FUJI错误代码查询.pdf - 第515页
Code: 12050427 Display: Consecutive defective carrier error Used by: QP301 Cause: The number of consecutive carriers for which an error was recorded has exceeded the specified limit. Remedy: Check the condition of the pa…
Display: Scan area error
Used by: NP2,QP3
Cause: Either the scan area exceeds 81.92mm in both the X and Y directions, or the frame size exceeds
4MB.
Remedy: Specify a scan area which is suitable for the size of the part in question. If the scan area is
specified as "0", the scan area is determined automatically.
------------------------------
Code: 12050420
Display: PFU docking error!
Used by: NP2,QP3
Cause: The PFU is not attached.
Remedy: Check if the PFU is correctly attached to the machine.
------------------------------
Code: 12050421
Display: Connection error for parts supply unit.
Used by: NP2,QP3
Cause: The input for the parts supply unit at the stage displayed in the parameter section switched off.
Remedy: Check if the parts supply unit has been correctly set.
------------------------------
Code: 12050422
Display: LON communication error!
Used by: NP2,QP3
Cause: LON communication error!
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 12050423
Display: Nozzle settings error!
Used by: NP2,QP3
Cause: The required nozzle is not located in the position specified in nozzle settings.
Remedy: Check nozzle memory.
------------------------------
Code: 12050424
Display: Tray eject error!
Used by: NP2,QP3
Cause: The tray remover may be holding a tray.
Remedy: If the tray remover is holding a tray, remove tray. Alternatively turn the vacuum supply to the
tray remover off.
------------------------------
Code: 12050425
Display: MTU shuttle speed setting error
Used by: NP2,QP3
Cause: MTU slot information cannot be set.
Remedy: Re-specify the production program, then re-specify the MTU slot information.
------------------------------
Code: 12050426
Display: SOOP checking error!
Used by: QP301
Cause: A raised part was detected.
Remedy: Check the condition of the parts on the FOL carrier.
------------------------------
第 514 页
Code: 12050427
Display: Consecutive defective carrier error
Used by: QP301
Cause: The number of consecutive carriers for which an error was recorded has exceeded the specified
limit.
Remedy: Check the condition of the parts on the FOL carrier.
------------------------------
Code: 12050428
Display: Defective package count error
Used by: QP301
Cause: The number of packages for which an error was recorded has exceeded the specified limit.
Remedy: Check the condition of the parts on the FOL carrier.
------------------------------
Code: 12050429
Display: SOOP Data Collection Error!
Used by: QP301
Cause: A communication error occurred between the Machine and amp unit during the collection of
SOOP d ata.
Remedy: Cut the power to the machine and check the RS cable.
------------------------------
Code: 1205042A
Display: Temperature warning.
Used by: QP3
Cause: The heater temperature is outside the suitable range.
Remedy: Wait until the temperature settles.
------------------------------
Code: 1205042B
Display: Heater error.
Used by: QP3
Cause: The heater temperature is not correct. The temperature controller or sensor may be damaged.
Remedy: Cut the power to the machine and check the temperature controller and sensor.
------------------------------
Code: 1205042C
Display: Temperature warning.
Used by: QP3
Cause: Switching to single panel production as the heater temperature is outside the suitable range.
Remedy: Wait until the temperature settles, and then resume operation.
------------------------------
Code: 1205042D
Display: Temperature warning.
Used by: QP3
Cause: Cannot operate as the heater temperature is outside the suitable range.
Remedy: Start operation after the temperature has settled.
------------------------------
Code: 1205042E
Display: Pallet Setting Error
Used by: CP732E,CP742ME,CP742E,CP752E
Cause: Pallet clamping was unsuccessful.
Remedy: Check if the following sensor(s) is ON using I/O.
Stage1: X087 D1 PALLET SET CHECK FRONT
X088 D1 PALLET SET CHECK REAR
第 515 页
Stage2: X09D D2 PALLET SET CHECK FRONT
X09E D2 PALLET SET CHECK REAR
Check if there is any foreign matter underneath the pallet, or if the pallet is tilted.
------------------------------
Code: 1205042F
Display: Tool memory error
Used by: QP3OF
Cause: An unspecified tool exists on the holder.
Remedy: Remove the tool from the holder, or access the tool settings screen at the touch panel to specify
the tool that is attached to the holder.
------------------------------
Code: 12050430
Display: Tool memory error
Used by: QP3OF
Cause: The tool specified at the tool allocation screen is not attached to the holder.
Remedy: Attach the specified tool to the head, or remove the tool setting by opening the tool setttings
screen at the touch panel and changing the tool number to '0'.
------------------------------
Code: 12050431
Display: Tool memory error
Used by: QP3OF
Cause: An unspecified tool exists in a changer socket.
Remedy: Remove the tool if it is attached to the holder as there is the possibility of interference. If a tool
is not attached to the holder, firstly attach a tool to the holder, then open the tool settings screen at the
touch panel and set the holder tool number to '0'.
------------------------------
Code: 12050432
Display: Tool memory error
Used by: QP3OF
Cause: The tool specified at the tool allocation screen is not in the changer socket.
Remedy: Insert the specified tool into the socket, or remove the tool nickname setting at the toolsetttings
screen by changing the tool nickname for the socket to 'Empty'.
------------------------------
Code: 12050433
Display: Tool interference error
Used by: QP3OF
Cause: When performing tool ejection, there is a possibility of interference with another tool.
Remedy: At the touch panel, open the tool settings screen and specify a new position for the tool(s) so that
interference will not occur. Check that the tool nicknames are correct. If all tools are already in a safe
position when this error occurs, check that the tool changer nickname is correct.
------------------------------
Code: 12050434
Display: Tool interference error
Used by: QP3OF
Cause: When performing tool ejection, there is a possibility of interference with the parts camera lighting
unit.
Remedy: At the touch panel, open the tool settings screen and specify a new position for the tool(s) so that
interference will not occur. Check that the tool nicknames are correct. If all tools are already in a safe
position when this error occurs, check that the tool changer nickname is correct.
------------------------------
Code: 12050440
第 516 页