Code: 1207F?47 Display: "SCU?(ICM,PMC?) Error Code:********" "TY-Axis Servo Alarm Transmission Timeout" Used by: QP242 Cause: The command's first character was not input within the specified time…

100%1 / 5282
malfunctions of the communication board or the RB controller.
------------------------------
Code: 1207F?42
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm During Axis Movement"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?43
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Protocol Error"
Used by: QP242
Cause: A protocol error (a parity error, framing error, or an overrun error) occurred while receiving data.
The RB unit ALM light is on.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation. It is possible that the cable, communication board, or
RB controller is faulty.
------------------------------
Code: 1207F?44
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Disconnected Axis"
Used by: QP242
Cause: TY-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?45
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit. The ALM lamp on the RB unit
will light when this error occurs. (If the new RB unit is being used, an amp driver alarm will be indicated.)
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. (If the new RB unit is being used, check the amp driver power
supply.)
------------------------------
Code: 1207F?46
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Controller Processing"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
第 843 页
Code: 1207F?47
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The command's first character was not input within the specified time (30 ms).
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?48
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The time between characters exceeds 100 ms.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?49
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?4A
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Axis Alarm Still Occuring"
Used by: QP242
Cause: A command was received before the machine was reset.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?4B
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?50
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Comm Error"
Used by: QP242
Cause: Cannot communicate with the servo unit.
"?" indicates the module number (QP2).
第 844 页
"****" indicates the error code.
Remedy: Check that the servo unit is properly connected.
------------------------------
Code: 1207F?51
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?52
Display: "SCU?(PMC?,ICM) Error Code:********"
"The TY-Axis Servo is OFF or an alarm is active."
Used by: QP242
Cause: The TY-axis servo is off or an alarm is active.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: If the TY-axis servo is off, check that the servo controller is being supplied with power. If an
alarm is active, clear the alarm and restart operation.
------------------------------
Code: 1207F?53
Display: "SCU?(PMC?,ICM) Error Code:********"
"A TY-axis servo parameter have not been set."
Used by: QP242
Cause: Check the parameters for the TY-axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Set the TY-axis servo parameters, supply power and restart operation.
------------------------------
Code: 1207F?54
Display: "SCU?(PMC?,ICM) Error Code:********"
"Cancellation by TY-Axis stop command."
Used by: QP242
Cause: Axis operation terminated because a separate error occurred during communication.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?55
Display: "SCU?(PMC?,ICM) Error Code:********"
"Error prior to TY-Axis Encorder Counter Operation"
Used by: QP242
Cause: The machine attempted to take an encoder count before the current count had been confirmed.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?56
Display: "SCU?(PMC?,ICM) Error Code:********"
第 845 页