------------------------------ Code: 1101D092 Display: Used by: IP3 Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This applies to sequences 101 to 300. Remedy: Check the s…
Display:
Used by:
Cause: The tray thickness has not been specified. This error refers to device numbers 301 to 500.
Remedy: Input correct data into the 25.(Tray:)Rack_pitch item in Part data's
Package_and_appearance_data.
------------------------------
Code: 1101D08C
Display:
Used by: IP3
Cause: The tray thickness is larger than the magazine rack pitch. This error refers to device numbers
101 to 300.
Remedy: Input correct data into the 24.(Tray:)Tray_thickness_x and 25.(Tray:)Rack_pitch items in Part
data's Package_and_appearance_data.
------------------------------
Code: 1101D08D
Display:
Used by:
Cause: The tray thickness is larger than the magazine rack pitch. This error refers to device numbers
301 to 500.
Remedy: Input correct data into the 24.(Tray:)Tray_thickness_x and 25.(Tray:)Rack_pitch items in Part
data's Package_and_appearance_data.
------------------------------
Code: 1101D08E
Display:
Used by: IP3
Cause: The number of steps in the magazine rack has not been specified. This error refers to device
numbers 101 to 300.
Remedy: Input correct data into the 26.(Tray)Rack_steps item in Part data's
Package_and_appearance_data.
------------------------------
Code: 1101D08F
Display:
Used by:
Cause: The number of steps in the magazine rack has not been specified. This error refers to device
numbers 301 to 500.
Remedy: Input correct data into the 26.(Tray)Rack_steps item in Part data's
Package_and_appearance_data.
------------------------------
Code: 1101D090
Display:
Used by: IP3
Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This
applies to sequences 101 to 300.
Remedy: Check the setting in Package_and_appearance_data's 21.(Tray:)Tray_pickup_pnt_x.
------------------------------
Code: 1101D091
Display:
Used by:
Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This
applies to sequences 301 to 500.
Remedy: Check the setting in Package_and_appearance_data's 21.(Tray:)Tray_pickup_pnt_x.
第 103 页
------------------------------
Code: 1101D092
Display:
Used by: IP3
Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This
applies to sequences 101 to 300.
Remedy: Check the setting in Package_and_appearance_data's 21.(Tray:)Tray_pickup_pnt_y.
------------------------------
Code: 1101D093
Display:
Used by:
Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This
applies to sequences 301 to 500.
Remedy: Check the setting in Package_and_appearance_data's 21.(Tray:)Tray_pickup_pnt_y.
------------------------------
Code: 1101D094
Display:
Used by: IP3
Cause: The vision processing system's vision type has not been specified. This applies to sequences 1 to
50.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D095
Display:
Used by:
Cause: The vision processing system's vision type has not been specified. This applies to sequences 51
to 100.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D096
Display:
Used by:
Cause: The vision processing system's vision type has not been specified. This applies to sequences 101
to 300.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D097
Display:
Used by:
Cause: The vision processing system's vision type has not been specified. This applies to sequences 301
to 500.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D098
Display: 1101D098
Used by: IP3
Cause: The length of the pin on the bottom of the part for which flux is to be applied has been specified
in Alignment_pin_length. This error has occurred because of the risk of interference during the flux
application, between the bottom of the flux receptacle and the pin on the bottom of the part.
Remedy: After correcting the part data item in question, transmit the production program again.
------------------------------
第 104 页
Code: 1101D099
Display: Same as code
Used by: IP2
Cause: A pre-rotation setting is included in the device data for a device using a rectangular nozzle. Pre-
rotation cannot be performed by an IP2 using a rectangular nozzle.
Remedy: The pre-rotation setting in the device data will be ignored when a rectangular nozzle is used. To
use pre-rotation, change the nozzle.
------------------------------
Code: 1101D09A
Display: Same as code
Used by: IP2
Cause: A 90[deg] rotation pickup setting is included in the device data for a device using a rectangular
nozzle. A 90[deg] rotation pickup cannot be performed by an IP2 using a rectangular nozzle.
Remedy: The 90[deg] rotation pickup setting in the device data will be ignored when a rectangular nozzle
is used. To use the 90[deg] rotation pickup function, change the nozzle.
------------------------------
Code: 1101D09B
Display: Same as code
Used by: IP2
Cause: A lead coplanarity check setting is included in the device data for a device using a rectangular
nozzle. A lead coplanarity check cannot be performed by an IP2 using a rectangular nozzle.
Remedy: The lead coplanarity check setting in the device data will be ignored when a rectangular nozzle is
used. To use the lead coplanarity check function, change the nozzle.
------------------------------
Code: 1101D09C
Display: Same as code
Used by:
Cause: The value of the "Package_and_appearance_data:Tray_pick_pnt_x_IP" parameter in the Part data
has exceeded the remover's movement range in the X-axis direction. This error occurs in devices 101
through 120.
Remedy: Set this parameter to a value from -1 to -125.
------------------------------
Code: 1101D09D
Display: Same as code
Used by:
Cause: The value of the "Package_and_appearance_data:Tray_pick_pnt_y_IP" parameter in the Part data
has exceeded the remover's movement range in the Y-axis direction. This error occurs in devices 101 to
120.
Remedy: Set this parameter to a value from -1 to -250.
------------------------------
Code: 1101D1??
Display: Same as code
Used by: IP1
Cause: A value input for the notch check coordinates has exceeded the valid range (on the FIP-1 or -2).
The value replacing the "??" in the code is the device number.
Remedy: Make sure that values from -12.7 to 12.7 [mm] have been set for these Part data parameters:
"Fst_pin_check_data", "3.Fst_pin_check_area_x1", and "4.Fst_pin_check_area_y1".
------------------------------
Code: 1101D200
Display: 不是joint模式时、不能在供料器安装数据中进行供料平台2的设定。
Used by: XP141,XP142
第 105 页