FUJI错误代码查询.pdf - 第871页
Cause: Momentary maximum torque. Operation was performed for several seconds at significantly over the rated torque. Remedy: Check to ensure that there is no interference or that the axis movement is not impeded. In addi…
Used by:
Cause: Matching error. The motor and servo pack capacities do not match.
Remedy: Check to make sure that there are no wiring problems.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110034
Display: Servo amplifier error.
Used by:
Cause: Current overload or the heat sink is too hot. The current meter has detected a surge, or the servo
pack's heat sink is too hot.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Contact Fuji if no errors are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110035
Display: Servo amplifier error.
Used by:
Cause: Regenerative error. Either the regenerative resistance wiring is disconnected, or a regenerative
transistor is damaged.
Remedy: Contact Fuji, because it is possible that the servo amplifier is damaged.
------------------------------
Code: 12110036
Display: Servo amplifier error.
Used by:
Cause: Regenerative overload. The regenerative energy is more than the regenerative resistance capacity.
Remedy: The axis rotating speed is too fast, or the regenerative resistance capacity is incorrect.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110037
Display: Servo amplifier error.
Used by:
Cause: Overvoltage. The base DC voltage is abnormally high.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110038
Display: Servo amplifier error.
Used by:
Cause: Undervoltage. The base DC voltage is too low.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110039
Display: Servo amplifier error.
Used by:
Cause: Acceleration rate. The motor is rotating abnormally high.
Remedy: The speed setting could be abnormally high. Check the parameter settings.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003a
Display: Servo amplifier error.
Used by:
第 870 页
Cause: Momentary maximum torque. Operation was performed for several seconds at significantly over
the rated torque.
Remedy: Check to ensure that there is no interference or that the axis movement is not impeded. In
addition, check to ensure that none of the motor power lines are broken (U,V,W), or that there are no
shorts.
------------------------------
Code: 1211003b
Display: Servo amplifier error.
Used by:
Cause: DB overload. During dynamic braking, the rotational energy is more than the DB resistance
capacity.
Remedy: The emergency stop process could be incorrect. If this occurs frequently, contact Fuji.
------------------------------
Code: 1211003c
Display: Servo amplifier error.
Used by:
Cause: Initial resistance overload. The base power has been repeatedly turned on and off.
Remedy: Check for a short in the power line, or if the wire is broken, when this condition occurs.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003d
Display: Servo amplifier error.
Used by:
Cause: Heat sink is too hot. The heat sink for the servo pack is too hot.
Remedy: Check for abnormalities in the base circuitry or in the wiring for the motor power.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003e
Display: Servo amplifier error.
Used by:
Cause: Encoder feedback error. Information from the encoder is abnormal.
Remedy: Check for breaks in the encoder wiring, or for bad connections.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003f
Display: Servo amplifier error.
Used by:
Cause: Erratic movement detected. Motor was out of control.
Remedy: Check the base circuit wiring, motor power wiring, and encoder wiring for any abnormalities.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110040
Display: Servo amplifier error.
Used by:
Cause: Positioning deviation is too large. Positioning deviation pulse was over the set value.
Remedy: Check to ensure that the deviation setting is appropriate.
Investigate the reason for it being out of control.
------------------------------
Code: 12110041
Display: Servo amplifier error.
Used by:
第 871 页
Cause: Power out of phase. One of the three phases for the power is not connected.
Remedy: Check to ensure that all wires for the three phases are not broken, or have any shorts.
------------------------------
Code: 12110042
Display: Servo amplifier error.
Used by:
Cause: Watch dog error. Abnormal SERCOS communication has occurred.
Remedy: Check to ensure that the digital operator is not connected.
Contact Fuji if this occurs frequently, because the SERCOS unit could be damaged.
------------------------------
Code: 12110043
Display: Servo amplifier error.
Used by:
Cause: MST, MDT error. SERCOS communication is abnormal.
Remedy: Check the fiber optic connections and make sure the digital operator is not connected.
Contact Fuji if no abnormalities are found, because the SERCOS board could be damaged.
------------------------------
Code: 12110044
Display: Boot timeout.
Used by:
Cause: RTX Servo filter execution file is timeout of boot.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110045
Display: The magnetic pole detection failure.
Used by:
Cause: The execution of the Detected Magnet Pole is timeout.
Remedy: Check to ensure that the linear motor axis is no interference or that the axis movement is not
impeded.
------------------------------
Code: 12110046
Display: Program error.
Used by:
Cause: The specified function is effective only with the linear motor.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110047
Display: The magnetic pole detection failure.
Used by:
Cause: It has executed magnetic pole detection.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110048
Display: Program error.
Used by:
Cause: An indicated axis is registered on the other operation control at present.
Remedy: There is possibility that version up isn't correct.Reinstall the recovery media software.
------------------------------
Code: 12110049
Display: System error.
Used by:
第 872 页