Used by: Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error occurred when the feeder width was checked against the end of the station. Remedy: Change the PST specific…

100%1 / 5282
Code: 21007946
Display: No entry Machine name.
Used by:
Cause: The machine name is not registered in Part data.
Remedy: Using the editor input the machine name in Part data.
------------------------------
Code: 21007947
Display: Illegal format at pairing data file.
Used by:
Cause: The pairing data file format is unsuitable.
Remedy: Re-install the pairing data file.
------------------------------
Code: 21007948
Display: Not get queue position.
Used by:
Cause: The queue position cannot be obtained.
Remedy: Reboot the MCS.
------------------------------
Code: 21007949
Display: Sequence data axis over range.
Used by:
Cause: The sequence coordinates exceed the board size.
Remedy: Edit the input program to ensure that the sequence data coordinates (X, Y) do not exceed the
board size.
------------------------------
Code: 2100794A
Display: Cam table file open error.
Used by:
Cause: The cam table file cannot be opened.
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794B
Display: Cam table file read error.
Used by:
Cause: The cam table file cannot be read.
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794C
Display: Tllegal format at Cam table file.
Used by:
Cause: The cam table file format is unsuitable
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794D
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100794E
Display: "There is insufficient space for a feeder in PT file"
第 1983 页
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 2100794F
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21008001
Display: Command Format Error: makenet [-e] +wtlb
Used by:
Cause: An incorrect option is being used.
Remedy: Check the start-up option.
------------------------------
Code: 21008002
Display: Message not found!! No.= ****
Used by:
Cause: Unable to find the necessary message file.
Remedy: Re-install MCS/2E system.
------------------------------
Code: 21008010
Display: Edit file Open error !!
Used by:
Cause: The file created by the editor could not open ethernet_db.
Remedy: Create ethernet_db with the editor.
------------------------------
Code: 21008014
Display: Data base file Open error !!
Used by:
Cause: Unable to open data base files such as hosts, services, etc.
Remedy: Input ':' at the UCI menu and execute "/h0/cmds/attr -w /h0/etc/*" to enable the files to be
read.
------------------------------
Code: 21008020
Display: IP_ADDRESS not digit data !! "disit.digit.digit.digit"
Used by:
Cause: The IP address is incorrect.
Remedy: The IP address must be made up entirely of numerical digits.
------------------------------
Code: 21008021
Display: IP_ADDRESS data rimit over or nothing !! "123.123.123.123"
Used by:
Cause: The IP address is incorrect.
Remedy: Each address group must be between 1 and 3 digits.
------------------------------
Code: 21008022
Display: IP_ADDRESS not 4 data !! "1.2.3.4"
第 1984 页
Used by:
Cause: The IP address is incorrect.
Remedy: The four groups of data must be punctuated by a period (.).
------------------------------
Code: 21008023
Display: IP_ADDRESS rimit error !! [0 - 255]
Used by:
Cause: The IP address is incorrect.
Remedy: The address value must be between 0 and 255.
------------------------------
Code: 21008030
Display: REMOTEENT is nothing !! Please input REMOTEENT data.
Used by:
Cause: There is no remote host.
Remedy: Always set the remote host when using MCS/E installer.
------------------------------
Code: 21008040
Display: Data module make error !! E_code = ****
Used by:
Cause: Unable to create the "anetdb" data module.
Remedy: Re-install MCS/2E system.
------------------------------
Code: 21008041
Display: Data module fork error !!
Used by:
Cause: The process by which the "anetdb" data module is created cannot be started up.
Remedy: MCS/2E Re-install MCS/2E system.
------------------------------
Code: 21008042
Display: Unlink error !! <anetdb>
Used by:
Cause: The "anetdb" data module cannot be unlinked.
Remedy: Re-boot MCS/2E system
------------------------------
Code: 21008043
Display: Change directory error !! E_code = ****
Used by:
Cause: Unable to perform a directory change.
Remedy: The MCS/2E system directory cannot be created so re-install MCS/2E system.
------------------------------
Code: 21008050
Display: Message file open error !!
Used by:
Cause: Unable to open the message file directory.
Remedy: Re-install MCS/2E system.
------------------------------
Code: 21008051
Display: Message file data not found !!
Used by:
Cause: The target data is not in the message file.
Remedy: Re-install MCS/2E system.