FUJI错误代码查询.pdf - 第791页
------------------------------ Code: 12078?82 Display: "PMC?(ICM,SCU?) Error Code:********" (QP2) "Abs. Encoder Checksum Err" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP…
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack software version error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Servopack replacement may be necessary.
------------------------------
Code: 12078?71
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Overload (Momentary)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Momentary overload of Y-axis servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, or whether the axis action has become
extremely heavy. Check whether the motor power wires (U, V, and W) have become broken or short-
circuited.
------------------------------
Code: 12078?72
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Overload (Continuous)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Continuous overload of Y-axis servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, or whether the axis action has become
extremely heavy. Check whether the motor power wires (U, V, and W) have become broken or short-
circuited.
------------------------------
Code: 12078?80
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Absolute Encoder Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack encoder error (for the absolute value encoder only).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, or whether the axis action has become
extremely heavy. Check whether the motor power wires (U, V, and W) have become broken or short-
circuited.
------------------------------
Code: 12078?81
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Abs. Encoder Backup Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Y-axis servopack encoder backup error (for the 12-bit absolute value encoder only).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
第 790 页
------------------------------
Code: 12078?82
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Abs. Encoder Checksum Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack encoder checksum error (for the 12-bit absolute value encoder only).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12078?83
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Abs. Encoder Battery Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack battery error (for the absolute value encoder only).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12078?84
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Abs. Encoder Abs. Value Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack encoder absolute value error (for the 12-bit absolute value encoder only).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12078?85
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Abs. Encoder Overspeed" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack encoder excessive speed error (for the 12-bit absolute value encoder only).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12078?90
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Blew Fuse" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack fuse has blown.
第 791 页
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Servopack replacement may be necessary.
------------------------------
Code: 12078?B1
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Gate Array 1 Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack gate array 1 error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Servopack replacement may be necessary.
------------------------------
Code: 12078?B2
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Gate Array 2 Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack gate array 2 error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Servopack replacement may be necessary.
------------------------------
Code: 12078?B3
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Current Fdback Errr/Phase U" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack current feedback error in phase U.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the motor power wire (phase U) has become broken or short-circuited.
------------------------------
Code: 12078?B4
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Current Fdback Errr/Phase V" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servopack current feedback error in phase V.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the motor power wire (phase V) has become broken or short-circuited.
------------------------------
Code: 12078?B5
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Watch-dog Circuit Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Y-axis servopack watchdog detection circuit error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 792 页