FUJI错误代码查询.pdf - 第2177页
Remedy: Stop importing images and perform composition. ------------------------------ Code: 230A0010 Display: No images for composition. Used by: PDW Cause: An error occurred during composition. Remedy: Import images tha…
Display: Please enter an integer between A and B.
Used by: PDW
Cause: A value outside the acceptable range was input.
Remedy: Input an integer between A and B.
------------------------------
Code: 230A0008
Display: Please enter a number between A and B.
Used by: PDW
Cause: A value outside the acceptable range was input.
Remedy: Input a number between A and B.
------------------------------
Code: 230A0009
Display: Please enter no more than A characters.
Used by: PDW
Cause: Too many characters input.
Remedy: Reduce the number of characters.
------------------------------
Code: 230A000A
Display: Please enter an integer between 0 and 255.
Used by: PDW
Cause: A value outside the acceptable range was input.
Remedy: Input an integer between 0 and 255.
------------------------------
Code: 230A000B
Display: Please enter a positive integer.
Used by: PDW
Cause: A negative decimal value was input.
Remedy: Input a positive integer.
------------------------------
Code: 230A000C
Display: Out of memory.
Used by: PDW
Cause: There is insufficient internal memory remaining.
Remedy: Reboot the PC.
------------------------------
Code: 230A000D
Display: Failed to import the image(s).
Used by: PDW
Cause: Failed to import the image(s).
Remedy: Position the mark within the search area.
------------------------------
Code: 230A000E
Display: Composition failed.
Used by: PDW
Cause: Composition of the imported image failed.
Remedy: None
------------------------------
Code: 230A000F
Display: No more can be imported.
Used by: PDW
Cause: The maximum number of images has been exceeded.
第 2176 页
Remedy: Stop importing images and perform composition.
------------------------------
Code: 230A0010
Display: No images for composition.
Used by: PDW
Cause: An error occurred during composition.
Remedy: Import images that can be composed.
------------------------------
Code: 230A0011
Display: Multiframe acquisitions cannot be carried out on fields of view where X = 50 mm or less.
Used by: PDW
Cause: The field of view is too narrow.
Remedy: Change the field of view and perform calibration.
------------------------------
Code: 230A0012
Display: No part data file.\nClosing PDW.
Used by: PDW
Cause: PDW cannot be started because the specified PDS file does not exist.
Remedy: Correct the PDS file specification and retry.
------------------------------
Code: 230A0013
Display: Part Data Wizard V1.10 cannot be used with Vision Type %d.\nClosing PDW.
Used by: PDW
Cause: PDW cannot be started because the specified vision type is not supported.
Remedy: Change the PTPVICVT value in the PDS file.
------------------------------
Code: 230A2001
Display: Calibration error
Used by: PDW
Cause: The calibration plate was not recognized correctly.
Remedy: Check that the calibration plate image has been acquired correctly.
------------------------------
Code: 230A2002
Display: Field of view out of range.
Used by: PDW
Cause: The field of view has exceeded the target area for image recognition.
Remedy: Reduce the field of view and carry out calibration again.
------------------------------
Code: 230A2003
Display: Cannot edit.
Used by: PDW
Cause: Failed to enlarge the image because the unit value is invalid.
Remedy: Carry out calibration again.
------------------------------
Code: 230A2004
Display: Adjustment failed.
Used by: PDW
Cause: Failed to set the shutter speed necessary for the specified brightness.
Remedy: Check that there is an image displayed with the brightness adjusted within the correct range,
then carry out the adjustment again.
------------------------------
第 2177 页
Code: 230A2005
Display: Cannot image-edit.
Used by: PDW
Cause: An error occurred when starting lEditor.exe.
Remedy: Confirm that the lEditor.exe file exists.
------------------------------
Code: 230A3100
Display: 找不到文件
Used by: PDW,GPX,NXTP
Cause: 在设定查找线时,所需的文件有可能破坏了而没有找到。
Remedy: 请重新安装PDW。 请重新编辑和修正定位点形状。(GPX,NXTP)
------------------------------
Code: 230A3101
Display: Maximum input level reached.
Used by: PDW
Cause: You attempted to set over ten points in the shape data during shape editing.
Remedy: Delete the existing shape data and set new shape data.
------------------------------
Code: 230A3102
Display: Maximum input level reached.
Used by: PDW
Cause: You attempted to set over 30 points on the fold line.
Remedy: Set 30 or fewer points on the fold lines.
------------------------------
Code: 230A3103
Display: Pitch measurement error.
Used by: PDW
Cause: Failed to measure the pitch when the template file was compiled.
Remedy: Reset the seek lines.
------------------------------
Code: 230A3104
Display: Edge position compensation cannot be performed because either there are no\nseek lines or none
of the seek lines has an edge.
Used by: PDW
Cause: The brightness deviation cannot be calculated because none of the seek lines have any edge flags
set.
Remedy: Set edge detection for at least one of the seek lines.
------------------------------
Code: 230A3105
Display: Cannot re-edit.
Used by: PDW
Cause: Either the template file is corrupt, or the image file cannot be found.
Remedy: Create the template again.
------------------------------
Code: 230A3106
Display: A Find seek line is necessary.
Used by: PDW
Cause: A Find must be specified for the template to be created, but none have been set.
Remedy: Compensate the position of the edges, or set a Find for some of the seek lines.
------------------------------
Code: 230A3107
第 2178 页