data. ------------------------------ Code: 1D1AC7?? Display: Used by: Cause: An edge could not be detected on the upper side of the part. Remedy: Check the part. Check the direction of part supply. Check the entries in P…
------------------------------
Code: 1D1AC0??
Display:
Used by:
Cause: A lead could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AC1??
Display:
Used by:
Cause: A lead could not be detected on the lower side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AC2??
Display:
Used by:
Cause: A lead could not be detected on the right side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AC3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AC4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AC5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AC6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
第 1511 页
data.
------------------------------
Code: 1D1AC7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AD000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D1AD080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D1AE???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1AF???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D1D0001
Display: Same as code.
Used by:
Cause: There is an omission in the Part data.
Remedy: Enter the necessary data.
------------------------------
Code: 1D1D0002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is too large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D1D0003
Display: Same as code.
Used by:
第 1512 页
Cause: The camera cannot acquire a part image. The part is too large.
Remedy: Check the camera, video processing board, cable, and focus. Check the part. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D1D0004
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Inspect the part for missing leads, and check lead width. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D1D0005
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D0006
Display: Same as code.
Used by:
Cause: Only one lead could be found.
Remedy: Inspect the part for missing leads, and check the part supply direction. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D1D0007
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D0008
Display: Same as code.
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D0009
Display: Same as code.
Used by:
第 1513 页