------------
Code: 11D41???
Display: 11D41???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The x direction pitch data for the parts arranged in the tray is not specified.
Remedy: Specify correct data for 14. (Tray:) Component_pitch_x in Part data's
Package_and_appearance_data.
------------------------------
Code: 11D42???
Display: 11D42???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
第 280 页
Used by: QP242,QP201,QP202,QP203
Cause: The y direction pitch data for the parts arranged in the tray is not specified.
Remedy: Specify correct data for 15. (Tray:) Component_pitch_y in Part data's
Package_and_appearance_data.
------------------------------
Code: 11D43???
Display: 11D43???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The number of parts arranged in the x direction in the tray is not specified.
Remedy: Specify correct data for 16. (Tray:) Cavities_x in Part data's Package_and_appearance_data.
------------------------------
Code: 11D44???
Display: 11D44???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The number of parts arranged in the y direction in the tray is not specified.
Remedy: Specify correct data for 17. (Tray:) Cavities_y in Part data's Package_and_appearance_data.
------------------------------
Code: 11D45???
Display: 11D45???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The x coordinate of the point at which the tray is picked up in order to be discarded is not
specified.
Remedy: Specify correct data for 21. (Tray:) Tray_pickup_pnt_x in Part data's
Package_and_appearance_data.
------------------------------
Code: 11D46???
Display: 11D46???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The y coordinate of the point at which the tray is picked up in order to be discarded is not
specified.
Remedy: Specify correct data for 23. (Tray:) Tray_pickup_pnt_y in Part data's
Package_and_appearance_data.
------------------------------
Code: 11D47???
Display: Same as code The value replacing the first "?" is the station number; the values for the remaining
"??" indicate a device number within that station. These numbers appear as hexadecimal values. When a
device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the tray size X dimension.
第 281 页
Remedy: Set the correct value for the "Package Data Dimension_x (F4G)" parameter in the Part data.
------------------------------
Code: 11D48???
Display: Same as code The value replacing the first "?" is the station number; the values for the remaining
"??" indicate a device number within that station. These numbers appear as hexadecimal values. When a
device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the tray size Y dimension.
Remedy: Set the correct value for the "Package Data Dimension_y (F4G)" parameter in the Part data.
------------------------------
Code: 11D49???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by:
Cause: No "Tray_infomation" data has been transmitted in the Part data (for the FIP3).
Remedy: "Tray_infomation" data is necessary because a value of 6 or 7 has been set for the
"11.(Tray:)Tray_type (MCS/2)" parameter under "Package_and_appearance_data" in the Part data. Use a
host computer corresponding to Tray_type 6 or 7.
------------------------------
Code: 11D4A???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242
Cause: The tray part's specified pick-up position falls outside the tray dimensions.
Remedy: Retransmit the production program to the machine after correcting the following part data items:
"Tray First Pickup Point X,Y"
"Tray Cavity Pitch X,Y"
"Tray Cavity Quantity Side X,Y"
"Tray Dimension Size X,Y"
------------------------------
Code: 11D4B???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242
Cause: The empty tray's specified pick-up position falls outside the tray dimensions.
Remedy: Retransmit the production program to the machine after correcting the following part data items:
"Tray Eject Pickup Point X,Y"
"Tray Dimension Size X,Y"
------------------------------
Code: 11D4C???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242
Cause: Parts with an upper surface of more than 7 mm above the tray surface cannot be handled at
modules where all four of the following conditions apply.
ˇ Parts are being supplied from the front of the machine.
ˇ Camera type 7 is used.
第 282 页