FUJI错误代码查询.pdf - 第716页

Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Y-drct pickup tol.error"(QP2) Used by: QP242 Cause: The amount of pick up misalignment has exceeded the value specified at the part data item, &quo…

100%1 / 5282
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because the PMC is busy.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?07
Display: "ICM (PMC?, SCU?) Error code: ********" (QP-2)
"Unexecutable(Axis Moving)" (QP2)
"Processing: Cannot execute"(QP132)
PM?? ERROR Code: ******** (QP-132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because the axis is moving.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?08
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Holding Parts" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because the nozzle is holding a component.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, then use commands to dump parts. If the problem
occurs again, use a reset-start to transmit the control software to the PMCs. If the problem is recurring,
issues such as a faulty PMC control board may be the cause.
------------------------------
Code: 12070?09
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Chuck" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no chuck.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?0A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"X-drct pickup tol.error"(QP2)
Used by: QP242
Cause: The amount of pick up misalignment has exceeded the value specified at the part data item,
"Tolerance Pickup X ??".
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the way the part is picked up or check the validity of part data setting.
------------------------------
Code: 12070?0B
第 715 页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Y-drct pickup tol.error"(QP2)
Used by: QP242
Cause: The amount of pick up misalignment has exceeded the value specified at the part data item,
"Tolerance Pickup Y ??".
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the way the part is picked up or check the validity of part data setting.
------------------------------
Code: 12070?0C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Q-drct pickup tol.error"(QP2)
Used by: QP242
Cause: The amount of pick up misalignment has exceeded the value specified at the part data item,
"Tolerance Pickup Q ??".
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the way the part is picked up or check the validity of part data setting.
------------------------------
Code: 12070?0D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Raised part error" (QP2)
Used by: QP201 (APL)
Cause: Parts are not correctly positioned in the carrier pockets.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Check the positioning of the parts in the pockets. Check the settings for use of the raised part
detection sensor.
------------------------------
Code: 12070?10
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Connect Req Not Permitted" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Connection requests from the port in question are not permitted.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?11
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Relevant Device Number" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command contains data for which there is no corresponding device number.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the device numbers in the production program. Retransmit the program and restart the
machine. If the problem occurs again, use a reset-start to transmit the control software to the PMC. If the
problem is recurring, issues such as a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?12
第 716 页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Data Out of Range" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command contains data outside the valid range.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?13
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Servo Driver Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A servo driver error has occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?14
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Servo Controller Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A servo controller error has occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?15
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
"Exceeded acceptable inching range for the Q-axis" (QP2)
Used by: QP202,QP203
Cause: The acceptable inching range for the Q-axis has been exceeded.
Remedy: Correct the angle of the Q-axis by up to +-15 deg..
------------------------------
Code: 12070?16
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Manual" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because the machine is operating in manual mode.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
第 717 页