FUJI错误代码查询.pdf - 第2103页
sequences). ------------------------------ Code: 2100F022 Display: Blk skip seq.Not found compare mark data Used by: Cause: The mark data referred to by the block-skip sequence does not exist. Remedy: Create the appropri…
Code: 2100F01A
Display: This program is over sequence
Used by:
Cause: The length of the sequence data exceeds the fixed limit.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01B
Display: This program is over device
Used by:
Cause: The length of the device data exceeds the fixed limit.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01C
Display: Duplicate mark number
Used by:
Cause: A fiducial number appears more than once in the sequence data.
Remedy: Contact Fuji.
------------------------------
Code: 2100F01D
Display: This sequence should be set before compare Mark seq
Used by:
Cause: A placing sequence appears before the mark reading sequence to which it refers in the sequence
data.
Remedy: Correct the position of the fiducial mark reading sequence in the sequence data.
------------------------------
Code: 2100F01E
Display: Duplicate mark number on block 0
Used by:
Cause: The mark number in the Block 0 fiducial mark sequence appears again somewhere else in the
sequence data.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01F
Display: Mark seq. on block0 should be set before compare seq
Used by:
Cause: The fiducial mark sequences in the Block 0 must appear before all other sequence data (except
the Block 0 block-skip sequences).
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F020
Display: Blk. skip seq: %s data over range
Used by:
Cause: The **** data in the block-skip sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F021
Display: Blk. skip seq. should be set before the others
Used by:
Cause: The block-skip sequences must appear before all other sequence data (except the block 0 fiducial
mark sequences).
Remedy: Place the block skip sequences in front of all others (except the block 0 fiducial mark
第 2102 页
sequences).
------------------------------
Code: 2100F022
Display: Blk skip seq.Not found compare mark data
Used by:
Cause: The mark data referred to by the block-skip sequence does not exist.
Remedy: Create the appropriate mark data.
------------------------------
Code: 2100F023
Display: Mark.seq.on block0 should be set before blk. skip seq
Used by:
Cause: The fiducial mark sequences in the Block 0 must appear before the block-skip sequences of all
blocks except Block 0.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F024
Display: D_No. PD **** Undefined part sort on PDG
Used by:
Cause: The **** data in the Part Data does not exist.
Remedy: Create the appropriate Part Data.
------------------------------
Code: 2100F025
Display: Placing seq: Undefined MM data
Used by:
Cause: The main fiducial mark is not specified in the placing sequence (when using the fiducial marks).
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F026
Display: Placing seq: Not found compare device data
Used by:
Cause: The device data referred to by a placing sequence does not exist.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F027
Display: This program M/C type is not supported
Used by:
Cause: The machine type specified in the production program is not supported.
Remedy: Correct the machine type.
------------------------------
Code: 2100F028
Display: Not found '+' option
Used by:
Cause: The '+' option was not specified at start-up.
Remedy: Contact Fuji.
------------------------------
Code: 2100F029
Display: Undefined device part name
Used by:
Cause: The part data name is not specified for a component.
Remedy: Correct the appropriate data.
------------------------------
第 2103 页
Code: 2100F02A
Display: Mark seq. not found compare mark data
Used by:
Cause: The fiducial mark data referred to by a fiducial mark reading sequence does not exist.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F02B
Display: Check flag data read error
Used by:
Cause: The data check flag could not be read from the header.
Remedy: Use the editor to check that the file is correct.
------------------------------
Code: 2100F02C
Display: x, y data overflow PCB range
Used by:
Cause: A sequence data X or Y value exceeds the permitted range for the board.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F02D
Display: Blk0 mount seq and except Blk0 seq intermingled
Used by:
Cause: Placing sequences for Block 0 and placing sequences for other blocks are mixed together.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F02E
Display: Undefined M/C type data on check table
Used by:
Cause: The specified machine type data does not exist in the data check table.
Remedy: Contact Fuji.
------------------------------
Code: 2100F02F
Display: Bskip0 seq. should be set before the others bskip seq
Used by:
Cause: The block skip sequences in Block 0 must appear before the block-skip sequences of all blocks
except Block 0.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F030
Display: Working mode no much to machine type
Used by:
Cause: The sequence type and machine type do not match.
Remedy: Check the sequence type of the sequence in question. The FGL-2 uses D,F, G, T and B. The
GSP-2 uses D, F and M sequences. The FEP-20 uses D and B sequences. The FEPGL and FGL use D and
T sequences. Other machines use D, F and B sequences.
------------------------------
Code: 2100F031
Display: Mark_type data error in mark_data
Used by:
Cause: The mark type and the sequence type are not the same.
Remedy: Check that the mark type and the sequence type are the same type.
------------------------------