FUJI错误代码查询.pdf - 第2100页
Code: 2100F009 Display: File load error Used by: Cause: The specified file could not be loaded to memory. Remedy: Re-execute the function. If the error recurs, re-install the software. ------------------------------ Code…
Remedy: Contact Fuji.
------------------------------
Code: 2100F001
Display: syntax error - illegal '+' option
Used by:
Cause: The '+' option was not specified correctly at start-up.
Remedy: Contact Fuji.
------------------------------
Code: 2100F002
Display: syntax error - illegal '-' option
Used by:
Cause: The '-' option was not specified correctly at start-up.
Remedy: Correct the input command if this error occurred due to a direct command.
------------------------------
Code: 2100F003
Display: syntax error - not found check file
Used by:
Cause: The object file to check was not specified correctly.
Remedy: Specify the object file correctly.
------------------------------
Code: 2100F004
Display: not found check file on disk
Used by:
Cause: The specified object file does not exist.
Remedy: Correct the name of the specified object file.
------------------------------
Code: 2100F005
Display: can't create output file
Used by:
Cause: The output file could not be created.
Remedy: Check the RAM for previously created files, and check that there is enough available memory.
Re-boot MCS.
------------------------------
Code: 2100F006
Display: can't create print file
Used by:
Cause: The printer file could not be created.
Remedy: There is insufficient RAM memory. Re-boot MCS.
------------------------------
Code: 2100F007
Display: Terminal path select error
Used by:
Cause: On start-up, the specified terminal path could not be selected to the standard I/O path.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100F008
Display: CRT event link error
Used by:
Cause: A terminal event could not be linked.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
第 2099 页
Code: 2100F009
Display: File load error
Used by:
Cause: The specified file could not be loaded to memory.
Remedy: Re-execute the function. If the error recurs, re-install the software.
------------------------------
Code: 2100F00A
Display: can't load file descriptor on memory
Used by:
Cause: The File Descriptor could not be loaded.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100F00B
Display: This check file is not a program
Used by:
Cause: The specified file is not a production program file.
Remedy: Specify the correct file name.
------------------------------
Code: 2100F00C
Display: can't open check table file
Used by:
Cause: The data check table could not be opened.
Remedy: Re-install the software.
------------------------------
Code: 2100F00D
Display: can't read check table data
Used by:
Cause: The data check table could not be read.
Remedy: Re-install the software.
------------------------------
Code: 2100F00E
Display: can't open Lp pipe
Used by:
Cause: The header information data check flag could not be written.
Remedy: Re-boot MCS.
------------------------------
Code: 2100F00F
Display: check flag rewrite error
Used by:
Cause: The data check flag could not be written to the header.
Remedy: Check that the file overwrite protect setting is not on.
------------------------------
Code: 2100F010
Display: Prog info: %s data over range
Used by:
Cause: The **** data in the program data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F011
Display: Prod mode: %s data over range
Used by:
第 2100 页
Cause: The **** data in the production mode data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F012
Display: M/C data: %s over range
Used by:
Cause: The **** data in the machine data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F013
Display: PCB data: %s over range
Used by:
Cause: The **** data in the PCB data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F014
Display: Mark data: %s out of range
Used by:
Cause: The **** data in the mark data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F015
Display: Dev data: %s over range
Used by:
Cause: The **** data in the device data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F016
Display: MB data: %s over range
Used by:
Cause: The **** data in the multi-block offset data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F017
Display: Seq data: %s over range
Used by:
Cause: The **** data in the sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F018
Display: Mark seq: %s over range
Used by:
Cause: The **** data in the fiducial mark reading sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F019
Display: Placing seq: %s over range
Used by:
Cause: The **** data in the placing sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------