FUJI错误代码查询.pdf - 第278页

(The first number in ??? indicates the station number (in hexadecimal).) (The following two numbers indicate the device number in that station.) (For device numbers above 256, 256 is displayed.) Remedy: Check the next de…

100%1 / 5282
Remedy: Check the main and sub mark coordinates.
------------------------------
Code: 11C30001
Display: 11C30001
Used by: CP7,QP3,NP1,NP2
Cause: More than one 2Dmark exists in Board.
Remedy: Check the 2Dmark sequence in the Recipe.
------------------------------
Code: 11C30002
Display: 11C30002
Used by: CP7,QP3,NP1,NP2
Cause: The Panel ID or the Board ID which is referred to by this sequence
is not in the production program, or has been skipped.
Remedy: Change the 2Dmark sequence before the placement sequence.
------------------------------
Code: 11CE0???
Display: 11CE0???(QP1)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The module number for the specified sequence is out of range.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Input a module number which is within the specified range.
------------------------------
Code: 11CE1???
Display: 11CE1???(QP1)
Used by: QP132
Cause: The module number for the specified sequence is out of range.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Either specify 105. Working Module in Proper data or change the module number.
------------------------------
Code: 11D00???
Display: 11D00???
Used by:
Cause: A device number is out of range. This error also occurs if device numbers used by the MTU1 are
set even though the machine is not equipped with an MTU1.
(The first number in ??? indicates the station number (in hexadecimal).)
(The following two numbers indicate the device number in that station.)
(For device numbers above 256, 256 is displayed.)
Remedy: Change the number of the devices which are located on the MFU.
Specify correct data for D in the production program's N_data.
If the machine is equipped with an MTU1, change Machine_Status B in Proper data (for the FIP3 and FLT)
as follows:
Machine_Status B: **** **** **** 1*** (MTU1),
Machine_Status B: **** **** ***1 **** (MTU2).
The data represented by * should not be changed from its present setting.(FIP3,FLT)
------------------------------
Code: 11D06???
Display: 11D06???
Used by: CP4-1,CP4-2,CP4-3,QP242,QP201,QP202,QP203,QP132
Cause: There is an unspecified next device in the next device loop.
第 277 页
(The first number in ??? indicates the station number (in hexadecimal).)
(The following two numbers indicate the device number in that station.)
(For device numbers above 256, 256 is displayed.)
Remedy: Check the next device loop of the appropriate device in the production program. Specify the
correct device number in Next.
------------------------------
Code: 11D08???
Display: 11D08???
Used by: CP4-1,CP4-2,CP4-3,QP242,QP201,QP202,QP203,QP132
Cause: The loop does not close even though the next device nest has exceeded 30 (12 for the QP132).
(The first number in ??? indicates the station number (in hexadecimal).)
(The following two numbers indicate the device number in that station.)
(For device numbers above 256, 256 is displayed.)
Remedy: Change Next in D_data so that the loop stops within 30 devices (within 12 for the QP132).
------------------------------
Code: 11D09???
Display: Same as code.
Used by: IP3,QP242,QP201
Cause: (IP3) The value set at the part data item "Scan_speed" is outside the permissible input range. If
this setting is larger than the value set at the Proper data items "233. Scan_speed_Camera1_BL" to "236.
Scan_speed_Camera1_FL", a transmission error occurs.
(QP242,QP201) The value set at the part data item "Scan_speed" is outside the permissible input range. If
this setting is larger than the value set at 28.8%, a transmission error occurs.
(The first "?" represents the station number and the following "??" represent the device number within the
station. The numbering is hexadecimal. For device numbers higher than 256, subtract 256.)
Remedy: Re-transmit the production program after the settings have been changed.
------------------------------
Code: 11D0A???
Display: Same as Code.
Used by: QP132
Cause: The specified number's device comment is not set. This setting must be set on the QP-132.
(The first "?" of the "???" represents the module number and the following "??" represent the device within
the module. The numbers are in hexadecimal format. If the device number is greater than 256, subtract
256.)
Remedy: Set the device comment.
------------------------------
Code: 11D0B???
Display: Same as code.
Used by: QP201,QP202,QP203
Cause: (APL,LCPM)A device number for dummy parts does not exist or has been incorrectly specified.
(CTL)Next device setting have been made.
(SPM)A device number for heat spreader parts does not exist or has been incorrectly specified.
(SRM) A next device number does not exist or has been incorrec tly specified.
(The first "?" represents the station number and the following "??" represent the device number within the
station. The numbering is hexadecimal. For device numbers higher than 256, subtract 256.)
Remedy: (APL,LCPM)Enter a valid device number for dummy parts.
(CTL)Delete the next device settings.
(SPM(CSF)) Specify the next device loop as: D102 ⅹ D111 ⅹ D112 ⅹ D113 ⅹ D114 ⅹ D102.
(SPM(Tray),SRM) Specify the next device as 101.
------------------------------
Code: 11D0C???
第 278 页
Display: Same as code.
Used by: QP201,QP202,QP202
Cause: The placement device number is an odd number.
(The first "?" represents the station number and the following "??" represent the device number within the
station. The numbering is hexadecimal. For device numbers higher than 256, subtract 256.)
Remedy: Enter an even number for the placement device number.
------------------------------
Code: 11D0D???
Display: Same as code
Used by: QP202
Cause: The settings for the rotation of the Q-axis are outside the acceptable range.
(The first "?" represents the station number and the following "??" represent the device number within the
station. The numbering is hexadecimal. For device numbers higher than 256, subtract 256.)
Remedy: Check the settings at "prog_polarity" (program header), "pd_polarity" (device data),
"parts_pickup_Q" - "direction" (part data) and "Q" in sequence data.
------------------------------
Code: 11D10???
Display: 11D10???
Used by: CP652C
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Cause: A part height (Component_height) which is specified in the part data is incorrect.
Remedy: Change the part data height to match the height of the actual part being used, and then
retransmit the program.
------------------------------
Code: 11D20???
Display: 11D20???
Used by: CP652C
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Cause: Index_Speed_CP5 (Cam_speed_CP4 on the FCP4) in part data is set to 0.
Remedy: After specifying an appropriate value for the device being used, retransmit the program.
------------------------------
Code: 11D21???
Display: 11D21???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by:
Cause: The nozzle over strokes because the specified pressure is too high. (Common) The placing
pressure (gf) which is specified in part data exceeds the valid range. When a part is placed, the amount of
negative movement (that is, movement past the point of placement) should be greater than 0.5 mm and
less than 2.5 mm. The placing pressure specified here results in this movement being exceeded (FIP3).
Remedy: In part data, specify a nozzle with a strong spring force and reduce the amount of placing
pressure. Adjust the position of the placing pressure sensor. (Common) Change the specified placing
pressure value or change the nozzle which is used with the pressure control function (FIP3).
------------------------------
Code: 11D22???
Display: 11D22???
第 279 页