Code: 1205040A Display: Pallet system error Used by: CP5 Cause: The pallet control software is defective. Remedy: Contact Fuji. ------------------------------ Code: 1205040B Display: 存在着无法读取定位点的顺序 [Mark seq. not processe…
Cause: MFU has not been set.
Remedy: Set the MFU.
------------------------------
Code: 12050404
Display: "Remove D1-3" (IP2)
Used by:
Cause: A tape feeder or stick feeder has been attached to D1, D2, or D3 on an FIP-series machine
equipped with an MTU.
Remedy: Remove tape feeders and stick feeders from D1, D2, and D3.
------------------------------
Code: 12050405
Display: "Thermal alarm" (GSP, GL, CP5), "PCM THERMAL Alarm" (CP651C)
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3,QP132
Cause: A servo motor thermal relay has been tripped.On the CP651C, an alarm has been detected by a
thermal relay on one of the following motors: UP elevator, DOWN elevator, or return conveyor.
Remedy: Make sure the servo axes are not overloaded. Inspect the connectors and wiring for motors and
servo amps. Press the thermal relay's reset button to cancel the error.
------------------------------
Code: 12050406
Display: Ready For Program NG
Used by:
Cause: A program has not been transmitted.
Remedy: Transmit a program from MCS.
------------------------------
Code: 12050407
Display: " 冷却装置警告 ", " Cooler Alarm "(GSP,GL)
Used by: GL2,GSP2,GSP3,GP2,GP3,GPX,NXTP
Cause: 超出了温调用的操作画面上所设定的温度调整的范围。
Remedy: 请确认温调用的开关是否开启。如果开关开启着,请检查加热器和冷却装置是否发生了异常,另外,温度调
整范围的设定是否正确。
<img src="$LKEY_ERRIMG_MC$/12050407.PNG">
------------------------------
Code: 12050408
Display: " 加热器警告 ", " Heater Alarm "(GSP,GL)
Used by: GL2,GSP2,GSP3,GP2,GP3,GPX,NXTP
Cause: 超出了温调用的操作画面上所设定的温度调整的范围。
Remedy: 请确认温调用的开关是否开启。如果开关开启着,请检查加热器和冷却装置是否发生了异常,另外,温度调
整范围的设定是否正确。
<img src="$LKEY_ERRIMG_MC$/12050408.PNG">
------------------------------
Code: 12050409
Display: "Zero Set NG"
Used by:
Cause: Zero setting has not been performed.
Remedy: Perform zero setting.If the machine has stopped part of the way through zero setting after the
START button is pressed, the display will indicate which axes have not been zeroed. Press
theEMERGENCY STOP button, turn off the power supply, and check the axes in question for
abnormalities. (Check the zero-setting sensors, motors, cables, and amps; check for mechanical
interference; etc.)
------------------------------
第 512 页
Code: 1205040A
Display: Pallet system error
Used by: CP5
Cause: The pallet control software is defective.
Remedy: Contact Fuji.
------------------------------
Code: 1205040B
Display: 存在着无法读取定位点的顺序
[Mark seq. not processed]
Used by: GP2,GP3,IP3,QP132,GPX,NXTP
Cause: 读取BadMark的时候,或者,没有读取在贴装元件时参照的基准定位点。 没有发现钢板的定位点。 (GPX)
Remedy: 发生在没有对应「自动重新读取定位点」的机型。请重新读取定位点。 1.请确认定位点是否弄脏。
2.请确认定位点形状或检索范围是否被正确设定了。(GPX)
<img src="$LKEY_ERRIMG_MC$/1205040B.PNG">
------------------------------
Code: 1205040C
Display: ST2 Parts chk sensor err.
Used by: CP-IV/IV-2(SMD3), CPIV-3/6/6M/642/65/652C
Cause: There is a sensor error at station 2, large part check.
This could be caused by misalignment of the light beam in the sensor, a broken wire leading to the sensor
part that emits the beam, or the entire sensor itself may be malfunctioning.
Remedy: If there is a problem with the alignment of the light beam, adjust the beam. If there is a problem
with the part of the sensor that emits the light beam, after determining the cause of the error, replace the
sensor, rewire the sensor, etc.
Additionally, check station 2 to verify that a part has been picked up, and examine the device feeder.
------------------------------
Code: 12050410
Display: I/O system error!
Used by: NP2,QP3
Cause: An error occurred in the I/O system.
Remedy: Restart the machine.
------------------------------
Code: 12050411
Display: MFU Proper data writing error
Used by: NP2,QP3
Cause: MFU Proper data writing failed.
Remedy: This is a LON communication error. Restart the machine.
------------------------------
Code: 12050412
Display: MTU Proper data writing error
Used by: NP2,QP3
Cause: MTU Proper data writing failed.
Remedy: This is a LON communication error. Restart the machine.
------------------------------
Code: 12050413
Display: PFU Proper data writing error
Used by: NP2,QP3
Cause: PFU Proper data writing failed.
Remedy: This is a LON communication error. Restart the machine.
------------------------------
Code: 12050414
第 513 页
Display: Scan area error
Used by: NP2,QP3
Cause: Either the scan area exceeds 81.92mm in both the X and Y directions, or the frame size exceeds
4MB.
Remedy: Specify a scan area which is suitable for the size of the part in question. If the scan area is
specified as "0", the scan area is determined automatically.
------------------------------
Code: 12050420
Display: PFU docking error!
Used by: NP2,QP3
Cause: The PFU is not attached.
Remedy: Check if the PFU is correctly attached to the machine.
------------------------------
Code: 12050421
Display: Connection error for parts supply unit.
Used by: NP2,QP3
Cause: The input for the parts supply unit at the stage displayed in the parameter section switched off.
Remedy: Check if the parts supply unit has been correctly set.
------------------------------
Code: 12050422
Display: LON communication error!
Used by: NP2,QP3
Cause: LON communication error!
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 12050423
Display: Nozzle settings error!
Used by: NP2,QP3
Cause: The required nozzle is not located in the position specified in nozzle settings.
Remedy: Check nozzle memory.
------------------------------
Code: 12050424
Display: Tray eject error!
Used by: NP2,QP3
Cause: The tray remover may be holding a tray.
Remedy: If the tray remover is holding a tray, remove tray. Alternatively turn the vacuum supply to the
tray remover off.
------------------------------
Code: 12050425
Display: MTU shuttle speed setting error
Used by: NP2,QP3
Cause: MTU slot information cannot be set.
Remedy: Re-specify the production program, then re-specify the MTU slot information.
------------------------------
Code: 12050426
Display: SOOP checking error!
Used by: QP301
Cause: A raised part was detected.
Remedy: Check the condition of the parts on the FOL carrier.
------------------------------