------------------------------ Code: 1D080009 Display: Used by: Cause: The lead is missing. Remedy: Check the number of leads, and check the orientation of the parts when they are fed to the machine. The lead has to have…
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D080003
Display:
Used by:
Cause: An image cannot be taken by vision processing. The part is too large.
Remedy: Check the camera, vision processing board, cable and focus. Check the part. The lead has to
have a certain thickness to be detected. If the lead thickness is not within +-50% of the thickness set in
Part data this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080004
Display:
Used by:
Cause: The part lead cannot be found.
Remedy: Check that the lead exists, and check the thickness of the lead. Check the part. The lead has to
have a certain thickness to be detected. If the lead thickness is not within +-50% of the thickness set in
Part data this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080005
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part data this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D080006
Display:
Used by:
Cause: No leads can be found.
Remedy: Check whether the lead exists, and check the orientation of the parts when they are fed to the
machine. The lead has to have a certain thickness to be detected. If the lead thickness is not within +-
50% of the thickness set in Part dat this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080007
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part data this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D080008
Display:
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch, and check the orientation of the parts when they are fed to the machine.
The lead has to have a certain thickness to be detected. If the lead thickness is not within +-50% of the
thickness set in Part dat this error can occur. Check the part lead and the CCD level.
第 1317 页
------------------------------
Code: 1D080009
Display:
Used by:
Cause: The lead is missing.
Remedy: Check the number of leads, and check the orientation of the parts when they are fed to the
machine. The lead has to have a certain thickness to be detected. If the lead thickness is not within +-
50% of the thickness set in Part dat this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D08000B
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000C
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000D
Display:
Used by:
Cause: The lead width is too long.
Remedy: Check the length of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000F
Display:
Used by:
Cause: Processing error.
Remedy: Check the part shape, and check whether or not the part exists.
------------------------------
Code: 1D080010
Display:
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the number of leads on the part. The lead has to have a certain
thickness to be detected. If the lead thickness is not within +-50% of the thickness set in Part dat this
error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080011
Display:
Used by:
Cause: The part tilt is too large.
第 1318 页
Remedy: Check the orientation of the parts when they are fed to the machine.
------------------------------
Code: 1D080012
Display:
Used by:
Cause: The opposing leads are too long. The body is too large.
Remedy: Check the size of the part. The lead has to have a certain thickness to be detected. If the lead
thickness is not within +-50% of the thickness set in Part data this error can occur. Check the part lead
and the CCD level.
------------------------------
Code: 1D088002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D088100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D088110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D088111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D088112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D088113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D088114
Display:
Used by: