[Air Cylinder Cycle Alarm Push Plate] Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,GPX,GPX-C Cause: 电路板压板在时间内没有能够按指示动作。 Remedy: 请确认是否存在妨害电路板压板动作的东西。 <img src="$LKEY_ERRIMG_MC$/EI0010.bmp"> ------------------…
Display: Cycle Alarm Chuck
Used by: IP1,IP2
Cause: There was a nozzle chuck cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the nozzle chuck cylinder.
------------------------------
Code: 12054018
Display: Cycle Alarm H2
Used by: IP2
Cause: A time up error has occured for the cylinder which moves the second holder to its ready position.
Remedy: Check the cylinder.
------------------------------
Code: 12054019
Display: Cycle Alarm H3
Used by: IP2
Cause: A time up error has occured for the cylinder which moves the third holder to its ready position.
Remedy: Check the cylinder.
------------------------------
Code: 1205401A
Display: Cycle Alarm ESC 2
Used by: IP2
Cause: A time up error has occured for the cylinder which moves the first holder to its retracted position.
Remedy: Check the cylinder.
------------------------------
Code: 1205401B
Display: Cycle Alarm ESC 3
Used by: IP2
Cause: A time up error has occured for the cylinder which moves the second holder to its retracted
position.
Remedy: Check the cylinder.
------------------------------
Code: 1205401D
Display: Cycle Alarm MFU1 Notch
Used by: IP2
Cause: The MFU1 fixed notch did not go in within the preset time.
Remedy: Check that the MFU1 fixed notch cylinder is operating properly.
------------------------------
Code: 1205401E
Display: Cycle Alarm MFU2 Notch
Used by: IP2
Cause: The MFU2 fixed notch did not go in within the preset time.
Remedy: Check that the MFU2 fixed notch cylinder is operating properly.
------------------------------
Code: 1205401F
Display: Cycle Alarm FRAME
Used by: GSP2,GSP3,GP2,GP3
Cause: The frame did not operate properly within the preset time.
Remedy: Check that there is no object interfering with the movement of the frame.
------------------------------
Code: 12054020
Display: 周期异常 电路板压板 L or R (GSP)
周期异常 汽缸 电路板压板(GP)
第 545 页
[Air Cylinder Cycle Alarm Push Plate]
Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,GPX,GPX-C
Cause: 电路板压板在时间内没有能够按指示动作。
Remedy: 请确认是否存在妨害电路板压板动作的东西。
<img src="$LKEY_ERRIMG_MC$/EI0010.bmp">
------------------------------
Code: 12054022
Display: Cycle Alarm Squeegee R
Used by: GSP2,GSP3,GP2,GP3
Cause: The right squeegee did not lower or raise itself in the preset time.
Remedy: Check that there is nothing interfering with the movement of the right squeegee.
------------------------------
Code: 12054023
Display: Cycle Alarm Squeegee L
Used by: GSP2,GSP3,GP2,GP3
Cause: the left squeegee did not lower or raise itself in the preset time.
Remedy: Check that there is nothing interfering with the movement of the left squeegee.
------------------------------
Code: 12054024
Display: "Cycle alarm: notch alarm" (GSP)
Used by: GSP2,GSP3,GP2,GP3
Cause: Notch insertion or removal is incomplete.
Remedy: Check notch insertion and removal, and adjust the following sensors:
IN2-31 L_PLT.NOTCH_OUT, IN2-30 R_PLT.NOTCH_OUT, IN3-13
R_PLT_.NOTCH_IN, and IN3-12 L_PLT.NOTCH_IN.
------------------------------
Code: 12054025
Display: "Cycle alarm: notch" (GSP)
Used by: GSP2,GSP3,GP2,GP3
Cause: Notch insertion or removal is incomplete.
Remedy: Check notch insertion and removal, and adjust the following sensors:
IN2-31 L_PLT.NOTCH_OUT, IN2-30 R_PLT.NOTCH_OUT, IN3-13
R_PLT_.NOTCH_IN, and IN3-12 L_PLT.NOTCH_IN.
------------------------------
Code: 12054026
Display: "Cycle alarm: SCR_F_Catch" (GSP)
Used by: GSP2,GSP3
Cause: The automatic screen replacement front screen catch could not be opened in the specified time.
Remedy: Make sure that nothing is obstructing the operation of the automatic screen replacement front
screen catch.
------------------------------
Code: 12054027
Display: "Cycle alarm: SCR_Guide" (GSP)
Used by: GSP2,GSP3
Cause: The automatic screen replacement rear screen guide could not be opened in the specified time.
Remedy: Make sure that nothing is obstructing the operation of the automatic screen replacement rear
screen guide .
------------------------------
Code: 12054028
Display: "Cycle alarm: SCR_Clamper" (GSP)
Used by: GSP2,GSP3
第 546 页
Cause: The automatic screen replacement rear screen clamper could not be opened in the specified time.
Remedy: Make sure that nothing is obstructing the operation of the automatic screen replacement rear
screen clamper .
------------------------------
Code: 12054029
Display: "Cycle alarm: Check SCR" (GSP)
Used by: GSP2,GSP3
Cause: One of the following conditions occurred during screen replacement: the screen was not securely
clamped, the frame positioning sensor has not turned on (because the sensor is not in the properposition),
or the frame pressure check sensor has not turned on (for the same reason).
Remedy: Check the position of the screen, and make sure that it is securely clamped. Check the sensor
positions.
------------------------------
Code: 1205402A
Display: "Cycle alarm: Stocker" (GSP)
Used by: GSP2,GSP3
Cause: The stocker did not arrive at the upper or lower limit within the expected time.
Remedy: Make sure that nothing is obstructing the stocker's vertical movement. Inspect the machine.
------------------------------
Code: 1205402B
Display: "Cycle alarm: side clamp" (GSP)
Used by: GSP2,GSP3,GSP5,GP551,GP6,NXTP
Cause: An instruction was issued to open or close the side clamp, but the side clamp couldn't be opened
or closed within a 1-second period.
Remedy: Use the loader clamp command to clamp a board, then use an I/O command to make sure that
the input from sensor 1-29 PCB_SIDE_UNCLAMP is functioning normally.If the sensor does not respond
properly, adjust the sensor position. Otherwise, raise the "clamp_press" setting in the production
program.
<img src="$LKEY_ERRIMG_MC$/1205402B.PNG">
------------------------------
Code: 1205402C
Display:
Used by: CP4-1,CP4-2,CP4-3,IP3
Cause: The nozzle change cylinder could not retract within the specified time limit.
Remedy: Use the I/O board to check that the cylinder can advance and retract.Check that the appropriate
sensors turn on and off at the advance and retract limit positions.
------------------------------
Code: 1205402D
Display:
Used by: IP3
Cause: The reflow head could not finish rotating within the specified time limit.
Remedy: Check that the reflow head rotates smoothly, using the output section of the I/O board. Check
that the head is ON at 0 deg. and 90 deg..
------------------------------
Code: 1205402E
Display:
Used by: IP3
Cause: The reflow nozzle could not raise or lower itself within the specified time limit.
Remedy: Check that the reflow nozzle raises and lowers smoothly, using the output section of the I/O
board. Check that the sensors are on at the upper and lower limit positions.
------------------------------