FUJI错误代码查询.pdf - 第899页

Display: Movement interpolation error. Used by: Cause: Movement interpolation has occurred for the same axis. Remedy: Reinstall the software, because the initial installation could have failed. --------------------------…

100%1 / 5282
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 12200076
Display: Axis movement processing error.
Used by:
Cause: During axis movement, another process occurred.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 12200077
Display: Servo parameter error.
Used by:
Cause: Failed to set a parameter on the servo controller board.
Remedy: Reinstall the software, because the initial installation could have failed.
Replace servo controller board with a new one if no abnormalities are found, because the servo
controller board could be damaged.
------------------------------
Code: 12200078
Display: Servo parameter error.
Used by:
Cause: Failed to acquire a servo parameter from the servo controller board.
Remedy: Reinstall the software, because the initial installation could have failed.
Replace servo controller board with a new one if no abnormalities are found, because the servo
controller board could be damaged.
------------------------------
Code: 12200079
Display: Compare position registration error.
Used by:
Cause: The specified compare position object is not registered.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 1220007a
Display: SERCOS communication error.
Used by:
Cause: An error occurred during SERCOS communication.
Remedy: Ensure that the digital operator is not connected to an amplifier.
Replace SERCOS drive with a new one if no abnormalities are found, because the SERCOS drive
board could be damaged.
------------------------------
Code: 1220007b
Display: Machine type error.
Used by:
Cause: This function can only be called in a machine with an analog environment.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 1220007c
Display: Machine type error.
Used by:
Cause: This function can only be called in a machine with an SERCOS environment.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 1220007d
第 898 页
Display: Movement interpolation error.
Used by:
Cause: Movement interpolation has occurred for the same axis.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 1220007e
Display: Movement interpolation error.
Used by:
Cause: For the selected axes, movement interpolation cannot be be done because the axes are not on the
same servo controller board.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 1220007f
Display: Process error.
Used by:
Cause: A function only supported by the RTX process was called.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 12200080
Display: Process error.
Used by:
Cause: A function only supported by the Win32 process was called.
Remedy: Reinstall the software, because the initial installation could have failed.
------------------------------
Code: 12200081
Display: Axes stop demand.
Used by:
Cause: The axis movement was stopped by the application.
Remedy: Remove the cause of the error and resume operation.
------------------------------
Code: 12200085
Display: Servo amplifier error.
Used by:
Cause: Positioning deviation pulse between motor encooder and linear encooder was over the set value.
Remedy: Check to ensure that the deviation setting is appropriate.
Check for breaks in the encoder wiring, or for bad connections.
------------------------------
Code: 12201001
Display: Command error.
Used by:
Cause: A command which can not be recognized was send to the conveyor control board.
Remedy: Replace conveyor control board with a new one if no abnormalities are found, because the
conveyor control board could be damaged.
------------------------------
Code: 12201002
Display: Data error.
Used by:
Cause: Incorrect data was send to the conveyor control board.
Remedy: Replace conveyor control board with a new one if no abnormalities are found, because the
conveyor control board could be damaged.
------------------------------
第 899 页
Code: 12201003
Display: CRC error.
Used by:
Cause: An error has occurred during communication.
Remedy: Replace conveyor control board with a new one if no abnormalities are found, because the
conveyor control board could be damaged.
------------------------------
Code: 12201004
Display: Cover opening.
Used by:
Cause: Conveyor's cover is open.
Remedy: Close a conveyor's cover.
------------------------------
Code: 12201005
Display: Emergency Stop.
Used by:
Cause: The emergency stop button was pressed.
Remedy: Reset the emergency stop button.
------------------------------
Code: 12201006
Display: Encoder error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 2.8 V.
Remedy: There is possibility that the position data of the encoder disappeared.
------------------------------
Code: 12201007
Display: Battery error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 3.0 V.
Remedy: Exchange a battery of the encoder for the backup.
------------------------------
Code: 12201009
Display: Conveyor's width error.
Used by:
Cause: The software limit of Conveyor's width is over.
Remedy: After confirming a maximum and a minimum value, input once more.
------------------------------
Code: 1220100A
Display: Movement error.
Used by:
Cause: The operation didn't end normally by some factor.
Remedy: After removing an extraordinary factor, operation be resumed.
------------------------------
Code: 1220100B
Display: Communication error.
Used by:
Cause: Communication between the host and the conveyor control board wasn't established in the time.
Remedy: Replace conveyor control board with a new one if no abnormalities are found, because the
conveyor control board could be damaged.
------------------------------
Code: 12201014
第 900 页