FUJI错误代码查询.pdf - 第1943页

Code: 2100752B Display: Part data read error Used by: Cause: Unable to read Part data. Remedy: Check the file. ------------------------------ Code: 2100752C Display: File read error Used by: Cause: Unable to read input f…

100%1 / 5282
Remedy: If the machine type is correct, re-install the software.
------------------------------
Code: 21007523
Display: Index file open error
Used by:
Cause: Unable to open the index file.
Remedy: Re-install the software.
------------------------------
Code: 21007524
Display: Strategy file get error
Used by:
Cause: Unable to read the system (strategy) file.
Remedy: Re-install the software.
------------------------------
Code: 21007525
Display: Make not mark sequence
Used by:
Cause: A mark sequence was not created.
Remedy: This message occurs when there is a program without a mark sequence.
------------------------------
Code: 21007526
Display: Station over
Used by:
Cause: The device could not be placed on the station.
Remedy: Join the feeder. Alternately, stop using the PST and the base program.
------------------------------
Code: 21007527
Display: Occupancy error
Used by:
Cause: An attempt was made to place a fixed device where it could not be placed.
Remedy: Depending on the feeder width, there are cases where the feeders cannot be placed next to each
other. Change the location.
------------------------------
Code: 21007528
Display: Slot info read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 21007529
Display: Occupancy data not found
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100752A
Display: Part data open error
Used by:
Cause: Unable to open Part data.
Remedy: Check the file.
------------------------------
第 1942 页
Code: 2100752B
Display: Part data read error
Used by:
Cause: Unable to read Part data.
Remedy: Check the file.
------------------------------
Code: 2100752C
Display: File read error
Used by:
Cause: Unable to read input file.
Remedy: Check the file.
------------------------------
Code: 2100752D
Display: File offset get error
Used by:
Cause: Unable to read the input file.
Remedy: Check the file and save the changes.
------------------------------
Code: 2100752E
Display: Can not feedback Fix device
Used by:
Cause: The specified device number for the fixed device is wrong.
Remedy: Check the PST file device numbers.
------------------------------
Code: 2100752F
Display: Skip device station over
Used by:
Cause: Unable to mount skip device.
Remedy: There are too many devices, so the skip device cannot be mounted. Reduce the number of
devices.
------------------------------
Code: 21007530
Display: Next device station over
Used by:
Cause: Unable to mount next device.
Remedy: There are too many devices, so the next device cannot be mounted. Reduce the number of
devices.
------------------------------
Code: 21007531
Display: New prodction file has no sequence data
Used by:
Cause: The new production program has no sequence data.
Remedy: Check the program's sequence data.
------------------------------
Code: 21007532
Display: Input program file name is too long
Used by:
Cause: Input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007533
第 1943 页
Display: Output program file name is too long.
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007534
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 21007535
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 21007536
Display: "No entry Machine name"
Used by:
Cause: A machine name has not been entered in the "Sep_data" section of the Part data.
Remedy: Enter a machine name and a feeder name in the "Sep_data" section of the Part data.
------------------------------
Code: 21007537
Display: "Couldn*t separate on St.2"
Used by:
Cause: An error occurred as the result of an attempt to allocate a component having a size smaller than
7 mm to Station 2.
Remedy: Components smaller than 7 mm cannot be allocated to Station 2. Specify this component for
fixed allocation to Station 1.
------------------------------
Code: 21007538
Display: "Not PST file"
Used by:
Cause: A file that has been specified as a PST file does not have the ".pst" extension.
Remedy: Specify a PST file as the permanent set table.
------------------------------
Code: 21007539
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100753A
Display: "Can not use cartridge type"
Used by:
Cause: An attempt was made to allocate a fixed feeder as specified by the device comment in question,
but an error occurred when the feeder was checked against the usable feeder types.
Remedy: Change the feeder type in the PST file to one that can be used by the station where the feeder is
specified as fixed.
------------------------------
第 1944 页