FUJI错误代码查询.pdf - 第1561页

data. ------------------------------ Code: 1D2590?? Display: Used by: Cause: A lead pitch on the left side of the part is too wide. The final two digits indicate the lead number. Remedy: Check the part. Check the directi…

100%1 / 5282
Cause: A lead on the left side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2589??
Display:
Used by:
Cause: A lead on the left side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D258A??
Display:
Used by:
Cause: A lead on the lower side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D258B??
Display:
Used by:
Cause: A lead on the lower side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D258C??
Display:
Used by:
Cause: A lead on the right side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D258D??
Display:
Used by:
Cause: A lead on the right side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D258E??
Display:
Used by:
Cause: A lead on the upper side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D258F??
Display:
Used by:
Cause: A lead on the upper side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
第 1560 页
data.
------------------------------
Code: 1D2590??
Display:
Used by:
Cause: A lead pitch on the left side of the part is too wide. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2591??
Display:
Used by:
Cause: A lead pitch on the left side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2592??
Display:
Used by:
Cause: A lead pitch on the lower side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2593??
Display:
Used by:
Cause: A lead pitch on the lower side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2594??
Display:
Used by:
Cause: A lead pitch on the right side of the part is too wide. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2595??
Display:
Used by:
Cause: A lead pitch on the right side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2596??
Display:
Used by:
第 1561 页
Cause: A lead pitch on the upper side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D2597??
Display:
Used by:
Cause: A lead pitch on the upper side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25A0??
Display:
Used by:
Cause: A lead width on the left side of the part is too wide. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25A1??
Display:
Used by:
Cause: A lead width on the left side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25A2??
Display:
Used by:
Cause: A lead width on the lower side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25A3??
Display:
Used by:
Cause: A lead width on the lower side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25A4??
Display:
Used by:
Cause: A lead width on the right side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
第 1562 页