FUJI错误代码查询.pdf - 第2138页

Check the Element settings. Change the Vision Type. ------------------------------ Code: 2300E5B0 Display: [Packaging Type]-[Feed Count] is not defined. Used by: Cause: A [Packaging Type]-[Feed Count] setting of "0&…

100%1 / 5282
Remedy: Specify 2 or more lines for the "Element"setting.
------------------------------
Code: 2300E589
Display: 2 or more Element lines are required for Vision Type 124.
Used by:
Cause: For Vision Type 124,vision processing is only possible when the "Element"setting occupies 2 or
more lines.
Remedy: Specify 2 or more lines for the "Element"setting.
------------------------------
Code: 2300E590
Display: The Element Result setting is Matrix for the first line for a part with Vision Type 230 or 231.
Used by:
Cause: There is an error in the element settings.The Element Result setting is Matrix for the first line for
a part with Vision Type 230 or 231.
Remedy: Change the Element Result setting to Inspect for the first line for Vision Type 230 or 231.
------------------------------
Code: 2300E591
Display: The Element Result setting is Matrix for two consecutive lines for a part with Vision Type 230 or
231.
Used by:
Cause: There is an error in the element settings.The Element Result setting is Matrix for two consecutive
lines for a part with Vision Type 230 or 231.
Remedy: Do not specify a Result setting of Matrix for consecutive lines for a part with Vision Type 230 or
231.
------------------------------
Code: 2300E592
Display: With Vision Type **,Matrix is not a compatible Result setting.
Used by:
Cause: With the specified Vision Type,the Result setting of Matrix is not compatible.
Remedy: Check the element Result setting.Check the Vision Type setting.
------------------------------
Code: 2300E593
Display: The Result setting will be treated as Inspect.
Used by:
Cause: With the specified Vision Type,the only compatible Result setting is Inspect.Processing will
continue with a Result setting of Inspect.
Remedy: Check the element Result setting.Check the Vision Type setting.
------------------------------
Code: 2300E594
Display: A Lead Quantity setting of 17 or more is not supported for Vision Type 20.
Used by:
Cause: Vision Type 20 does not allow a "Lead Quantity"setting value of 17 or higher.
Remedy: Create the part data using vision type 18 or 100.
------------------------------
Code: 2300E595
Display: For Vision Type 180,the total number of leads in [Lead Quantity]for an element whose Result
setting is Inspect must be 2,3,or 4.
Used by:
Cause: For Vision Type 180,the total number of leads in [Lead Quantity]for an element whose Result
setting is Inspect must be 2,3,or 4.
Remedy: Check the Result settings.
第 2137 页
Check the Element settings.
Change the Vision Type.
------------------------------
Code: 2300E5B0
Display: [Packaging Type]-[Feed Count] is not defined.
Used by:
Cause: A [Packaging Type]-[Feed Count] setting of "0" existed when the [Packaging Type]-[Type] setting
was other than [0:Tray], [4:Stick Feeder], [5:Grooved Stick Feeder].
Remedy: Specify a [Packaging Type]-[Feed Count] setting when the [Packaging Type]-[Type] setting is other
than [0:Tray], [4:Stick Feeder], [5:Grooved Stick Feeder].
------------------------------
Code: 2300E5B1
Display: Tape Width is not defined.
Used by:
Cause: A Packaging Data "Tape Width" setting of "0" existed when the [Packaging Type]-[Type] setting
was other than [0:Tray].
Remedy: Specify a "Tape Width" setting.
------------------------------
Code: 2300E5B2
Display: Set a value less than 4 if the Packaging Type is specified as Stick Feeder or Grooved Stick feeder.
Used by:
Cause: The stick feeder "FeedCount" is set to 4 or more.
Remedy: When using the Stick Feeder and Grooved Stick Feeder packaging types, specify a "FeedCount"
setting of 3 or less.
------------------------------
Code: 2300E5B3
Display: Make a setting at Packaging Type.
Used by:
Cause: Packaging Type is not specified in the part packaging data.
Remedy: Specify the packaging type in the Packaging edit window.
------------------------------
Code: 2300E5D0
Display: Tray Length is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but there is no "Tray Length" setting.
Remedy: When using the "Tray" packaging type, specify a "Tray Length" setting.
------------------------------
Code: 2300E5D1
Display: Tray Width is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but there is no "Tray Width" setting.
Remedy: When using the "Tray" packaging type, specify a "Tray Width" setting.
------------------------------
Code: 2300E5D2
Display: Tray Column Quantity is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but the "Tray Column Quantity" item is set to "0".
Remedy: When using the "Tray" packaging type, specify a "Tray Column Quantity" setting of 1 or higher.
------------------------------
Code: 2300E5D3
Display: Tray Row Quantity is not defined.
第 2138 页
Used by:
Cause: "Tray" is specified as the packaging type, but the "Tray Row Quantity" item is set to "0".
Remedy: When using the "Tray" packaging type, specify a "Tray Row Quantity" setting of 1 or higher.
------------------------------
Code: 2300E5D4
Display: Tray Length is not correct. Can't eject tray.
Used by:
Cause: The length of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the remover.
Remedy: Specify a "Tray Length" setting of 72 or higher.
------------------------------
Code: 2300E5D5
Display: Tray Width is not correct. Can't eject tray.
Used by:
Cause: The width of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the remover.
Remedy: Specify a "Tray Width" setting of 83 or higher.
------------------------------
Code: 2300E5D6
Display: Tray Dump Pick Position X is not correct. Can't eject tray.
Used by:
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the X-direction when
picking up a tray.
Remedy: Specify the "Tray Dump Pick Position X" setting so that the remover does not protrude beyond
the tray in the X-direction when picking up trays. (Setting value should satisfy the following equation.)
72 / 2 =< [Tray Dump Pick Position X] x (-1) =< [Tray Width] - (72 / 2)
------------------------------
Code: 2300E5D7
Display: Tray Dump Pick Position Y is not correct. Can't eject tray.
Used by:
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the Y-direction when
picking up trays.
Remedy: Specify the "Tray Dump Pick Position Y" setting so that the remover does not protrude beyond
the tray in the Y-direction when picking up trays. (Setting value should satisfy the following equation.)
83 / 2 =< [Tray Dump Pick Position Y] =< [Tray Width] - (83 / 2)
------------------------------
Code: 2300E5D8
Display: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Used by:
Cause: The final pickup position for tray parts exceeds the tray's X-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Length] => { [Tray First Pickup Position X] x (-1) } + { [Tray Column Pitch] x ( [Tray Column Quantity]
- 1) }
------------------------------
Code: 2300E5D9
Display: The pick up point for the last tray parts exceeds the tray size in the Y-direction.
Used by:
Cause: The final pickup position for tray parts exceeds the tray's Y-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Width] => [Tray First Pickup Position Y] + [Tray Row Pitch] x ( [Tray Row Quantity] - 1 )
------------------------------
Code: 2300E5DA
Display: Tray cannot be removed. Input the tray thickness (4.00mm - 25.40mm).