Code: 1202020C Display: Used by: IP2,IP3 Cause: There was a TPU communication alarm. Remedy: Check the I/O board at the machine. ------------------------------ Code: 1202020D Display: Used by: IP2,IP3 Cause: The TPU is o…

100%1 / 5282
Remedy: Execute the recovery command.
------------------------------
Code: 12020204
Display: TPU SHUTTLE ERROR
Used by: IP2,IP3
Cause: The shuttle does not work properly.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020205
Display: TPU FORMING ERROR
Used by: IP2,IP3
Cause: The cut-and-form mechanism does not work properly.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020206
Display: TPU SUPPLY ERROR
Used by: IP2,IP3
Cause: The TPU part supplier does not work properly.
Remedy: Operate the equipment in manual operation. Also, check the supplier at the I/O board.
------------------------------
Code: 12020207
Display: TPU ORIGINAL POSITION ERROR
Used by: IP2,IP3
Cause: When the TPU was started, the shuttle or the cut-and-form mechanism was not in the original
position.
Remedy: Return these parts to the origin position in manual operation.
------------------------------
Code: 12020208
Display: TPU MANUAL MODE ERROR
Used by: IP2,IP3
Cause: The TPU is in manual operation.
Remedy: Perform production in automatic operation.
------------------------------
Code: 12020209
Display: TPU EMERGENCY
Used by: IP2,IP3
Cause: The TPU has been subject to an emergency stop.
Remedy: Release the Emergency Stop button, or check for the cause at the I/O board.
------------------------------
Code: 1202020A
Display:
Used by: IP2,IP3
Cause: A parameter was specified incorrectly during startup of the TPU.
Remedy: Check the production program.
------------------------------
Code: 1202020B
Display:
Used by: IP3
Cause: A part supply cycle could not be completed.
Remedy: Check the I/O board at the machine.
------------------------------
第 291 页
Code: 1202020C
Display:
Used by: IP2,IP3
Cause: There was a TPU communication alarm.
Remedy: Check the I/O board at the machine.
------------------------------
Code: 1202020D
Display:
Used by: IP2,IP3
Cause: The TPU is out of parts.
Remedy: Supply parts to the TPU. Check the part sensors at the input section of the I/O board.
------------------------------
Code: 1202020E
Display:
Used by: IP2,IP3
Cause: There was a TPU communication alarm.
Remedy: Check the I/O board at the machine.
------------------------------
Code: 12020300
Display:
Used by: GSP5
Cause: An alarm was issued from the solder supplier.
Remedy: This is probably a solder supplier amp error. Check the solder supplier manual for more details.
------------------------------
Code: 12020301
Display:
Used by: GSP5
Cause: Too much amperage (0.7 amps or over) was flowing through the motor.
Remedy: The outer tubing is loose or the spiral shaft is not set in the garage. Check these items.
------------------------------
Code: 12020302
Display:
Used by: GSP5
Cause: Not enough amperage is flowing through the motor.
Remedy: The spiral shaft is removed or the motor is not rotating. Check these items.
------------------------------
Code: 12020303
Display:
Used by: GSP5
Cause: The cylinder takes too long (10 seconds or longer) to return.
Remedy: The air pressure is too low, the piston section has a load on it, or the upper limit confirmation
sensor (in the upper part of the cylinder section) has slipped. Check each of these items and make
adjustments.
------------------------------
Code: 12020305
Display:
Used by: GSP5
Cause: The solder outflow setting is out of range.
Remedy: Specify 8.0 cm3/s or less.
------------------------------
Code: 12020306
第 292 页
Display:
Used by: GSP5
Cause: The viscosity setting is out of range.
Remedy: Check solder_viscsty in the production program. The range is 1 to 60 [*10 Pa.s].
------------------------------
Code: 12020307
Display:
Used by: GSP5
Cause: Even after mixing was done for a certain time (1 hour 30 minutes) the viscosity did not go below
the viscosity specified.
Remedy: The viscosity specification is probably too high. Chenge the setting.
------------------------------
Code: 12020308
Display:
Used by: GSP5
Cause: There is no solder.
Remedy: Add solder. If this error occurs even if there is solder left, this means that the viscosity level is
too high, the solder was just transferred from the fridge or you are using high-viscosity (2500P) solder.
Check each of these points and make appropriate adjustments.
------------------------------
Code: 12020309
Display:
Used by: GSP5
Cause: The garage has not been set in the housing.
Remedy: The housing has been removed, or the sensor is not working properly. Check these points and
make adjustments.
------------------------------
Code: 12020320
Display:
Used by: GSP5
Cause: Communication was not possible with the solder supply machine.
Remedy: Check that the solder supply machine is turned on, and that the communication cable is
correctly connected.
------------------------------
Code: 12020401
Display:
Used by:
Cause: The elevator could not ascend or descend in the specified time.
Remedy: Check the load on the stocker elevator being raised or lowered.
------------------------------
Code: 12020402
Display:
Used by:
Cause: The stocker could not be clamped within the specified time.
Remedy: Check that the stocker is set in the correct position. Check that the stocker clamp cylinder is
moving properly.
------------------------------
Code: 12020403
Display:
Used by:
Cause: The Y transport could not advance or retract in the specified time.
第 293 页