FUJI错误代码查询.pdf - 第762页

"PFU? [******]" Used by: QP132,NP132,NP133 Cause: A PFU waste tape cutter malfunction occurred during the cutting operation. (value replacing "?" is PFU number; command name appears in place of asteri…

100%1 / 5282
Display: PMC?? ERROR [Code:12072?04]
Used by: QP132
Cause: An error has been detected in PFU related data.
(value replacing "??" is module number)
Remedy: Attach the PFU to the machine, ensuring it is properly clamped. If the problem reoccurs after
clearing the error using the RESET button, or retransmitting the control software to the PMC using a
reset-start, there may be a problem such as a fault in the PFU to machine link board. Replace the
hardware in question, and if the problem still persists, output the PMC log and send it to Fuji for analysis.
------------------------------
Code: 12072?81
Display: "PFU command format error"
"PM?? [******]"
"Err Code: 12072?81"
Used by: QP132,NP132,NP133
Cause: A command format error occurred at a PFU related (other than the feeder) communication.
(value replacing "??" is module number; command name appears in place of asterisks.)
(value replacing "?" is module number.)
Remedy: If association was in progress, re-execute the association. If association was not in progress, re-
execute the operation which was in progress.
------------------------------
Code: 12072?82
Display: "PFU command response timeup"
"PM?? [******]"
"Err Code: 12072?82"
Used by: QP132,NP132,NP133
Cause: There was no response within the prescribed time period during a PFU related (other than the
feeder) communication.
(value replacing "??" is module number; command name appears in place of asterisks.)
(value replacing "?" is module number.)
Remedy: If association was in progress, re-execute the association. If association was not in progress, re-
execute the operation which was in progress.
------------------------------
Code: 12072?83
Display: "Waste tape box full"
"PFU? [******]"
Used by: QP132,NP132,NP133
Cause: The PFU waste tape box is full.
(value replacing "?" is PFU number; command name appears in place of asterisks.)
Remedy: Empty the PFU waste tape box. If this error is still displayed when the waste tape box is empty,
check the sensor.
------------------------------
Code: 12072?84
Display: "PFU cover open"
"PFU? [******]"
Used by: QP132,NP132,NP133
Cause: The PFU cover is open.
(value replacing "?" is PFU number; command name appears in place of asterisks.)
Remedy: Close the PFU cover. If this error is still displayed when the cover is closed, check the sensor.
------------------------------
Code: 12072?85
Display: "PFU cutter error"
第 761 页
"PFU? [******]"
Used by: QP132,NP132,NP133
Cause: A PFU waste tape cutter malfunction occurred during the cutting operation.
(value replacing "?" is PFU number; command name appears in place of asterisks.)
Remedy: Check the PFU waste tape cutter and the waste tape status.
------------------------------
Code: 12072?86
Display: "No KIT exist"
"PFU? [******]"
Used by: QP132
Cause: Although using KIT (optional kiting station) is designated in Proper Data, there is no KIT.
(value replacing "?" is PFU number; command name appears in place of asterisks.)
Remedy: Either connect KIT to the PFU, or change Proper Data KIT setting to "not used".
------------------------------
Code: 12072?87
Display: "Association time-out"
"PM?? [******]"
"Err Code: 12072?87"
Used by: QP132
Cause: Association could not be completed due to a missing command response during association
processing.
(value replacing "??" is module number; command name appears in place of asterisks.)
(value replacing "?" is module number.)
Remedy: Repeat the association processing.
------------------------------
Code: 12072?88
Display: "Tape cut request time-out"
"PM?? [******]"
"Err Code: 12072?88"
Used by: QP132
Cause: The response to a cut request (waste tape cutter) failed to occur within the prescribed period of
time.
(value replacing "??" is module number; command name appears in place of asterisks.)
(value replacing "?" is module number.)
Remedy: Verify that the PFU is connected to the machine. Also verify that use of the waste tape cutter is
designated in Proper Data.
------------------------------
Code: 12072?89
Display: "Out of Parts report time-up"
"PM?? [******]"
"Err Code: 12072?89"
Used by: QP132
Cause: KIT (optional kiting station) failed to respond to an "Out of Parts" report.
(value replacing "??" is module number; command name appears in place of asterisks.)
(value replacing "?" is module number.)
Remedy: Verify that KIT is connected to the PFU. If KIT is not being used, change Proper Data KIT setting
to "not used".
------------------------------
Code: 12072?8A
Display: Error status request reply timeout PM??[******]
Used by: QP132
第 762 页
Cause: The reply to an error status request command (for PFU) failed to arrive within the prescribed
period of time.
("?" is the module number expressed in hexadecimal code. "0" is PMC16.)
("??" is the module No. "******" is the command name.)
("?" is the module No.)
Remedy: Try the operation again in the same manner. Check to see if there is an association.
------------------------------
Code: 12072?8B
Display: The PFU status is BUSY.
PM?? [******]
Err Code: 12072?8B
Used by: QP132
Cause: The PFU is already carrying out association processing.
("?" indicates the module number in hexadecimal notation. PMC 16 displays as "0".)
("PM??" indicates the module number. "[******]" indicates the command.)
Remedy: Retry association if it is already being carried out. Retry the same kind of processing if
association is not being carried out.
------------------------------
Code: 12072?8D
Display: Auto operation report to PFU timed out.
PM?? [******]
Err Code: 12072?8D
Used by: QP132
Cause: The machine attempted to transmit an automatic operation report to the PFU, but failed to make
contact and the action timed out.
("?" indicates the module number in hexadecimal notation. PMC 16 displays as "0".)
("PM??" indicates the module number. "[******]" indicates the command.)
Remedy: Check if the PFU is properly attached to the machine.
------------------------------
Code: 12072?8E
Display: Feeder seting error.
PM?? [******]
Err Code: 12072?8E
Feeder setting error!(NP2,QP3)
Used by: QP132,NP2,QP3
Cause: An error was detected for a feeder used in the program.
("?" indicates the module number in hexadecimal notation. PMC 16 displays as "0".)
("PM??" indicates the module number. "[******]" indicates the command.)
A feeder setting error occurred.(NP2,QP3)
Remedy: Check whether the feeder is correcfly set.
Check if the feeder(s) in question have been correctly set.(NP2,QP3)
------------------------------
Code: 12073??1
Display: "PFU command format error"
"PM?? [******]"
"Err Code: 12073??1"
Used by: QP132
Cause: A command format error occurred at a PFU related (feeder related) communication.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
第 763 页