FUJI错误代码查询.pdf - 第206页

Display: Used by: Cause: The pallet is being changed (PCM/PPS) so the device lock is disabled. Remedy: The device lock cannot be used while the pallet is being changed. ------------------------------ Code: 1107BF10 Displ…

100%1 / 5282
Display:
Used by:
Cause: Tray pickup point change indicator T number error.
Remedy: Enter the correct T number for the correct tray.
------------------------------
Code: 1107BF08
Display:
Used by:
Cause: Tray pickup point change indicator # number error.
Remedy: Enter the correct # number for the correct tray.
------------------------------
Code: 1107BF09
Display:
Used by:
Cause: In automatic operation mode, the device mode and original axis cannot change.
Remedy: To change device mode or original axis, interrupt automatic operation mode and perform the
change.
------------------------------
Code: 1107BF0A
Display:
Used by:
Cause: During inching axis change, the machine does not have that mode.
Remedy: Use the correct inching axis.
------------------------------
Code: 1107BF0B
Display:
Used by:
Cause: In automatic operation mode, the device mode and original axis cannot change.
Remedy: To change device mode or original axis, interrupt automatic operation mode and perform the
change.
------------------------------
Code: 1107BF0C
Display:
Used by:
Cause: Because the number of devices in the production program is large, the machine can only operate
in joint mode.
Remedy: Put the machine into joint mode.
------------------------------
Code: 1107BF0D
Display:
Used by:
Cause: Because the Handy Terminal is in use, that request cannot be mode.
Remedy: Wait until after the Handy Terminal is finished.
------------------------------
Code: 1107BF0E
Display:
Used by:
Cause: In automatic operation, device lock cannot change.
Remedy: To remove the device lock interrupt automatic operation.
------------------------------
Code: 1107BF0F
第 205 页
Display:
Used by:
Cause: The pallet is being changed (PCM/PPS) so the device lock is disabled.
Remedy: The device lock cannot be used while the pallet is being changed.
------------------------------
Code: 1107BF10
Display:
Used by:
Cause: While downloading device data, the correct data was not downloaded.
Remedy: Download the device data.
------------------------------
Code: 1107BF11
Display:
Used by:
Cause: Cannot perform device check.
Remedy: None.
------------------------------
Code: 1107BF20
Display:
Used by:
Cause: Invalid parameter value.
Remedy: None.
------------------------------
Code: 1107BF30
Display:
Used by:
Cause: The pickup point cannot change in automatic operation.
Remedy: To change the pickup point, interrupt automatic operation.
------------------------------
Code: 1107BF31
Display:
Used by:
Cause: Program cannot be changed.
Remedy: None.
------------------------------
Code: 1107BF40
Display:
Used by:
Cause: With the Handy Terminal in device check, the specified device check was rejected.
Remedy: None.
------------------------------
Code: 1107BF41
Display:
Used by:
Cause: Because the start button was pressed previously, the reset switch is ineffective.
Remedy: None.
------------------------------
Code: 1107BF42
Display:
Used by:
Cause: The command was rejected because the machine is changing programs.
第 206 页
Remedy: Check that the machine has finished changing programs and then input the command.
------------------------------
Code: 1107BF43
Display:
Used by:
Cause: Program is ineffective.
Remedy: None.
------------------------------
Code: 1107BF50
Display:
Used by:
Cause: The command was rejected because the machine was in device check.
Remedy: After device check is finished, re-enter the command.
------------------------------
Code: 1107BF60
Display:
Used by:
Cause: Processing was interrupted because the pallet number is ineffective.
Remedy: Check the pallet numbers in the production program.
------------------------------
Code: 1107BF61
Display:
Used by:
Cause: Processing was interrupted because the pallet number was not specified.
Remedy: Set the pallet number in the production program.
------------------------------
Code: 1107C001
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C001 ID:* E:??
Used by: QP132
Cause: The completion code for the response from the ID reader is not normal.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
??: Finishing code.
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C002
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C002 ID:*
Used by: QP132
Cause: The text that has been received cannot be analyzed.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C003
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C003 ID:*
Used by: QP132
Cause: Transmission time out error has occurred.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
第 207 页