FUJI错误代码查询.pdf - 第2126页
Code: 2300E003 Display: Data contains invalid characters. [item name]. Used by: Cause: An illegal character was entered. Remedy: Select the setting item where the error occurred to display the illegal character at the bo…
Used by:
Cause: Invalid production program data has been downloaded.
(i.e., The program with more than 100 slots is downloaded to XP141.)
Remedy: Check to see if the slot number and stage number are correcet.etc.
------------------------------
Code: 23004003
Display: Failed to receive the program.
Used by:
Cause: Failed to receive the program.
Remedy: Transmit the program from MCS/2 again.
------------------------------
Code: 23004004
Display: There is no response from MCS/2.
Used by:
Cause: There is no response from MCS/2 for MCS-X data requiring signal.
Setting for cables or ports may be incorrect.
Remedy: Check to see if the cables and ports are fine, then transmit the data from MCS/2 again.
------------------------------
Code: 23005007
Display: Select the log files in succession.
Used by:
Cause: The selected log files in the displayed list are not in succession.
Remedy: Select log files in succession.
------------------------------
Code: 23005008
Display: Unable to create an error code table.
Used by:
Cause: An error code table could not be created.
Remedy: Check whether the XP error code file exists
>>(Install folder)\System\XP_ENG.ERR
If this file does not exist, it is necessary to reinstall the software.
------------------------------
Code: 23005009
Display: A program necessary for totalisation does not exist. [File Name] Continue with calculation?
Used by:
Cause: The program required for log file tabulation does not exist in the specified folder.
Remedy: Obtain the required program from the XP machine, and save the program in the specified folder.
------------------------------
Code: 2300E001
Display: Range error [item name].
Used by:
Cause: A value which exceeds the permissible input range was entered.
Remedy: Enter a value within the permissible input range.
------------------------------
Code: 2300E002
Display: Number of permissible characters exceeded. [item name].
Used by:
Cause: The number of entered characters exceeded the permissible number.
Remedy: Select the setting item where the error occurred to display the permissible number of characters
(input range) at the bottom of the window, then revise the setting data so that this range is not exceeded.
------------------------------
第 2125 页
Code: 2300E003
Display: Data contains invalid characters. [item name].
Used by:
Cause: An illegal character was entered.
Remedy: Select the setting item where the error occurred to display the illegal character at the bottom of
the window, then revise the data accordingly.
------------------------------
Code: 2300E004
Display: No data exists. [item name].
Used by:
Cause: No setting has been specified.
Remedy: Specify a setting.
------------------------------
Code: 2300E102
Display: 'Position X' exceeds the range of the panel.
Used by:
Cause: The sequence data's X-coordinate is off the panel.
Remedy: Specify an X-coordinate which is within the panel size range.
------------------------------
Code: 2300E103
Display: 'Position Y' exceeds the range of the panel.
Used by:
Cause: The sequence data's Y-coordinate is off the panel.
Remedy: Specify an Y-coordinate which is within the panel size range.
------------------------------
Code: 2300E104
Display: Stage number has not been specified.
Used by:
Cause: The stage number has been set.
Remedy: Specify the stage number of the part to be mounted.
------------------------------
Code: 2300E105
Display: Slot number has not been specified.
Used by:
Cause: The slot number has not been set.
Remedy: Specify the slot number of the part to be mounted.
------------------------------
Code: 2300E106
Display: No data has been specified in stage number/slot number.
Used by:
Cause: No setting data exists for the stage number and slot number specified in the sequence data.
Remedy: Either specify settings for the stage number and slot number in the feeder setup data, or specify
a stage number and slot number for which setting data already exists.
------------------------------
Code: 2300E107
Display: Mark number has not been specified.
Used by:
Cause: The mark number in the fiducial mark reading sequence is set as "0".
Remedy: Specify a mark number setting other than "0".
------------------------------
Code: 2300E108
第 2126 页
Display: There are sequences on the same board with the same mark number.
Used by:
Cause: A fiducial mark reading sequence exists which has duplicate mark numbers within a single
board.
Remedy: Revise either the "Board No." or "Mark No." in the sequence data.
------------------------------
Code: 2300E109
Display: Main mark number has not been set.
Used by:
Cause: The main mark number in the part placement sequence is set as "0".
Remedy: Specify a main mark number setting other than "0".
------------------------------
Code: 2300E10A
Display: Sub mark number has not been set.
Used by:
Cause: The sub-mark number in the part placement sequence is set as "0".
Remedy: Specify a sub-mark number setting other than "0".
------------------------------
Code: 2300E10B
Display: The main mark and sub mark numbers are identical.
Used by:
Cause: The same setting value is specified for both the main mark number and the sub-mark number in
the part placement sequence.
Remedy: Specify setting values so that the main mark number and sub-mark number are different.
------------------------------
Code: 2300E10C
Display: The fiducial mark sequence for the mark number set as the main mark cannot be found.
Used by:
Cause: A fiducial mark reading sequence which contains the specified (in the part placement sequence)
main mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified main mark number to occur before the
part placement sequence.
------------------------------
Code: 2300E10D
Display: The fiducial mark sequence for the mark number set as the sub mark cannot be found.
Used by:
Cause: A fiducial mark reading sequence which contains the specified (in the part placement sequence)
sub-mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified sub-mark number to occur before the
part placement sequence.
------------------------------
Code: 2300E10E
Display: Board skip settings of '0' and '1' have both been specified in the sequence data for the same
board.
Used by:
Cause: Sequence data with and without board skip settings exist for the same board.
Remedy: Correct the sequence data so that all sequences for the same board have the same board skip
settings.
------------------------------
Code: 2300E10F
Display: Feeder skip settings of '0' and '1' have both been specified in the sequence data for the same
第 2127 页