FUJI错误代码查询.pdf - 第193页
Used by: IP2 Cause: There are no parts in the specified tray. Remedy: Resupply the tray with parts. ------------------------------ Code: 11074250 Display: Used by: Cause: There is no tray. Remedy: Supply a new tray. ----…
------------------------------
Code: 11074145
Display:
Used by: IP2
Cause: Overtravel T+ NG
Remedy: Move the appropriate part of the machine away from the overtravel sensor.
------------------------------
Code: 11074146
Display:
Used by: IP2
Cause: Overtravel T- NG
Remedy: Move the appropriate part of the machine away from the overtravel sensor.
------------------------------
Code: 11074150
Display:
Used by: IP2
Cause: The 200V power supply was not on.
Remedy: Turn on the 200V power supply.
------------------------------
Code: 11074200
Display:
Used by: IP2
Cause: MTU is in OFF_LINE mode.
Remedy: Put MTU into ON_LINE mode.
------------------------------
Code: 11074201
Display:
Used by: IP2
Cause: MTU is in ON_LINE mode.
Remedy: Put MTU into OFF_LINE mode.
------------------------------
Code: 11074210
Display:
Used by:
Cause: Proper data could not be transmitted to the MTU.
Remedy: Retransmit Proper data.
------------------------------
Code: 11074220
Display:
Used by: IP2
Cause: Zero setting was not properly finished.
Remedy: Re-perform zero setting.
------------------------------
Code: 11074230
Display:
Used by: IP2
Cause: The specified tray number is out of range.
Remedy: Check the tray specifications.
------------------------------
Code: 11074240
Display:
第 192 页
Used by: IP2
Cause: There are no parts in the specified tray.
Remedy: Resupply the tray with parts.
------------------------------
Code: 11074250
Display:
Used by:
Cause: There is no tray.
Remedy: Supply a new tray.
------------------------------
Code: 11074260
Display:
Used by:
Cause: The tray was not ejected.
Remedy: Eject the tray.
------------------------------
Code: 11074270
Display:
Used by: IP2
Cause: The SY axis is not in the safety position.
Remedy: Move the SY axis into the safety position.
------------------------------
Code: 11074280
Display:
Used by: IP2
Cause: Machine can not go into ON_LINE while inching.
Remedy: Wait until after inching is finished.
------------------------------
Code: 11074290
Display:
Used by: IP2
Cause: The carrier and nozzle are full.
Remedy: Remove parts from the carrier and nozzle.
------------------------------
Code: 110742A0
Display:
Used by: IP2
Cause: Parts request command error (not P, I or S).
Remedy: None.
------------------------------
Code: 110742B0
Display:
Used by: IP2
Cause: The specified X position is out of range.
Remedy: None.
------------------------------
Code: 110742B1
Display:
Used by: IP2
Cause: The specified Y position is out of range.
Remedy: None.
第 193 页
------------------------------
Code: 110742C0
Display:
Used by:
Cause: The sub-nozzle dropped the part.
Remedy: Pick the part again.
------------------------------
Code: 110742D0
Display:
Used by: IP2
Cause: Tray set error. The tray is not set correctly.
Remedy: Set the tray correctly.
------------------------------
Code: 110742E0
Display:
Used by: IP2
Cause: The tray is not in its original position.
Remedy: Return the tray to its original position.
------------------------------
Code: 110742F0
Display:
Used by: IP2
Cause: The tray chute is not set.
Remedy: Set the tray chute.
------------------------------
Code: 11074300
Display:
Used by: IP2
Cause: Proper data's X axis travel time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074301
Display:
Used by: IP2
Cause: Proper data's Y axis travel time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074302
Display:
Used by: IP2
Cause: Proper data's T axis travel time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074303
Display:
Used by: IP2
Cause: Proper data's X axis deceleration point is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074304
Display:
第 194 页