Code: 1206104A Display: NY-axis start processing error Used by: CP-8Series Cause: An NY-axis start signal was output while in error status. Remedy: Correct the cause of the error, and push READY ON. ---------------------…

100%1 / 5282
number has been specified correctly at the [Parts Administration System] setting screen.
------------------------------
Code: 12061041
Display: Feeder type error.
Used by: QP3
Cause: In the production program, sub-slot "1" or "2" has been specified for a feeder on the MFU side of
the machine.
Remedy: As only single feeders can be used on an MFU, set the sub-slot to "0".
------------------------------
Code: 12061043
Display: Feeder ID reader communication error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Communication is not possible due to a connection error with the Feeder ID 2D code reader.
Remedy: Ensure that the communication cable is properly connected, and that the connection port
number has been specified correctly at the [Parts Administration System] setting screen.
------------------------------
Code: 12061044
Display: Station 1 pickup stopper error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The nozzle is at the lowered position even though the station 1 pickup stopper is engaged.
Remedy: Check the operation of the station 1 stopper at output port Y030.
------------------------------
Code: 12061045
Display: Station 9 pickup stopper error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The nozzle is at the lowered position even though the station 9 pickup stopper is
engaged.Exercise caution as double pl
acement may occur if parts are being held on the nozzles at station 9.
Remedy: Check the operation of the station 1 stopper at output port Y034.
------------------------------
Code: 12061046
Display: Feeder ID reader setting receipt error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: An error occurred while downloading the Feeder ID settings data.
Remedy: Ensure that the communication cable is properly connected.
------------------------------
Code: 12061047
Display: Parts reject error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The error part was not properly rejected.
Remedy: If the part is still being held by the nozzle at station 9, it should be removed. Adjust the station
13 "kiss-off" valve and the brush on the parts reject tray.
------------------------------
Code: 12061049
Display: Tape cutter not working properly.
Used by: CP-732E, CP-742ME, CP-742E, CP-733E, CP-743ME, CP-743E
Cause: The vertical motion of the tape cutter lever is not smooth.
The mechanical valve on the nozzle shaft may be contacting the pusher on the Station 13 valve switching
lever, which is linked to the tape cutter.
Remedy: Adjust and lubricate the tape cutter lever and Station 13 valve pusher lever assemblies.
------------------------------
第 605 页
Code: 1206104A
Display: NY-axis start processing error
Used by: CP-8Series
Cause: An NY-axis start signal was output while in error status.
Remedy: Correct the cause of the error, and push READY ON.
------------------------------
Code: 1206104C
Display: Outside target position movement range
Used by: CP-8Series
Cause: The target destination of the NY-axis exceeds the plus limit in calibration data.
Remedy: Adjust the NY-axis.
------------------------------
Code: 1206104D
Display: Outside target position movement range
Used by: CP-8Series
Cause: The target destination of the NY-axis exceeds the minus limit in calibration data.
Remedy: Adjust the NY-axis.
------------------------------
Code: 12061050
Display: FQ offset amount error
Used by: CP-732E, CP-742ME, CP-742E, CP-733E, CP-743ME, CP-743E
Cause: The FQ rotation cannot be performed within the permissible cycle time as the Q-direction vision
processing offset amount is too large.
Remedy: Please check the pick-up status of the part.As a preliminary measure, set a value of "20" for the
"Pickup Tolerance" item in part data.
------------------------------
Code: 12061052
Display: A signal was received from Fujitrax Verifier stating that feeder verification was not possible.
Check the feeder for which the LED is illuminated.
Used by: CP43,CP6,CP6M,CP65,CP642,CP642M,CP643,CP643M
Cause: A signal was received from Fujitrax Verifier stating that feeder verification was not possible.
Check the feeder for which the LED is illuminated.
Remedy: Check the error details at the Fujitrax computer and take necessary measures.
------------------------------
Code: 12061053
Display: Nozzle center unmeasured
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: Nozzle holder center measurement has not been performed for the holder displayed in the
parameter section after performing part camera calibration data measurement or (X0,Y0) calibration data
measurement. There is a possibility of a drop in accuracy.
Remedy: Attach a 1.0~2.5mm nozzle and perform nozzle holder center measurement.
------------------------------
Code: 12061054
Display: Maintenance key is OFF
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: The Maintenance Mode cannot be used because the maintenance key is switched OFF.
Remedy: Switch the maintenance key ON, or exit from the Maintenance Mode panel and push the READY
ON button.
------------------------------
Code: 12061055
Display: Maintenance Mode unavailable
第 606 页
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: The maintenance key was turned ON, but the Maintenance Mode panel is not open so the
Maintenance Mode cannot be activated.
Remedy: Open the Maintenance Mode panel, or switch the maintenance mode key OFF and push the
READY ON button.
------------------------------
Code: 12062001
Display: ERROR CV parts Full
Used by: IP1,IP2
Cause: The rejected parts conveyor belts has too many parts on it, the sensor is on, and more parts
cannot be rejected.
Remedy: Remove the parts from the conveyor (IP). Also, adjust the sensor position and sensitivity.
------------------------------
Code: 12062002
Display: RESCAN ERROR
Used by: IP1,IP2
Cause: Rescanning was done 3 times but the part was still not at the angle specified in Part data.
Remedy: Check the part supply, and check Part data.
------------------------------
Code: 12062003
Display: Sub Nozzle
Used by: IP1
Cause: The sub-nozzle moved down while the sub-robot was in motion (IP).
Remedy: Check the air pressure and the sub-nozzle's raised position.
------------------------------
Code: 12062004
Display: Please use new NOZZLE CHANGE
Used by:
Cause: This occurs on versions using v2.30 and later ROM chips during nozzle change (IP). Nozzle
change on these versions are not supported.
Remedy: Use the new type. Refer to the "Appendix, Part 1.2" 69 : Machine Status B of the IP manual.
------------------------------
Code: 12062005
Display: Error L(R) Tray original
Used by: IP1
Cause: The I/O setting RT_READY/LT_READY is off(IP, IP2).
Remedy: Inch the tray to the sensor where the sensor should be on and check the I/O display.
Alternately, with the servo lock cancelled, and the SX zero setting dog sensor and SX Interference check
dog sensor on, press [UNIT] and [D] to return to the original position. Note that when the dog has been
removed, and the tray is down below the point where it would be after zero setting, do not use the [D]
command key.
------------------------------
Code: 12062006
Display: Error: Sub Robot original
Used by: IP1
Cause: The sub-robot is not in its original position (IP, IP2).
Remedy: Inch the sub-robot to its original position. This is the position where the SX zero setting dog
sensor and SX Interference check dog sensor are on.
------------------------------
Code: 12062007
Display: L(R) TRAY SET ERROR