FUJI错误代码查询.pdf - 第227页

the MTU and IP, the data may be corrupted. ------------------------------ Code: 11100000 Display: Parser process error! Used by: CP732 Cause: In a parser process, the malfunction which it is impossible to recover occurre…

100%1 / 5282
Remedy: Input a value between 0 to 50.0(mm) in the Part data item MTU Rack Pitch.
------------------------------
Code: 11083381
Display: Magazine rack step value out of range
Used by: MTU4
Cause: The specified MTU rack step value is out of range.
Remedy: Input a value between 0 to 10(steps) in the Part data item MTU Rack Step.
------------------------------
Code: 11083390
Display: Carrier offset out of range
Used by: MTU4
Cause: The specified Carrier offset R or Carrier offset L value is out of range.
Remedy: Input a value between -300.00 to 300.00 in the Part data item Carrier Offset R or Carrier Offset
L.
------------------------------
Code: 11083410
Display: Pickup Pos. Out of Range
Used by: MTU3,MTU4,MTU5
Cause: The pick up position specified for tray parts at the IP machine, exceeds the range set in part data.
Remedy: Specify a pick up point within the range.
------------------------------
Code: 11088010
Display: Transmission Format Error Or No Initial Response From MTU
Used by: MTU3,MTU4,MTU5
Cause: When the MTU and IP communicated, there was no initial response from the MTU or the data
was of the wrong format. Transmission was attempted 3 times but there was no correct reply.
Remedy: Check that the cable connecting the MTU and the IP machine is not disconnected and that there
are no problems with the contacts in the connector. Furthermore, if there is a machine generating a
strong magnetic field near the communication path, the data may be corrupted.
------------------------------
Code: 11088031
Display: No Initial Response From MTU
Used by: MTU3,MTU4,MTU5
Cause: Although communication was attempted 3 times, there was no correct initial response from the
MTU.
Remedy: Check that the cable connecting the MTU and the IP machine is not disconnected and that there
are no problems with the contacts in the connector.
------------------------------
Code: 11088032
Display: Initial Response Received / No Complete Report From MTU
Used by: MTU3,MTU4,MTU5
Cause: When a cycle stop instruction, zero set instruction etc was sent from the IP machine to the MTU,
a complete report was not returned from the MTU.
Remedy: Reset the error at the IP machine. If the error occurs frequently, contact Fuji.
------------------------------
Code: 11088200
Display: Transmission Format Error At Complete Report From MTU
Used by: MTU3,MTU4,MTU5
Cause: When a complete report was sent from the MTU in response to a cycle stop or zero set command,
the transmitted data was not in the prescribed format.
Remedy: If there is a machine generating a strong magnetic field near the communication cable joining
第 226 页
the MTU and IP, the data may be corrupted.
------------------------------
Code: 11100000
Display: Parser process error!
Used by: CP732
Cause: In a parser process, the malfunction which it is impossible to recover occurred.
Remedy: Acquire and deliver a trace data to FUJI with the information of the occurrence situation.
Do shutdown.
------------------------------
Code: 11100001
Display: File error!
Used by: CP732
Cause: It failed in the file operation.For the details, you refer to the error panel on the machine.
Remedy: You refer to the error panel on the machine.
------------------------------
Code: 11100002
Display: Data checking error!
Used by: CP732
Cause: The data checking error occurred by the reading processing or by the writing processing of a file.
For the details, you refer to the error panel on the machine.
Remedy: You refer to the error panel on the machine.
------------------------------
Code: 11100101
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the selected program.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100102
Display: File save error!
Used by: NP2,QP3
Cause: Failed to write the program to the hard disk:
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100103
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a program file.
Remedy: Download the required program file and select it using the [Program] command.
------------------------------
Code: 11100104
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the program file.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100105
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range.
Remedy: Select the [Program Editor] command to edit the program.
第 227 页
Alternatively, download an uncorrupted program and select it using the [Program] command.
------------------------------
Code: 11100106
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the program file.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100107
Display: Nozzle(s) missing!
Used by: NP2,QP3
Cause: Cannot find the nozzles specified in the program.
Remedy: Insert the required nozzles in the station and use the [Nozzle Settings] command to make the
required changes.
------------------------------
Code: 11100108
Display: Nozzle name consistency error!
Used by: NP2,QP3
Cause: The nozzles specified in the program are missing from the NAT file.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
Alternatively, download an uncorrupted NAT file and restart the machine.
------------------------------
Code: 11100109
Display: Nozzle name consistency error!
Used by: NP2,QP3
Cause: The nozzle station name specified in the program differs from that in memory.
Remedy: Exchange the nozzle station or use the [Update] command to update machine memory.
Note: Production with a different nozzle station is possible as long as the required nozzles are
available.
------------------------------
Code: 1110010A
Display: Nozzle station consistency error!
Used by: NP2,QP3
Cause: The nozzle station specified in the program are missing from the nozzle station file.
Remedy: Download an uncorrupted program file and select it usiAlternatively, download an uncorrupted
nozzle station file and restart the machine.
------------------------------
Code: 1110010B
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Failed to close next device loop.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010C
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: The next device slot exceeds the number available at the specified stage.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010D
Display: Production program data mismatch.
第 228 页