FUJI错误代码查询.pdf - 第2141页
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence setting, does not exist. Remedy: The program file is incorrect. Check and correct the file contents. -------------------…
Used by:
Cause: The tray dimensions are outside the permissible XP tray specifications (4.00mm - 25.40mm).
Remedy: Remedy: Input a permissible tray thickness (4.00mm - 25.40mm).
------------------------------
Code: 2300E5DB
Display: Set [Tray Length] to 95.00 mm or more when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays if the "Tray Length" setting is less than 95.00
mm.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Length" to 95.00 mm or more.
------------------------------
Code: 2300E5DC
Display: Set [Tray Width] to 95.00 mm or more when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays if the "Tray Width" setting is less than 95.00
mm.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Width" to 95.00 mm or more.
------------------------------
Code: 2300E5DD
Display: The current [Tray Dump Pick Position X] setting is incorrect when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays with the specified "Tray Dump Pick Position X"
setting.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Dump Pick Position X" so that the remover picks up
the tray at the correct position.
(Use the following formula to set the correct value.)
95 / 2 =< [Tray Dump Pick Position X] x (-1) =< [Tray Length] - (95 / 2)
------------------------------
Code: 2300E5DE
Display: The current [Tray Dump Pick Position Y] setting is incorrect when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays with the specified "Tray Dump Pick Position Y"
setting.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Dump Pick Position Y" so that the remover picks up
the tray at the correct position.
(Use the following formula to set the correct value.)
95 / 2 =< [Tray Dump Pick Position Y] =< [Tray Width] - (95 / 2)
------------------------------
Code: 23040005
Display: A feeder does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23040006
Display: Part data referred to by the sequence slot does not exist.
Used by:
第 2140 页
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence
setting, does not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23040008
Display: No feeder exists in the slot referenced by this skipped sequence (for skipped sequences included
in optimization).
Used by:
Cause: A feeder does not exist in a sequence slot that contains board/feeder/sequence skip settings.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2304000A
Display: Part data referred to by the skip sequence does not exist. This error can be avoided by selecting
[Lines to Skip are Removed] when you optimize.
Used by:
Cause: The part data referred to by a sequence slot containing board/feeder/sequence skip settings does
not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2304000D
Display: The Alt. Feeder does not exist. Do you want to set 0 for alternate feeder?
Used by:
Cause: A feeder is not set in the alternate feeder specified for the displayed stage-slot.
Remedy: The Feeder Setup information in the program file is incorrect. Check the settings.
------------------------------
Code: 2304000E
Display: There are too many feeders allocated to one stage.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of feeders allocated to the stage exceeded the maximum feeder slots.
Remedy: Firstly, try changing the [Use feeder type] settings. If unsuccessful, perform optimization using
the [Alt. Feeders are Removed] setting. If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 23040010
Display: Part data referred to by the unused feeders in the [Fix Feeder Slots] does not exist. (Even for
unused feeder(s) without part data, it can't be determined whether the feeder is set at the machine.) This
error can be avoided by selecting [Automatic Most Suitable Feeder Arrangement] when you optimize.
Used by:
Cause: There is no part data displayed in the Feeder Setup.
Remedy: The program file data is incorrect. Check the contents.
------------------------------
Code: 23040012
Display: The slot number does not exist at the machine. This error can be avoided by selecting [Automatic
Most Suitable Feeder Arrangement] when you optimize.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23040015
第 2141 页
Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close
to the feeder to the left.
Used by:
Cause: In the program's feeder setup, a feeder wide enough to interfere with the adjacent feeder on the
left side.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 2304001A
Display: Are you finished?
Used by:
Cause: The confirmation dialog displays at each time of completion.
Remedy: Select [Yes] to finish. Select [No] to continue.
------------------------------
Code: 2304001B
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, or optimization process has completed, but the optimized
program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
When attempting to open the program file, select [No] to abandon the optimized program, and display the
dialog for selecting a new program file to be optimized.
When optimization process has completed, select [No] to exit without saving the optimized program.
------------------------------
Code: 2304001C
Display: No nozzle is registered.
Used by:
Cause: No valid nozzle match could be made between the Nozzle Config. file's NCFTYPE and the Nozzle
Spec. file's NSPNAME.
Remedy: There is a problem with either or both files. Normally, the Nozzle Config. and Nozzle Spec. files
in the MCS-X default directory are read automatically. Check that both files contain correct data. When
starting up the optimizer, in cases where prompted to specify a file because the default file cannot be
found, check the file contents and correct if necessary.
------------------------------
Code: 2304001D
Display: Nozzle Configuration File "Fujinzl.cfg" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 2304001E
Display: The contents of Nozzle Configuration File are empty.
Used by:
Cause: The Nozzle Config. file is empty.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------