Cause: X data is out of range (sequences 0126~0250). Remedy: Check the X item in sequences 0126~0250. ------------------------------ Code: 11011002 Display: Used by: CP3,CP4-1,CP4-2,CP5,IP2 Cause: X data is out of range …
Code: 11010405
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Pcb_x" setting is incorrect.
Remedy: After checking "Pcb_x" in MCS, transmit the program. When the next production stage is the
reflow oven, the MBID range is 80.00~508.00.
In other words, when Machine_type = 7 and Machine_control_mode = 5, then Pcb_x = 80.00~508.00.
Otherwise, there are no special settings.
------------------------------
Code: 11010406
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Pcb_y" setting is incorrect.
Remedy: After checking "Pcb_y" in MCS, transmit the program. When using a board stacker, and is
communicating with the next production stage via an RS-232C, the MBID range is 50.00~457.00. That is,
when Machine_type = 5 or Machine_type = 7, and Machine_control_mode = 2~5, then Pcb_y =
50.00~457.00. Otherwise, there are no special settings.
------------------------------
Code: 11010407
Display: Same as code
Used by: GP551,GP6
Cause: The value specified at the item "Solder_supply_stroke" in the production program is outside the
acceptable range. The following input ranges are for the GP-641E series machines:
Greatest value:For machines with single squeegees.
New solder cutter mode:350 [mm]
Existing solder cutter mode:420 [mm]
For machines with double squeegees:460 [mm]
Minimum value:The values vary depending upon the solder supply speed.
Supply speed [mm/sec]Minimum value [mm]
40 -->60
80 -->80
120 -->120
160 -->200
200 -->240
Remedy: Input a value for the item "Solder_supply_stroke" that is within the permissible range.
------------------------------
Code: 11010408
Display: The position of global skip mark is incorrect.
Used by: IP3,QP242,QP201,QP202,QP203
Cause: The global skip mark has been set after a block skip mark set at block 1.
Remedy: Set the global skip mark in advance of the block skip mark.
------------------------------
Code: 11011000
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0001~0125).
Remedy: Check the X item in sequences 0001~0125.
------------------------------
Code: 11011001
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
第 11 页
Cause: X data is out of range (sequences 0126~0250).
Remedy: Check the X item in sequences 0126~0250.
------------------------------
Code: 11011002
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0251~0375).
Remedy: Check the X item in sequences 0251~0375.
------------------------------
Code: 11011003
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0376~0500).
Remedy: Check the X item in sequences 0376~0500.
------------------------------
Code: 11011004
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0626~0750).
Remedy: Check the X item in sequences 0626~0750.
------------------------------
Code: 11011005
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0626~0750).
Remedy: Check the X item in sequences 0626~0750.
------------------------------
Code: 11011006
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0751~0875).
Remedy: Check the X item in sequences 0751~0875.
------------------------------
Code: 11011007
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0876~1000).
Remedy: Check the X item in sequences 0876~1000.
------------------------------
Code: 11011008
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1001~1125).
Remedy: Check the X item in sequences 1001~1125.
------------------------------
Code: 11011009
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1126~1250).
Remedy: Check the X item in sequences 1126~1250.
------------------------------
第 12 页
Code: 1101100A
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1251~1375).
Remedy: Check the X item in sequences 1251~1375.
------------------------------
Code: 1101100B
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1376~1500).
Remedy: Check the X item in sequences 1376~1500.
------------------------------
Code: 1101100C
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1501~1625).
Remedy: Check the X item in sequences 1501~1625.
------------------------------
Code: 1101100D
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1626~1750).
Remedy: Check the X item in sequences 1626~1750.
------------------------------
Code: 1101100E
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1751~1875).
Remedy: Check the X item in sequences 1751~1875.
------------------------------
Code: 1101100F
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 1876~2000).
Remedy: Check the X item in sequences 1876~2000.
------------------------------
Code: 11011010
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: Y data is out of range (sequences 0001~0125).
Remedy: Check the Y item in sequences 0001~0125.
------------------------------
Code: 11011011
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: Y data is out of range (sequences 0126~0250).
Remedy: Check the Y item in sequences 0126~0250.
------------------------------
Code: 11011012
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
第 13 页