Code: 11100126 Display: Production program check alarm Used by: QP3 Cause: An STU9 has been specified for SIDE 1. Remedy: An STU9 cannot be used on SIDE 1, Specify an appropriate device type. ----------------------------…
Cause: Data exists in production program for side that has no part supply position.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 1110011E
Display: Production program check alarm
Used by: NP2,QP3
Cause: Specified cavity number exceeds the tray dimensions.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 1110011F
Display: Production program check alarm
Used by: NP2,QP3
Cause: Invalid data for pin check mode exists.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100120
Display: Production program check alarm
Used by: NP2,QP3
Cause: Light setting for pin check mode is incorrect.
If "Cut" is specified : Do not use frontlight.
If "Mark" or "Bump" is specified : Do not use backlight.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100121
Display: Simultaneous mark reading error
Used by: NP-2, QP-3
Cause: Simultaneous reading of unsuitable marks was specified in the production program. Marks
should be read one at a time.
Remedy: Change the settings in the program. Mark sequences within the parameter area cannot be read
simultaneously.
------------------------------
Code: 11100122
Display: Production program check alarm
Used by: NP2,QP3
Cause: Tape feed pitch is not set to (a) motor feeder.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100124
Display: Production program check alarm
Used by: QP3
Cause: Although the CCGA Mark Check item has been set to YES(1), the Pin Check Mode has not been
set to MARK(5) or BUMP(6).
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100125
Display: Production program check alarm
Used by: QP3
Cause: The feeder type has not been set to "Tray" for the STU.
Remedy: Only trays can be supplied to STUs. When using an STU, the feeder type must be set to "Tray".
When not using an STU, specify an appropriate feeder type.
------------------------------
第 231 页
Code: 11100126
Display: Production program check alarm
Used by: QP3
Cause: An STU9 has been specified for SIDE 1.
Remedy: An STU9 cannot be used on SIDE 1, Specify an appropriate device type.
------------------------------
Code: 11100127
Display: Production program data mismatch
Machine type: all PCC machines
Used by:
Cause: A Panel ID/Board ID exists in the sequence, but the Panel ID/Board ID data does not exist.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110012A
Display: Production program check error
Machine type: QP3
Used by:
Cause: Parts with the package type set to "Tray" have been allocated to a MFU/PFU but no STU has been
assigned.
Remedy: Assign an STU for Feeder Name (F4G: Feeder Spec Name) or, when the STU is not being used
with the MFU/PFU, do not assign a tray for the package type.
------------------------------
Code: 1110012B
Display: Production program check error
Machine type: QP3
Used by:
Cause: Insertion control has been specified in the production program, however this function is not used
on this machine.
Remedy: Upgrade the servo control software to a version supporting SERCOS interface torque control in
order to use the insertion control function. Specify normal surface placement in the program if not using
insertion control.
------------------------------
Code: 11100130
Display: Production program data mismatch
Machine type: QP3
Used by:
Cause: There is an error in the mark specification that prevents placement offset based on 2 marks.
Placement offset cannot be calculated because the main mark and sub mark are in the same position.
Remedy: Specify fiducial marks with different positions for the main mark and sub mark.
------------------------------
Code: 11100131
Display: Production program error.
Used by: QP3
Cause: A placing sequence coordinate is out of range.
Remedy: Set the Y-direction placing coordinate within the maximum board width.
The final Y placing coordinate is calculated at [Location Y] of sequence data by adding [Machine
origin and program origin offset Y (Ya)] in the program header and [Place-Offset Y] in part data.
If the [Location Y] setting is correct, check to see if an incorrect offset has been set.
------------------------------
Code: 11100132
Display: Production program data mismatch.
第 232 页
Used by: QP3
Cause: There is an error is the order of the skip mark sequence.
Remedy: Check that no board skip marks (GS, Gr marks) are set ahead of the skip mark for board 0.
Check that a Gr mark sequence is not set ahead of a global skip mark sequence.
------------------------------
Code: 11100133
Display: Production program data mismatch.
Used by: QP3
Cause: An MTU is used, but the package type is not tray.
Remedy: When using an MTU, change the package type to tray.
------------------------------
Code: 11100201
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open machine calibration data file. All data items have been reset to their default values.
Remedy: Remeasure calibration data, or use the [Data Editor] command to edit the required items, and
use the [System Backup] command to save the changes.
Alternatively, download an uncorrupted calibration data file and load it using the [Restore System]
command.
------------------------------
Code: 11100202
Display: File save error!
Used by: NP2,QP3
Cause: Failed to write the machine calibration data file to the hard disk.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100203
Display: File creation error!
Used by: NP2,QP3
Cause: Failed to create a new machine calibration data file.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100204
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the machine calibration data file is too old. All data items have been reset to their
default values.
Remedy: Remeasure calibration data, or use the [Data Editor] command to edit the required items, and
use the [System Backup] command to save the changes.
This will cause the revision file to be renewed automatically.
------------------------------
Code: 11100205
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the machine calibration data file is too new. All data items have been reset to their
default values.
Remedy: Upgrade the system software.
Alternatively, download an old revision calibration data file and load it using the [Restore System]
command.
------------------------------