FUJI错误代码查询.pdf - 第1762页
Used by: Cause: The part was tilted more than 45 deg. and processing was therefore cancelled. Remedy: Check that the picking conditions have not gone bad. ------------------------------ Code: 1D650007 Display: Used by: C…
Code: 1D43D080
Display: Same as code.
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D43D100
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D43E???
Display: Same as code.
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions. In particular, check for soiling of the nozzle, and make sure that the
CCD level is correct.
------------------------------
Code: 1D43F???
Display: Same as code.
Used by:
Cause: There is a logical error in the processing program. The part cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the part.
Remedy: Check the Part data.
------------------------------
Code: 1D650001
Display:
Used by:
Cause: A range error occurred during vision processing.
Remedy: A range error occurs when a check is performed on a part but the check point is not on the
image. This could be caused by
1) a large part being picked incorrectly, resulting in an incomplete image;
2) an incorrect CCD level setting or broken nozzle, resulting in a bad image;
3) an incorrect value entered in Part data (PDG) so that vision processing could not be done;
4) the Proper values CCD_X and CCD_Y are incorrect, resulting in a bad image;
5) a problem with the vision processing system program. Check the above listed conditions.
------------------------------
Code: 1D650002
Display:
Used by:
Cause: The part could not be found.
Remedy: Check the condition of the part feeding system. Check the CCD level and the nozzle sizes
entered in Proper data. When using a 1608 part S nozzle (1.00 mm) check whether or not the normal size
(1.3mm) is entered. If this is the case and a 1608 part is picked, vision processing might register this as
not a part. If the CCD level is too high, the image will be too dark, and vision processing might register
this as not a part.
------------------------------
Code: 1D650006
Display:
第 1761 页
Used by:
Cause: The part was tilted more than 45 deg. and processing was therefore cancelled.
Remedy: Check that the picking conditions have not gone bad.
------------------------------
Code: 1D650007
Display:
Used by:
Cause: A range error occurred during vision processing.
Remedy: None.
------------------------------
Code: 1D650008
Display:
Used by:
Cause: The lead information in Part data (PDG) was checked, and there are not more than two leads on
the appropriate side.
Remedy: Check the following items in PDG: number of leads, lead information and the orientation of the
parts on the feeder.
------------------------------
Code: 1D650009
Display:
Used by:
Cause: A range error occurred during vision processing, and the processing was cancelled.
Remedy: A range error occurs when a check is performed on a part but the check point is not on the
image. This could be caused by
1) a large part being picked incorrectly, resulting in an incomplete image;
2) an incorrect CCD level setting or broken nozzle, resulting in a bad image;
3) an incorrect value entered in Part data (PDG) so that vision processing could not be done;
4) the Proper values CCD_X and CCD_Y are incorrect, resulting in a bad image;
5) a problem with the vision processing system program. Check the above listed conditions.
------------------------------
Code: 1D65000A
Display: 0010
Used by:
Cause: A range error occurred during vision processing, and the processing was cancelled.
Remedy: A range error occurs when a check is performed on a part but the check point is not on the
image. This could be caused by
1) a large part being picked incorrectly, resulting in an incomplete image;
2) an incorrect CCD level setting or broken nozzle, resulting in a bad image;
3) an incorrect value entered in Part data (PDG) so that vision processing could not be done;
4) the Proper values CCD_X and CCD_Y are incorrect, resulting in a bad image;
5) a problem with the vision processing system program. Check the above listed conditions.
------------------------------
Code: 1D65000B
Display: 0011
Used by:
Cause: The first lead could not be found during vision processing. A range error occurred during vision
processing, and the processing was cancelled.
Remedy: A range error occurs when a check is performed on a part but the check point is not on the
image. This could be caused by
1) a large part being picked incorrectly, resulting in an incomplete image;
2) an incorrect CCD level setting or broken nozzle, resulting in a bad image;
第 1762 页
3) an incorrect value entered in Part data (PDG) so that vision processing could not be done;
4) the Proper values CCD_X and CCD_Y are incorrect, resulting in a bad image;
5) a problem with the vision processing system program. Check the above listed conditions.
------------------------------
Code: 1D65000C
Display: 0012
Used by:
Cause: The first lead could not be found during vision processing.
Remedy: Check that the part pickup conditions were OK.
------------------------------
Code: 1D65000D
Display: 0013
Used by:
Cause: Either the bright space exceeded the lead pitch by 50% or the dark space exceeded the lead width
by 50%. The dark space represents the actual lead width.
Remedy: Check the entries in Part data (PDG) for lead width, lead pitch and check the CCD level.
------------------------------
Code: 1D65000E
Display: 0014
Used by:
Cause: The calculations of the lead locations on a leadless IC resulted in a range error.
Remedy: Calculate the leadless part at the PDG pitch item. Check the PDG lead pitch, lead information,
direction, and the orientation in which the parts are set on the machine.
------------------------------
Code: 1D65000F
Display: 0015
Used by:
Cause: Either the bright space exceeded the lead pitch by 50% or the dark space exceeded the lead width
by 50%. The dark space represents the actual lead width.
Remedy: Check the entries in Part data (PDG) for lead width, lead pitch and check the CCD level. The
Pitch limit item is entered in percentage points. An entry of 0 will give a default of 30%.
------------------------------
Code: 1D650010
Display: 0016
Used by:
Cause: The first lead could not be found during vision processing. A range error occurred during vision
processing, and the processing was cancelled.
Remedy: A range error occurs when a check is performed on a part but the check point is not on the
image. This could be caused by
1) a large part being picked incorrectly, resulting in an incomplete image;
2) an incorrect CCD level setting or broken nozzle, resulting in a bad image;
3) an incorrect value entered in Part data (PDG) so that vision processing could not be done;
4) the Proper values CCD_X and CCD_Y are incorrect, resulting in a bad image;
5) a problem with the vision processing system program. Check the above listed conditions.
------------------------------
Code: 1D650011
Display: 0017
Used by:
Cause: A range error occurred while checking for the ends of the leads.
Remedy: Check the Part data (PDG) lead length, pickup point, and the vision processing conditions.
------------------------------
第 1763 页