FUJI错误代码查询.pdf - 第86页

Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table (devices 168~181 on the CP5). Remedy: Check the appropriate devices for the correct size, alter the Part data or the no…

100%1 / 5282
Code: 1101D006
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 79~91 on the CP4 and 84~97 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D007
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 92~104 on the CP4 and 98~111 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D008
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 105~117 on the CP4 and 112~125 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D009
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 118~130 on the CP4 and 126~139 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D00A
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 131~140 on the CP4 and 140~153 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D00B
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 154~167 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D00C
Display:
Used by: CP5
第 85 页
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 168~181 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D00D
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 182~195 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D00E
Display:
Used by: CP5
Cause: The nozzles set in Part data in the production program are not in the nozzle allocation table
(devices 196~209 on the CP5).
Remedy: Check the appropriate devices for the correct size, alter the Part data or the nozzle allocation
table, and transmit the program.
------------------------------
Code: 1101D010
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 1~13 on the CP4 and CP5) is set to 0 (zero). On the CP5, this error occurs only on versions
t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D011
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 14~26 on the CP4 or 14~27 on the CP5) is set to 0 (zero). On the CP5, this error occurs only
on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D012
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 27~39 on the CP4 or 28~41 on the CP5) is set to 0 (zero). On the CP5, this error occurs only
on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D013
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 40~52 on the CP4 and 42~55 on the CP5) is set to 0 (zero). On the CP5, this error occurs
only on versions t1.0M or later.
第 86 页
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D014
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 53~65 on the CP4 and 56~69 on the CP5) is set to 0 (zero). On the CP5, this error occurs
only on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D015
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 66~78 on the CP4 and 70~83 on the CP5) is set to 0 (zero). On the CP5, this error occurs
only on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D016
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 79~91 on the CP4 and 84~97 on the CP5) is set to 0 (zero). On the CP5, this error occurs
only on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D017
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 92~104 on the CP4 and 98~111 on the CP5) is set to 0 (zero). On the CP5, this error occurs
only on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D018
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 105~117 on the CP4 and 112~125 on the CP5) is set to 0 (zero). On the CP5, this error
occurs only on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D019
Display:
Used by: CP5
Cause: The "Index_Speed_CP5" setting or the "Cam_Speed_CP4" setting in Part data for the device being
used (devices 118~130 on the CP4 and 126~139 on the CP5) is set to 0 (zero). On the CP5, this error
occurs only on versions t1.0M or later.
Remedy: Set a suitable value for the device and re-transmit the program.
------------------------------
Code: 1101D01A
第 87 页