FUJI错误代码查询.pdf - 第1951页

------------------------------ Code: 2100762E Display: Can not setting Next device data Used by: Cause: As there are too many devices in use, the next device cannot be set. Remedy: Reduce the number of devices in use. --…

100%1 / 5282
Cause: The input program data type is inappropriate.
Remedy: Use the Editor to check the input program's machine type.
------------------------------
Code: 21007626
Display: Input program file expand error
Used by:
Cause: During expansion of the input program, an error occurred.
Remedy: Use [Cntrl] + [E] to check the contents of the expander.
------------------------------
Code: 21007627
Display: Part data file name get error
Used by:
Cause: A compatible Part data name has not been entered in the device number used by the sequence.
Remedy: Input a compatible Part data name into the program device data.
------------------------------
Code: 21007628
Display: Same davice comment entry in PST file
Used by:
Cause: A device comment with the same name exists in the PST file.
Remedy: The same name cannot be used. Change the comment.
------------------------------
Code: 21007629
Display: No entry Cartridge name in PST file
Used by:
Cause: The feeder name has not been entered in the PST file.
Remedy: Input the feeder name.
------------------------------
Code: 2100762A
Display: Can not feedback Fix device
Used by:
Cause: Unable to feed back the fixed device. The fixed device's device number is incorrect.
Remedy: Check the PST file device number.
------------------------------
Code: 2100762B
Display: Cartridge type unmatch
Used by:
Cause: The feeder type is incorrect.
Remedy: The feeder type described in Part data cannot be used. Input a different feeder type.
------------------------------
Code: 2100762C
Display: No used Cartridge
Used by:
Cause: An unused feeder exists. There is a feeder which does not use any sequences.
Remedy: This is a warning. It is all right to continue running the program if this situation is acceptable
to the user.
------------------------------
Code: 2100762D
Display: Can not setting Fix device data
Used by:
Cause: There is not enough space between the feeders.
Remedy: Change the PST file device number.
第 1950 页
------------------------------
Code: 2100762E
Display: Can not setting Next device data
Used by:
Cause: As there are too many devices in use, the next device cannot be set.
Remedy: Reduce the number of devices in use.
------------------------------
Code: 2100762F
Display: Next device not found
Used by:
Cause: The next device was not found.
Remedy: This message appears when there is no next device specified in the program.
------------------------------
Code: 21007630
Display: Cartridge name get error
Used by:
Cause: The feeder name is not input in the Device_name section of Sep_data in Part data.
Remedy: Check that the Part data has been entered correctly.
------------------------------
Code: 21007631
Display: Station over
Used by:
Cause: The device cannot be placed in the station.
Remedy: Join the feeders. Alternately, stop using the PST or the base program. Alternately, use fewer
devices.
------------------------------
Code: 21007632
Display: Occupancy data read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 21007633
Display: Slot info data read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 21007634
Display: New program file has no sequence
Used by:
Cause: There are no sequences in the new program file.
Remedy: Use the editor to check the input file.
------------------------------
Code: 21007635
Display: Parts height regulation over
Used by:
Cause: The part height exceeds the set limit.
Remedy: Check the Part data part height. It must be 4 mm or less on the FCP-II, and 6 mm or less on
other machines.
------------------------------
第 1951 页
Code: 21007636
Display: Different cartridge name in PST file
Used by:
Cause: The feeder name in the PST file is wrong.
Remedy: Check the PST file feeder name.
------------------------------
Code: 21007637
Display: PST file data type unmatch
Used by:
Cause: The PST file data type is incorrect.
Remedy: Use the Editor to check the file. If there are problems, recreate the file.
------------------------------
Code: 21007638
Display: Base program file data type unmatch
Used by:
Cause: The base program data type is incorrect.
Remedy: Use the Editor to check the file. If there are problems, recreate the file.
------------------------------
Code: 21007639
Display: Program file offset data read error
Used by:
Cause: Unable to read the file.
Remedy: Use the Editor to check the file. If there are problems, recreate the file.
------------------------------
Code: 2100763A
Display: Program file header read error
Used by:
Cause: Unable to read the file.
Remedy: Use the Editor to check the file. If there are problems, recreate the file.
------------------------------
Code: 2100763B
Display: Base program file read error
Used by:
Cause: Unable to read the file.
Remedy: Use the Editor to check the file. If there are problems, recreate the file.
------------------------------
Code: 2100763C
Display: Part data header read error
Used by:
Cause: Unable to read the file.
Remedy: Use the Editor to check the file. If there are problems, recreate the file.
------------------------------
Code: 2100763D
Display: Input program file not found
Used by:
Cause: Input program file was not found.
Remedy: Check the filename.
------------------------------
Code: 2100763E
Display: Input program file name is too long
Used by:
第 1952 页