Used by: QP3OF Cause: A timeout error occurred while raising/lowering the tool changer. Remedy: Check that the tool changer is not interfering with any other part of the machine. ------------------------------ Code: 1205…
Make sure that the forward end and retract end sensors (X03C and X03D) turn on when the cylinder
moves.
------------------------------
Code: 12054044
Display: Air Cylinder Cycle Alarm Cleaner Wiper
Used by:
Cause: Wiper operation is incorrect.
Remedy: The wiper's forward and retract sensors may be faulty. Adjust or replace the sensors.
------------------------------
Code: 12054045
Display: "Cycle alarm: squeegee separation pressure response"
Used by: GSP5,GP6
Cause: The pressure level has been reduced from printing pressure to squeegee separation pressure, but
the lower limit signal (X072:SQG PRES LO) has not turned on.
Remedy: Make sure the squeegee separation pressure has been properly set for the pressure
measurement amp (#2). Make sure that the pressure applied during printing is not lower than that
applied forsqueegee separation. Set a lower squeegee pressure value for squeegee separation than is used
when printing.
------------------------------
Code: 12054046
Display: "Tape cutter cylinder alarm"
Used by: CP652C
Cause: The tape cutter cylinder did not move up or down within the specified time.
Remedy: Perform an I/O check OUT operation to turn off cylinder stopper Y036, then make sure that the
cylinder moves up and down when the cam handle is turned or when cam axis inching is performed.When
the cylinder moves, make sure that the upper and lower limit sensors (X034 and X035) turn on If the
upper and lower limit sensors (X034 and X035) do not turn on even when the cylinder moves up and
down normally, adjust the sensors and such as needed.
------------------------------
Code: 12054047
Display: Cycle Alarm Cylinder Towel Feed UP/DOWN
Used by: GSP5,GP551,GP6,NXTP
Cause: The cleaner towel feed operation was not completed within the specified amount of time.
Remedy: Make sure that additional force is not being exerted on the towel feed operation.
------------------------------
Code: 12054048
Display: Cycle Alarm Cylinder Cleaner Shaft
Used by: GP6
Cause: There was no sensor input by the cleaner shaft advance/retract limit sensor within the specified
amount of time.
Remedy: Confirm that the cleaner shaft operation is working correctly.
------------------------------
Code: 1205404D
Display: Tool changer error
Used by: QP3OF
Cause: There is a possibility of interference between the tool changer and the holder.
Remedy: Raise the Z-axis to a position where it will not interfere with the tool changer and holder. Also,
open the [Position] ? [Toll Changer Position] screen from the [Main] screen to lower the tool changer.
------------------------------
Code: 1205404E
Display: Tool changer error
第 551 页
Used by: QP3OF
Cause: A timeout error occurred while raising/lowering the tool changer.
Remedy: Check that the tool changer is not interfering with any other part of the machine.
------------------------------
Code: 12054050
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054051
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054052
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054053
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054054
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054055
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054056
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054057
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
第 552 页
------------------------------
Code: 12054058
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12054059
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1205405A
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1205405B
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1205405C
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1205405D
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1205405E
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1205405F
Display: Abolished
Used by: QP132
Cause: Abolished
Remedy: Abolished
------------------------------