FUJI错误代码查询.pdf - 第163页
Used by: IP3 Cause: Conveyor Adj.Limit has no value specified even though the conveyor is being adjusted automatically. Remedy: Input an appropriate value in Proper data's 26.Conveyor Adj.Limit item. ---------------…
Normally, set this to 5 for the machine and 6 for peripherals (this is normally set when the machine is
shipped).
------------------------------
Code: 11022708
Display:
Used by:
Cause: Cell_status is set incorrectly.
Remedy: After checking Cell_status in MCS, re-transmit the Proper data.
"Unit cell" only exists on the ferris wheel feeder.
------------------------------
Code: 11022709
Display:
Used by: GP2,GP3,GP551,GP6,IP3,QP132
Cause: The Change_over_mode setting is incorrect.
Remedy: After checking the "change_over_mode" setting in MCS, re-transmit the Proper to the machine.
This is only effective when unit cell is in use. Do not use settings other than these. 0 = manual
terminate, 2 = pattern code reader, 4 = upper surface barcode reader, 5 = lower surface barcode reader
and 25 = barcode reader for both surfaces. For the Board Stacker, use 0 (manual terminate). For the
Ferris Wheel Feeder, use 4 (upper surface barcode reader).
------------------------------
Code: 1102270A
Display:
Used by: IP3,QP132
Cause: Command_line_status is set incorrectly.
Remedy: After checking the Command_line_status in MCS, re-transmit the Proper to the machine. LAN is
not currently recommended.
------------------------------
Code: 1102270B
Display:
Used by:
Cause: Terminal_type is set incorrectly.
Remedy: After checking the Terminal_type in MCS, re-transmit the Proper to machine. With Cell_status
at Unit, Change_over_mode at 2, 4, 5 or 25, and PCB_code_terminal at Use, this must be set. Choose
"CRX1200" or "HT." "VT-100" is not compatible.
------------------------------
Code: 1102270C
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The Device Check Port, Command Line Port, Reader1 Port No., Reader2 Port No., Code Terminal
Port Proper data settings are set to the same number.
Remedy: Check the Device Check Port, Command Line Port, Reader1 Port No., Reader2 Port No., Code
Terminal Port Proper data settings in MCS, re-transmit the Proper data to the machine. Check the Device
Check Port, which must be set when using the Handy Terminal. Normally this is set to 1.
1 is the first connector from the top of the first communication board. This is normally set when the
machine is shipped. Command Line Port 2 is normally set to 2. Reader1 Port No. or Reader2 Port No. are
connected with the Pattern code reader, or the lower surface code reader. These are normally set to 3 and
4. Code Terminal Port is connected when the recovery terminal (code input) is used. This is normally set
to 5. 5 is the first connector from the top of the 2nd communication board.
------------------------------
Code: 1102270D
Display:
第 162 页
Used by: IP3
Cause: Conveyor Adj.Limit has no value specified even though the conveyor is being adjusted
automatically.
Remedy: Input an appropriate value in Proper data's 26.Conveyor Adj.Limit item.
------------------------------
Code: 1102270E
Display:
Used by: IP3
Cause: Conveyor Stop_offset has no value specified even though the conveyor is being adjusted
automatically.
Remedy: Input an appropriate value in Proper data's 27.Conveyor Stop_offset item.
------------------------------
Code: 1102270F
Display:
Used by: IP3
Cause: The value input in Conveyor Adj.Limit is smaller than the value input in Conveyor Stop_offset.
Remedy: Input a value in 26.Conveyor Adj.Limit which is larger than the value in 27.Conveyor
Stop_offset.
------------------------------
Code: 11022710
Display:
Used by: IP3
Cause: Conveyor adj. Timer has no value specified even though the conveyor is being adjusted
automatically.
Remedy: Input an appropriate value in Proper data's 28.Conveyor adj. Timer item.
------------------------------
Code: 11022711
Display:
Used by: IP3
Cause: Width Max Limit has no value specified.
Remedy: Input an appropriate value in Proper data's 29.Width Max Limit item.
------------------------------
Code: 11022712
Display:
Used by: IP3
Cause: Width Min Limit has no value specified.
Remedy: Input an appropriate value in Proper data's 30.Width Min Limit item.
------------------------------
Code: 11022713
Display:
Used by: IP3
Cause: The value input in Width Max Limit is smaller than the value input in Width Min Limit.
Remedy: Input a value in 29.Width Max Limit which is larger than the value in 30.Width Min Limit.
------------------------------
Code: 11022714
Display:
Used by: IP3,QP132
Cause: Terminal Type has no value specified.
Remedy: Input an appropriate value in Proper data's 56.Terminal Type item.
------------------------------
Code: 11022715
第 163 页
Display: 11022715
Used by:
Cause: During HELPS operation, the Reader_type in Proper data is set to a value other than 0 when the
board type report for LMS is manual terminate.
Remedy: Retransmit Proper data after setting Reader_type in Proper data to 0.
------------------------------
Code: 11022716
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP642M,CP643,CP643M
Cause: A value other than "30" has been specified at Proper data item "change_over_mode", even though
Proper data item "reader_type is set to "4". Or, a value other than "4" has been specified at Proper data
item "reader_type", even though Proper data item "change_over_mode" is set to "30".
Remedy: Check Proper data items "reader_type" and "change_over_mode".
------------------------------
Code: 11022800
Display:
Used by:
Cause: When Proper data was checked, there was no Proper for the peripgerals.
Remedy: Transmit the Proper data for the peripherals.
------------------------------
Code: 11022801
Display:
Used by:
Cause: Machine_type is set incorrectly.
Remedy: After checking the Machine_type setting in MCS, re-transmit the Proper data to the machine.
1 = flip station.
2 = input terminal.
3 = output terminal.
4 = intermediate buffer.
5 = board stacker.
7 = MBID.
8 = ferris wheel feeder.
------------------------------
Code: 11022802
Display:
Used by:
Cause: Machine_control_port is set incorrectly.
Remedy: After checking the Machine_control_port setting, re-transmit the Proper to the machine. When
machine_control_mode is set at 2~5, a setting must be made for MBID. This setting connects the next
production stage and the RS-232C cable to the LCU connector (connector number 1~8).
Do not use the settings 1, 3 or those chosen for Command_line_port, Reader1_port, Reader2_port or
Code_terminal_port. Normally setting 7 is used. This is set when the machine is shipped.
------------------------------
Code: 11022803
Display:
Used by:
Cause: Machine_control_mode is set incorrectly.
Remedy: After checking Machine_control_mode in MCS, re-transmit the Proper data.
0 = outside MBID.
1 = working display.
2 = Research MP-4470 Reflow oven.
第 164 页